Fan problem continues, if I had hair I would pull it out!!!!
Discussion
Hi guys, thought I had fixed my fan problem by switching the relays. It was fine for a couple of days but tonight same old problem of them staying on returns, so that is another flat battery tomorrow :-(
I don't understand what it could be if it's not the relays. Pulling the connections off the otter switch doesn't have any effect, so it can't be the otter switch itself surely, or have I got that wrong?
The car has a new rad & new fans, is it possible there is a fault in the wiring somewhere, & if so where to start. I don't mind wielding spanners but electrickery is a complete mystery to me.
Any thoughts?
I don't understand what it could be if it's not the relays. Pulling the connections off the otter switch doesn't have any effect, so it can't be the otter switch itself surely, or have I got that wrong?
The car has a new rad & new fans, is it possible there is a fault in the wiring somewhere, & if so where to start. I don't mind wielding spanners but electrickery is a complete mystery to me.
Any thoughts?
I had this a while ago where the fans would randomly *start* when I turned off the ignition. This was more likely when the car had been sat for a while. If the fans had started, they would never turn off, unless I turned the ignition on and off. Then most of the time, the fans would stop (but not always).
The garages I took it to never diagnosed the fault and I ended up having the entire fan circuit rewired. It now works exactly as its supposed to - fans only on if hot and the ignition is on.
The garages I took it to never diagnosed the fault and I ended up having the entire fan circuit rewired. It now works exactly as its supposed to - fans only on if hot and the ignition is on.
Pull the relay & stick a test light across the opposite parallel terminals to see when the relay is getting the circuit from what should be (only) the otter switch. It will also isolate the fan circuit to ensure that your battery is still ok and that is the root cause. If there is nothing there you may be getting cross tracking on the inside of the fusebox due to water / corrosion / general abuse.. or even short circuits on the wires behind the fusebox.
spend said:
Pull the relay & stick a test light across the opposite parallel terminals to see when the relay is getting the circuit from what should be (only) the otter switch. It will also isolate the fan circuit to ensure that your battery is still ok and that is the root cause. If there is nothing there you may be getting cross tracking on the inside of the fusebox due to water / corrosion / general abuse.. or even short circuits on the wires behind the fusebox.
Thanks for that. The first bit went right over my head (stick a test light) ??, but I do get your drift. I have been thinking about this, & when I swapped the relays I left all the wiring & ECU on the floor in the foot well. As it was fine for a few days I put it all back & tidied the area up. That is when the problem reoccurred, so there must be a dodgy fuse or connection under there methinks.I am off the Dulfords next week for a couple of sender units, as a couple of the dials don't work, so I will ask them to trace & fix it while I am there.
Gassing Station | Chimaera | Top of Page | What's New | My Stuff


