Cooling fans not coming on
Cooling fans not coming on
Author
Discussion

simonej

Original Poster:

5,513 posts

211 months

Tuesday 19th May 2009
quotequote all
Hi guys, got a bit of a problem with my cooling system. Driving in slow traffic the temperature climbed to 105 degrees so I pulled over and switched off. With the ignition on neither of the fans were switching on, in fact I only ever recall seeing one fan in operation recently (the left one).

Anyway, I've tried shorting the otter switch but nothing happens and the fans don't kick in. I've tried fiddling with the actual connections to the fans as well but to no avail. What else can I check or fiddle with before I start buying new bits or taking it to a professional? I'm actually still under warranty but I don't fancy driving the 40 miles to the garage again, especially as it involves some heavy traffic in places.

I don't know if it makes any difference but it's always done motorway cruising at 70 degrees and town at 92-ish but once I got it onto the motorway after it had cooled down it never got lower than 80.

Thanks. Simon.

selnic

467 posts

298 months

Tuesday 19th May 2009
quotequote all
Have you checked the 40amp(?) fuse in the fuse board?

simonej

Original Poster:

5,513 posts

211 months

Tuesday 19th May 2009
quotequote all
selnic said:
Have you checked the 40amp(?) fuse in the fuse board?
No I haven't. Where am I looking for that? (I'm a man whose 'Bible' hasn't arrived yet! biggrin)

Edited by simonej on Tuesday 19th May 17:52

selnic

467 posts

298 months

Tuesday 19th May 2009
quotequote all
Depending on what model year you have there should be either one or two fuses for the fans located on the main board behind the ECU, relays, battery rats nest area in the passenger foot well. If you are not sure which one is which , may be worth pulling out each one and checking it in turn. Fuses may blow due to excess load on the fan from coming on at high speed.
HTH
Selnic
(edited due to crap spelling)

Edited by selnic on Tuesday 19th May 17:59

simonej

Original Poster:

5,513 posts

211 months

Tuesday 19th May 2009
quotequote all
OK, slots 3 and 19 apparently. I'll take a look. One is for the horn also it says, so if that works would that mean the fuse is good?

selnic

467 posts

298 months

Tuesday 19th May 2009
quotequote all
Yes, logic is if the horn works, then the fues is ok (unless it is not wired in the usuall way) there may be a few differances between cars.

simonej

Original Poster:

5,513 posts

211 months

Tuesday 19th May 2009
quotequote all
OK, both fuses are good. I don't know much about relays but should I be checking those as well? If not, what else could be the matter. Tried shorting the otter switch again but nothing happens. frown

selnic

467 posts

298 months

Tuesday 19th May 2009
quotequote all
As you short the otter can you hear the relays clicking, if not worth pulling out and checking supply with a meter etc

GJOSDDLO

92 posts

211 months

Tuesday 19th May 2009
quotequote all
I'm sure you've already checked, but in the early models, very low water levels prevented the fan from coming on. Also check that there is no air in the water system.



Edited by GJOSDDLO on Tuesday 19th May 18:47

simonej

Original Poster:

5,513 posts

211 months

Tuesday 19th May 2009
quotequote all
GJOSDDLO said:
I'm sure you've already checked, but in the early models, very low water levels prevented the fan from coming on. Also check that there is no air in the water system.



Edited by GJOSDDLO on Tuesday 19th May 18:47
I have only checked the expansion tank which has a couple of inches in it. Is it possible to have water in the expansion tank but low levels in the header?

With regards to the relays there is no clicking at all when shorting the otter switch. I haven't the foggiest on how to test a relay and don't have the equipment either. Surely one of the pair would work though, the chances of two going wrong must be quite slim?

If the otter switch was completely dead would it still activate the fans when being shorted out?

selnic

467 posts

298 months

Tuesday 19th May 2009
quotequote all
How did you short the otter switch?

simonej

Original Poster:

5,513 posts

211 months

Tuesday 19th May 2009
quotequote all
Quinny said:
You should be able to just pull the 2 wires off the otter, join em up and the fans will run (ignition on) The wires don't need to be on the switch. Just hold em in your hand and stick a paper clip accross the wires

If this doesn't work my advice would be check ALL the fuses 1 after the other.


Does the horn work???

Edited by Quinny on Tuesday 19th May 19:00
OK, some progress. Horn works and after scratching some corrosion off the terminals for the otter switch I have now managed to get the left hand fan running at high speed with a paperclip.

Should both fans be running at this point? I only have the left one and as far as I can remember I haven't seen the right fan working before.

simonej

Original Poster:

5,513 posts

211 months

Tuesday 19th May 2009
quotequote all
....and another question......

Only Fan 1 is working (the left one anyway) and Fan 2 is not. Is it safe to connect the right hand fan to the power connection for the left hand fan to test it? The reason I ask is that after taking another look at the connectors, they're rather corroded on the right hand one.

Simon Says

19,466 posts

252 months

Tuesday 19th May 2009
quotequote all
Yes thats fine,try cleaning the connectors in the multiplug or better still cut them off and put on some new terminals i have never been able to salvage them rolleyes then cable tie them to the fan cowlings away from the channel at the bottom of the rad and easily inspected wink make sure both fans are sucking air while your at it one of mine was blowing scratchchin connected the wrong way round with the factory plugs fitted as per standard silly

Edited by Simon Says on Tuesday 19th May 19:33

selnic

467 posts

298 months

Tuesday 19th May 2009
quotequote all
First port of call would be to pull apart all the connectors on the fans, otter switch etc and clean them up till shiney metal can be seen on the contacts (use wire wool etc)
Bugger beat me to it!

Edited by selnic on Tuesday 19th May 19:34

myquest

78 posts

258 months

Tuesday 19th May 2009
quotequote all
Had the same problem the other weekend, only l/h fan working. Took right hand connector appart, cleaned up with emmery paper and working perfectly.

simonej

Original Poster:

5,513 posts

211 months

Tuesday 19th May 2009
quotequote all
I can't thank you guys enough!! smile

As I said before, I don't think the right hand fan has been working for a while.

Anyway, I cleaned and 'shinied up' all the electrical connections I could find'

Fuses (one was dark grey with crap for some reason)
Otter switch connections
Fan connections

However, I'm convinced it was the fan connections as they were full of crap and the right one was soaked! Anyway, what I'm going to do is order some new connectors, Maplin's?

Just to finish off and put my mind at rest this is what I found when I took it out for a 10 minute test drive;

5 minutes to get to 70 degrees. Then remained at 80 degrees from then on driving in suburban area at 30mph. Left it running on the driveway and the fans cut in at 83 after a minute or so. Then they went off at about 88. Then the temp rose to 90 and the fans came back on. I then turned it off and hoped all was good.

Does this sound right? Sorry to go on a bit but to be honest I'm just dead chuffed that I've managed to get it going and in a weird way I rather enjoyed it! biggrin

myquest

78 posts

258 months

Tuesday 19th May 2009
quotequote all
Sounds spot on to me, in heavy traffic this morning my temp was showing a steady 90 on the gauge which when checked with my multimeter equates to 85 or 86 so happy with that. Be prepared for temps to get slightly higher in higher ambient temps, logical really.....