Dr Mike Oxgreen

Original Poster:

4,470 posts

196 months

Sunday 3rd March 2019
quotequote all
We've had some work done on the house at Oxgreen Towers, and I told the workmen to lay some pre-made CAT 6 cables underneath the flooring. Unfortunately, one of those cables has got damaged at one end - somebody has managed to cut half-way through it.

The work is now complete, so lifting the flooring is not an option. The only option, it seems to me, is to cut off the damaged end of the cable and fit a plug myself. But I've never done it!

I've watched a couple of YouTube videos, and it seems doable. I don't own an RJ45 crimp tool, but I can buy one.

But I'm a bit confused about "A" and "B" wiring schemes. How do I know which scheme I should use when I fit a new plug to an existing pre-made cable? I suppose I could cut both the ends off the cable and put my own plugs on each end, and then I guess it only matters that I use the same scheme at each end. Is that right?

How easy is this? Do I need to find someone who's done it before and offer them some beer money, or is is something I can successfully learn to do myself?


Edited to add: Thanks to the mods for correcting my horrendous typo in the thread title!! beer

Edited by Dr Mike Oxgreen on Sunday 3rd March 15:40

Penelope Stopit

11,209 posts

140 months

Sunday 3rd March 2019
quotequote all
You don't need to use a crimp tool, I managed to do the job with a pair of pliers and it has lasted for several years

There are lots of diagrams on the Internet that show the pin-outs if you're not happy about copying what you have already got

Dr Mike Oxgreen

Original Poster:

4,470 posts

196 months

Sunday 3rd March 2019
quotequote all
Penelope Stopit said:
There are lots of diagrams on the Internet that show the pin-outs if you're not happy about copying what you have already got
But how do I know what I've already got? The plug on the end of the cable is opaque.

scjgreen

595 posts

165 months

Sunday 3rd March 2019
quotequote all
If you can check the termination colours at one end then just match them up at the other.

You'll want a Crimper if you are going to do a proper job though.

Teddy Lop

8,301 posts

98 months

Sunday 3rd March 2019
quotequote all
They're fiddly but not that difficult. Ideally a ~£10 tester will tell you if you've wired it right, or just use a coupler box for a crude but cheap repair - nothing worse than buying a tool you probably won't use again.

markiii

4,339 posts

225 months

Sunday 3rd March 2019
quotequote all
99% of the time it will be B wiring

Mr Pointy

13,434 posts

190 months

Sunday 3rd March 2019
quotequote all
Rather than piddle about buying crimp tools & the like look around for soneone who does AV installs - round here they advertise in the back of the local magazines, or ask on your local Facebook group. It isn't difficult but it is fiddly & you'll probably never use the tool again.

I'm tempted to ask how you managed to get installed cables with plugs on but I'll not bother. This scenario is why you should run cabling to jack points & use a patchcord to connect to the equipment.

ging84

9,548 posts

177 months

Sunday 3rd March 2019
quotequote all
Sounds like this is going to be an on going problem so you may as well get a crimp tool, you can get kits with a few connectors for less than £10

sleepezy

2,145 posts

265 months

Sunday 3rd March 2019
quotequote all
It's dead easy - I've connected the wiring in our house after the electrician left the wiring blank (as planned) at the 'distribution' end.

Ideally you need a crimp tool, tester (which will solve your A/B issue, but so will looking at the other end assuming you know where it is) and obviously some 'ends'. The tolls are only a few £ and the ends pennies so best to do a proper job in my view.

If you can get yourself to Leatherhead easily (and time is not an issue) then I can arrange for my 'kit' to get there for you to borrow - I'll even chuck in a few ends for you to use as I no longer have any need for the 100 odd I've left! But given the cost of the tools you'd be better off buying your own unless you literally live down the road as you'd spend more getting there than the cost of buying!

Dr Mike Oxgreen

Original Poster:

4,470 posts

196 months

Sunday 3rd March 2019
quotequote all
Thanks for the pointers so far!

Looking at the connector end-on I think it does look like B wiring.

I think I’m going to buy some connectors and a crimp tool off Amazon and have a go. Will report my success or abject failure!

Who me ?

