Wont run with air flow meter plugged in?
Discussion
My chimaera starts fine and as it warms up starts running rough,once at normal temp it will hardly tick over and wont rev at all.
If i unplug the afm it suddenly recovers and runs ok,i understand this puts it into a basic get you home fuel map.
Having metered the afm it overshoots to 0.8 volts then slowly settles to 0.3/0.4 with the ignition on,idle values seem low,between 1.4 and 1.5.
Once warm the ignition on ,not running voltage is ranging from 0.02 to 0.3.
Im fairly sure the afm is at fault but would like reassurance before i buy a new one,also does anyone use one of the cheap ebay ones? wondered if they are any good.
Thanks for your help in advance.
If i unplug the afm it suddenly recovers and runs ok,i understand this puts it into a basic get you home fuel map.
Having metered the afm it overshoots to 0.8 volts then slowly settles to 0.3/0.4 with the ignition on,idle values seem low,between 1.4 and 1.5.
Once warm the ignition on ,not running voltage is ranging from 0.02 to 0.3.
Im fairly sure the afm is at fault but would like reassurance before i buy a new one,also does anyone use one of the cheap ebay ones? wondered if they are any good.
Thanks for your help in advance.
Mark Adams did this definative answer a while back:
Note that you can drive without an airflow meter in case of emergency (i.e. airflow meter disconnected), because the system will drop into a default (limp-home) mode based on throttle opening.
Most airflow meter faults will cause the engine to run excessively rich. However if the airflow meter remains connected whilst defective then the vehicle will probably not run. In most cases the output from a defective airflow meter will be in the range 2.0-2.5 Volts, which is a viable value. This represents a moderate load and will cause heavy over-fuelling without setting a fault code.
Testing is performed in the following manner. Peel back the rubber boot on the airflow meter connector and leave it plugged in to the airflow meter. Set up the digital multimeter to read voltage. Insert the negative probe into the Red/Black wire (sensor ground), and the positive into the Blue/Green wire (Airflow signal).
Turn on the ignition, but do not start the engine. The meter should immediately indicate a reading of approximately 0.3-0.34 Volts. Most defective airflow meters will overshoot to 0.8 Volts or higher, and take at least 2 seconds to come down to the correct voltage.
Now start the engine, and the reading should rise to 1.6 Volts (3.5 Litre engine) to 1.75 Volts (5.0 Litre engine).
The next test is full load, and as with the fuel pressure test it will require use of a rolling road or a steep hill in the same manner. Under full load the voltage should rise to 4.45 Volts (3.5 Litre engine) to 4.95 Volts (5.0 Litre engine).
On this injection system, the idle CO mixture adjuster is provided on the airflow meter. It is located in a boss on the top of the airflow meter, pointing towards the engine. Leaving the multimeter negative probe in the Red/Black wire, move the positive probe to the Blue/Red wire.
Now turn on the ignition but do not start the engine. Observe the voltage. The normal adjustment range is between 0.0 and 3.6 Volts, with the higher Voltages producing higher idle CO values. There are approximately 20 turns of the adjuster screw to cover the entire range.
Annoyingly, the adjustment may be clockwise or anticlockwise to increase the value, and this varies from meter to meter! For this reason it is always preferable to have the multimeter connected in this manner when adjusting idle CO, so that you see can something is actually happening.
Typical Voltages that would be found at this point are between 0.9 to 1.4 Volts for non-catalyst cars. This Voltage is always factory pre-set to 1.8 Volts for catalyst vehicles. A value near to 3.5 Volts will generally produce an idle CO value of 9-10%. These Voltages may be used as safe initial values particularly if no CO measuring equipment is available.
As for Ebay (read-Chinese) ones, there is some doubt about their voltage stability in the hot TVR engine bay, although nothing yet proven. Id stick to the Lucas ones. Ive seen recon' ones for about £125 or new ones for £160
Note that you can drive without an airflow meter in case of emergency (i.e. airflow meter disconnected), because the system will drop into a default (limp-home) mode based on throttle opening.
Most airflow meter faults will cause the engine to run excessively rich. However if the airflow meter remains connected whilst defective then the vehicle will probably not run. In most cases the output from a defective airflow meter will be in the range 2.0-2.5 Volts, which is a viable value. This represents a moderate load and will cause heavy over-fuelling without setting a fault code.
Testing is performed in the following manner. Peel back the rubber boot on the airflow meter connector and leave it plugged in to the airflow meter. Set up the digital multimeter to read voltage. Insert the negative probe into the Red/Black wire (sensor ground), and the positive into the Blue/Green wire (Airflow signal).
Turn on the ignition, but do not start the engine. The meter should immediately indicate a reading of approximately 0.3-0.34 Volts. Most defective airflow meters will overshoot to 0.8 Volts or higher, and take at least 2 seconds to come down to the correct voltage.
Now start the engine, and the reading should rise to 1.6 Volts (3.5 Litre engine) to 1.75 Volts (5.0 Litre engine).
The next test is full load, and as with the fuel pressure test it will require use of a rolling road or a steep hill in the same manner. Under full load the voltage should rise to 4.45 Volts (3.5 Litre engine) to 4.95 Volts (5.0 Litre engine).
On this injection system, the idle CO mixture adjuster is provided on the airflow meter. It is located in a boss on the top of the airflow meter, pointing towards the engine. Leaving the multimeter negative probe in the Red/Black wire, move the positive probe to the Blue/Red wire.
Now turn on the ignition but do not start the engine. Observe the voltage. The normal adjustment range is between 0.0 and 3.6 Volts, with the higher Voltages producing higher idle CO values. There are approximately 20 turns of the adjuster screw to cover the entire range.
Annoyingly, the adjustment may be clockwise or anticlockwise to increase the value, and this varies from meter to meter! For this reason it is always preferable to have the multimeter connected in this manner when adjusting idle CO, so that you see can something is actually happening.
Typical Voltages that would be found at this point are between 0.9 to 1.4 Volts for non-catalyst cars. This Voltage is always factory pre-set to 1.8 Volts for catalyst vehicles. A value near to 3.5 Volts will generally produce an idle CO value of 9-10%. These Voltages may be used as safe initial values particularly if no CO measuring equipment is available.
As for Ebay (read-Chinese) ones, there is some doubt about their voltage stability in the hot TVR engine bay, although nothing yet proven. Id stick to the Lucas ones. Ive seen recon' ones for about £125 or new ones for £160
Not actually used these guys but the prices seem fairish
http://www.probedistributors.co.uk/Products.aspx?M...
http://www.probedistributors.co.uk/Products.aspx?M...
Edited by blitzracing on Sunday 2nd August 18:47
Gassing Station | Chimaera | Top of Page | What's New | My Stuff