There is a fire alarm in my new office.

I just want to check what I am being told by people with a vested interest!


I am told if it's there it must be working. Is this correct?

I am told it must be serviced at least every six months. Is this correct?


Many thanks.

surveyor

18,707 posts

215 months

Friday 14th March 2014
quotequote all
If it's there, not working and there's a fire, that costs a life you'd be looking at a breach of Health and Safety legislation.

If it's a leased office, then your lease will probably covenant to keep landlords fixtures and fitting in good and operating condition, replacing where necessary.

The servicing guidelines will be laid out by the manufacturer. 6 months does not seem daft for what could be a life saving warning device.

PurpleMoonlight

Original Poster:

22,362 posts

188 months

Friday 14th March 2014
quotequote all
Okay, ta.

firesafetydave

955 posts

279 months

Friday 14th March 2014
quotequote all
If you need it servicing, drop me a line. That is what my company specialize in
www.spectrumfireuk.com
David

Jer_1974

1,643 posts

224 months

Friday 14th March 2014
quotequote all
My fire alarm needs to be serviced every year and a documented fire drill done once a week.

Chrisgr31

14,298 posts

286 months

Saturday 15th March 2014
quotequote all
Jer_1974 said:
My fire alarm needs to be serviced every year and a documented fire drill done once a week.
Fire drill once a week? Alarm test surely? Drill (including full evacuation) at least once a year, but more frequently if large staff changes or in large buildings.

PurpleMoonlight

Original Poster:

22,362 posts

188 months

Saturday 15th March 2014
quotequote all
I have to agree.

Weekly tests and an annual service would seem adequate. Six monthly is a tad ott.

surveyor

18,707 posts

215 months

Saturday 15th March 2014
quotequote all
PurpleMoonlight said:
I have to agree.

Weekly tests and an annual service would seem adequate. Six monthly is a tad ott.
It depends entirely on the advice, and the use of the building.

If the manufacturer says 6 months, it's difficult to ignore. If your Risk Assessment shows a high chance of fire then even more so.

PurpleMoonlight

Original Poster:

22,362 posts

188 months

Saturday 15th March 2014
quotequote all
surveyor said:
It depends entirely on the advice, and the use of the building.

If the manufacturer says 6 months, it's difficult to ignore. If your Risk Assessment shows a high chance of fire then even more so.
What risk assessment would that be then? biggrin

Not high risk, no naked flames. Just office electrical.

surveyor

18,707 posts

215 months

Saturday 15th March 2014
quotequote all
PurpleMoonlight said:
surveyor said:
It depends entirely on the advice, and the use of the building.

If the manufacturer says 6 months, it's difficult to ignore. If your Risk Assessment shows a high chance of fire then even more so.
What risk assessment would that be then? biggrin

Not high risk, no naked flames. Just office electrical.
Don't start me..... who is telling you six months? Is it a recommendation or a requirement? If it's up to you and you don't feel necessary just document why... and hope you never have cause to need to defend the decision.

PurpleMoonlight

Original Poster:

22,362 posts

188 months

Saturday 15th March 2014
quotequote all
The people that would be servicing it say every six months.

I am a trust landlord of a few multi-occupied offices. They are all on fire alarm maintenance contracts, and they comprise an annual service of the alarm and checking of the extinguishers. I would think that if six monthly was a legal requirement they would be seeking to be undertaking it.

surveyor

18,707 posts

215 months

Saturday 15th March 2014
quotequote all
PurpleMoonlight said:
The people that would be servicing it say every six months.

I am a trust landlord of a few multi-occupied offices. They are all on fire alarm maintenance contracts, and they comprise an annual service of the alarm and checking of the extinguishers. I would think that if six monthly was a legal requirement they would be seeking to be undertaking it.
I think you have an answer. Just make sure there are no warranty/insurance requirements...

fridaypassion

11,458 posts

259 months

Saturday 15th March 2014
quotequote all
Waters are very muddy with Fire alarms. At some point your local fire station will have been and risk assessed it and whatever their recommendation is is what you do. I think somewhere there is some legislation that determines places of work with a certain amount of people must have a fire alarm or manual bell/klaxtons. It is surprisingly lax though the vast majority of "rules" surrounding fire alarms are just guidance. The industry in completely unregulated.

Obviously the better your fire alarm the better your position is if anything happens in terms of liability.

I work in the industry and theres little rhyme or reason. Some places we go to 4 times per year to service, some places of the same size we will visit only annually. Some are monitored others not.

If you want to see where you really stand for your particular situation get your local fire station out they will pinpoint for you exactly what is needed and then you have something meaningful to follow.

Loaded1me

189 posts

225 months

Saturday 15th March 2014
quotequote all
You need to carry out a fire risk assessment, which if you feel comfortable doing you can do yourself. However, once complete this becomes a document that will be referenced by the fire authority/HSE/Police/CPS should anything occur.If you haven't followed your assessment (whether conducted by yourself or others) and something acknowledged in the assessment lead to the fire, or injury/fatality then expect the book to be thrown at you. With reference to your alarm panel and overall system, you need to look to British Standard 5839 Pt 1. Below is a quick overview of what is expected, however, this can be adapted by a competent person (usually your alarm maintenance company) dependent on the use of your building.
For reference the fire authority won't carry out your risk assessment. Under the Regulatory Reform (Fire Safety) Order 2005, the responsibility for fire safety in buildings was removed from the fire authority and responsibility was placed on the landlord/end user as appropriate. They will however inspect, and they will expect to see a fire risk assessment.Without it they may prosecute you, or issue an improvement notice, as they now have such powers under the FSO 2005.

HTH.

BS5839 Pt1:

A commissioning certificate, log book and system diagram are required to be given to the system user upon the completion of an installation. After installation, every system should be regularly tested and serviced. BS5839, Part 1 recommends the following:

Daily (User) - Keep a daily record of faults and report them.

Weekly (User) - Activate a different call point or detector to check the system, log the details and report any faults.

Quarterly - Check the log book, operate a call point, simulate faults to check the control panel, visually check for any structural alterations, and log all details.

Annually - Carry out normal quarterly testing and also test every detector in situ and ensure all cable fittings are secure.

PurpleMoonlight

Original Poster:

22,362 posts

188 months

Sunday 23rd March 2014
quotequote all
The maintenance people came in this week to give the alarm system a service.

Apparently there are no sensors to the system, and it has to be manually activated if a fire is spotted!

There are two floors, both of which are internally open plan, so if both are occupied a fire would be spotted fairly quickly. But the design fault seems to be that one floor could be unoccupied so nobody would see a fire and activate the alarm.