7,455 posts

243 months

Monday 4th March 2019
quotequote all
Years ago ,on a Cat 5 job ( and remember this was cat 5, slow speeds) , we had a fault where builders had cut through a cat5 cable. As an emergency repair, we cut the cable and terminated/ jointed it on a cat 5 socket. Not exactly approved, but similar to terminating cable on a socket, at both ends and then patching through on a patch cable.

WinstonWolf

72,863 posts

270 months

Monday 4th March 2019
quotequote all
Dr Mike Oxgreen said:
Thanks for the pointers so far!

Looking at the connector end-on I think it does look like B wiring.

I think I’m going to buy some connectors and a crimp tool off Amazon and have a go. Will report my success or abject failure!
When you cut the damaged connector off you can use a multimeter to test continuity between each wire and the pin in the connector, that'll tell you for certain how it's wired.

anonymous-user

85 months

Monday 4th March 2019
quotequote all
I love the people that say its easy.

I always cock it up, even with proper tools. I struggle to get the cables to sit in the right places, it ge erally takes me at least 3 goes per end!

It could be because my eyes are old I suppose, I do struggle to see it clearly

anonymous-user

85 months

Monday 4th March 2019
quotequote all
Mr Pointy said:
I'm tempted to ask how you managed to get installed cables with plugs on but I'll not bother. This scenario is why you should run cabling to jack points & use a patchcord to connect to the equipment.
I am surprised at that too. TBH

VEX

5,259 posts

277 months

Sunday 10th March 2019
quotequote all
Quick and easy to do when you have the tools.

Where are you? Either I or my installer friends may be able to get to you to fix it.

V.

h0b0

9,100 posts

227 months

Monday 11th March 2019
quotequote all
keirik said:
I love the people that say its easy.

I always cock it up, even with proper tools. I struggle to get the cables to sit in the right places, it ge erally takes me at least 3 goes per end!

It could be because my eyes are old I suppose, I do struggle to see it clearly
The
OP has hands of a doctor though. Admittedly, that could mean surgeon or drunk.....or both.

I have terminated 2 cat 6 cables and they both tested OK first time. To be fair I spent my youth installing B&O systems and joining masterlink cables for fun. But, I still think with the right tools cat 6 is possible for most.

Durzel

13,027 posts

199 months

Monday 11th March 2019
quotequote all
I wouldn't crimp solid core CAT6. I've done it before and it worked, but it was unreliable and didn't perform very well. Better to punch it down into the terminating plate, or if you're trying to join two cables together use something like this - https://www.amazon.co.uk/dp/B003OSTGK0/ref=cm_sw_r...

If it's stranded cable you should be ok crimping though. If you've never done it before and you have a limited amount of cable to work with I'd suggest getting a pro in.

As said above CAT6 cable runs shouldn't have been terminated with plugs, they should have ended up unterminated in the wall voids, at wall plates (punched down) or a patch panel (again, punched)

Edited by Durzel on Monday 11th March 01:54

Dr Mike Oxgreen

Original Poster:

4,470 posts

196 months

Monday 11th March 2019
quotequote all
techiedave said:
Mr Pointy said:
I'm tempted to ask how you managed to get installed cables with plugs on but I'll not bother. This scenario is why you should run cabling to jack points & use a patchcord to connect to the equipment.
I am surprised at that too. TBH
I'm not sure I understand the question. This is a pre-made cable bought from Amazon, that I laid out along the route I wanted it to take, and told the guy laying the flooring to conceal it under the perimeter of the laminate. There's about a foot or two of spare cable that emerges from under the flooring in a corner of the room, where the switch lives. Unfortunately the cable has been damaged near the end and no longer works - fortunately though there will be enough length remaining once the bad bit is cut out.

Even if I had asked them to chase the cable into the wall and terminate with a wall socket, they could still have damaged the cable part way along and I'd be in a worse position.

Dr Mike Oxgreen

Original Poster:

4,470 posts

196 months

Monday 11th March 2019
quotequote all
Durzel said:
I wouldn't crimp solid core CAT6.
I don't know if the cable is solid core or stranded. How do you tell?

WinstonWolf

72,863 posts

270 months

Monday 11th March 2019
quotequote all
Dr Mike Oxgreen said:
Durzel said:
I wouldn't crimp solid core CAT6.
I don't know if the cable is solid core or stranded. How do you tell?
It's a pre-made cable, it *should* be stranded.