I think I've finally located the pot on my hot/cold heater valve, which is currently constantly turning anti-clockwise.

Is it possible to test whether the pot is working or not to determine if I need a new pot or whether something else is the problem e.g. broken wire?

How would I go about testing it? Would I need to measure the resistance from the centre leg to the side legs to see if it changes as the motor turns?

Griffit

Original Poster:

375 posts

237 months

Thursday 13th September 2007
quotequote all
Anyone?

tumbleweed

JoolzB

3,549 posts

279 months

Thursday 13th September 2007
quotequote all
Yep you can test it if you have a multimetre. Check the resistance, think it should be something like 0 through to 10k ohms from memory. Somebody like David Beer will know for sure.

David Beer

3,982 posts

297 months

Friday 14th September 2007
quotequote all
Yep is 10k, check the wires to it, most likely one broken off.