No spark at the plug
Discussion
Ok, I've got no hair left on my skull. Please help me sleep at night.
The Chim 500 is a non starter for more than three months now.
The magnetic pickup in the dizzy was faulty and has been replaced. The ground of the electronic module was faulty as well and has been fixed.
The plugs were diagnosed being at fault as well (tested on a bench) and replaced.
The leads are brand new.
Today, I've got a spark entering the dizzy but nothing at the plugs.
My mechanics tells me that he has checked the resistance of the leads and they are ok (no broken wires). He has also checked the dizzy finger and it seems alright.
When attempting to start the engine it wants to start, poughs and stops due to the weak spark.
Does anybody have a lead we can follow?
Thanks and regards
Philippe
The Chim 500 is a non starter for more than three months now.
The magnetic pickup in the dizzy was faulty and has been replaced. The ground of the electronic module was faulty as well and has been fixed.
The plugs were diagnosed being at fault as well (tested on a bench) and replaced.
The leads are brand new.
Today, I've got a spark entering the dizzy but nothing at the plugs.
My mechanics tells me that he has checked the resistance of the leads and they are ok (no broken wires). He has also checked the dizzy finger and it seems alright.
When attempting to start the engine it wants to start, poughs and stops due to the weak spark.
Does anybody have a lead we can follow?
Thanks and regards
Philippe
In addition to Simons comments above, id also check that the distributor is set up correctly so the rotor arm is pointing towards number 1 plug lead when number 1 cylinder is under compression near top dead center. If you look at the trigger lobes inside the distributor, they align with the pickup when the spark should occur, so you can check this corresponds to the static timing point of about 8 degrees BTDC. If the distrubutor has been removed at some point, the rotor arm / distributor can get out of out of phase, the gap can be to wide to get the spark to jump the gap from the rotor arm to the cap contact, or it will jump to the wrong lead. You may need to remove the distributor, rotate the arm to the correct position, then if the car is a pre serp, rotate the oil pump drive so it will re align with the new distributor position. Note that the rotor arm will move about 10' when you remove or replace the distributor as the gears mesh, so you need to take this into account if you align the rotor before you put the ditributor back in. It can be quite tricky getting it all to line up. If the distributor has never been removed, its still possible to rotate if far enough to get the rotor out of phase, so check the obvious.
Gassing Station | Chimaera | Top of Page | What's New | My Stuff




and original Gen Lucas one's can be hard to source now 