Cat 5 or 6
Author
Discussion

T5R+

Original Poster:

1,226 posts

240 months

Sunday 9th May 2010
quotequote all
Not really my forte but sure the PHers know this type of thing.

In the midst of rewiring my home (3 storey/many bedrooms) and wanted to put in a network to support networking/NAS/Streaming/etc. Decided to run 2 cables to each outlet.

Should I go with Cat 6 cable or stay with 5E. My thoughts were shielded, solid, FTP.....? Open to ridicule (!) or (ideally) advice.

confused

talkssense

1,441 posts

233 months

Sunday 9th May 2010
quotequote all
For the price difference betwee the 2 I'd go CAT 6, and run at least 4.

If you want to really future proof (as best you can) and cost isn't the main issue, then stick as much CAT 7 in as you can get away with

LocoBlade

7,653 posts

287 months

Sunday 9th May 2010
quotequote all
Definitely go CAT6 and as mentioned, go for more than 2 outlets if you can. The reason is not because you'll necessarily need that many network points for your LAN, but more because with the appropriate adapter / balun you can use CAT5/6 to transport so many other types of digital information around the house such as phone and various AV signals such as HDMI etc.

Driller

8,310 posts

309 months

Sunday 9th May 2010
quotequote all
talkssense said:
For the price difference betwee the 2 I'd go CAT 6, and run at least 4.
Do you mean at least 4 in total or at least 4 in each room?

Plotloss

67,280 posts

301 months

Sunday 9th May 2010
quotequote all
For residential applications, Cat5e is the way because Cat6 is a bd to work with given the available bend radius in the vast majority of homes..

Bend radius of 5e is roughly around the top of your thumb. Of Cat6 its around a side plate.

Added to which, if you're considering this for AV applications, most of the market is still centric around a non-packet switched environment so you're only looking at the cable as a set of conductors rather than as an cable optimised for packet bandwidth.

Beardy10

25,503 posts

206 months

Sunday 9th May 2010
quotequote all
Plotloss said:
For residential applications, Cat5e is the way because Cat6 is a bd to work with given the available bend radius in the vast majority of homes..

Bend radius of 5e is roughly around the top of your thumb. Of Cat6 its around a side plate.

Added to which, if you're considering this for AV applications, most of the market is still centric around a non-packet switched environment so you're only looking at the cable as a set of conductors rather than as an cable optimised for packet bandwidth.
This man sounds like he knows what he's talking about....having said that I haven't a clue what the last para means!

LocoBlade

7,653 posts

287 months

Sunday 9th May 2010
quotequote all
Cat6 doesn't necessarily require huge bend radius, you can get cable that accepts bends of 4x it's diameter the same as CAT5 recommendations. Its generally thicker cable so 4x its diameter means a slightly bigger radius, but nothing like the thumb / plate reference above.

Edited by LocoBlade on Sunday 9th May 22:18

Plotloss

67,280 posts

301 months

Sunday 9th May 2010
quotequote all
I can't see how that would be possible with the rigid stanchion that runs down the centre of the cable.

LocoBlade

7,653 posts

287 months

Sunday 9th May 2010
quotequote all
An example from a quick google...
http://www.netx-datacom.co.uk/data_sheets/data-she...
This one says 8x the radius when installing (ie when pulling the run), and 4x once it's installed and static.

I can't see why the stanchion would affect it that much, it's only a thin flexible plastic seperator up the middle. The types of radius you're talking about sound more like fibre optic type radius specs than copper.

Edited by LocoBlade on Sunday 9th May 22:29

PJ S

10,842 posts

258 months

Sunday 9th May 2010
quotequote all
Although it's tempting to go with the highest grade of cabling depending on price being a consideration, you'd be going way OTT with no tangible benefit, in all likelihood.
Cat 6 is only a requirement in areas where noise suppression is mandatory for the quality of signal to be maintained, rather than a nice to have unnecessary cost option.
And as Plotloss says, bending radius to keep the cable within transmission spec, makes for further reason not to use it if not strictly needed.

Plotloss

67,280 posts

301 months

Sunday 9th May 2010
quotequote all
I remain sceptical.

With Cat6 the frequencies involved are so high everything within the cable has an effect on the impedance of the cable and thus its ability to transmit data.

So if you were to bend a bit of Cat6 around a 20mm radius that would almost certainly deform the stanchion and permanently affect the bandwidth of the cable.

Cat6 isn't giving you much if anything given the restrictions on installation in residential all things considered and it's more expensive and harder to work with.

Yes it perhaps gives 10G expandability, if you change all your patch panels and outlets as well.

TwistingMyMelon

6,519 posts

236 months

Sunday 9th May 2010
quotequote all
Plotloss said:
For residential applications, Cat5e is the way because Cat6 is a bd to work with given the available bend radius in the vast majority of homes..

Bend radius of 5e is roughly around the top of your thumb. Of Cat6 its around a side plate.

Added to which, if you're considering this for AV applications, most of the market is still centric around a non-packet switched environment so you're only looking at the cable as a set of conductors rather than as an cable optimised for packet bandwidth.
Good post

LocoBlade

7,653 posts

287 months

Sunday 9th May 2010
quotequote all
Plotloss said:
I remain sceptical.
Here's another from a more reputable brand...
http://www.3m-net.de/quante/pdf/english/Cat_6_cabl...

This one's probably even tighter at 27mm, and 3M aren't a tinpot company that would make claims on a spec sheet unless it really was capable of it.

TBH though Cat5e is fine for the casual home user but I know if I was recabling mine now I'd go Cat6 just to future proof it. Who knows what we'll all be trying to stream over our home networks in 10 years time, even now HD streaming over a 100Mbit switch is marginal, so although Cat5e can go to gigabit over short lengths, who's to say in a few years time whether that will be sufficient?

Edited by LocoBlade on Sunday 9th May 22:51

Plotloss

67,280 posts

301 months

Sunday 9th May 2010
quotequote all
Can and do run 1080p through a packet switched 10-100 network today, with no loss and no problem.

Why bother shifting the data around when you can shift the output signal?

Granted there are data applications in which it may make sense but for residential even then I'd say it's over specced.


ymwoods

2,194 posts

208 months

Sunday 9th May 2010
quotequote all
Why not wire the backbone of the network using Cat6, IE between floors then router each floor and Cat 5 from there or is this a bit OTT for your needs?

sonic_2k_uk

4,008 posts

238 months

Monday 10th May 2010
quotequote all
Plotloss said:
For residential applications, Cat5e is the way because Cat6 is a bd to work with given the available bend radius in the vast majority of homes..

Bend radius of 5e is roughly around the top of your thumb. Of Cat6 its around a side plate.

Added to which, if you're considering this for AV applications, most of the market is still centric around a non-packet switched environment so you're only looking at the cable as a set of conductors rather than as an cable optimised for packet bandwidth.
Perfectly put yes

And i can whole heartedly agree with cat6 being a bd to work with.

Cat5e is rated to 1gbps, which for home use it well above anything which you will need for the foreseeable future. Even so, are you going to spend the £thousands required to buy the necessary switching and routing equipment needed to deal with higher speeds? And if you are, why not just got the whole hog and use fibre?

I stuck with cat5e smile

T5R+

Original Poster:

1,226 posts

240 months

Monday 10th May 2010
quotequote all
Okay so being "bending" toward 5.

This would be my choice.......

Cat 5E Shielded Cable FTP Solid Conductor 4 pair FTP Shielded.

yes or nono

Plotloss

67,280 posts

301 months

Monday 10th May 2010
quotequote all
Don't bother with FTP

Reduces the radius, adds cost (you need shielded patch panels, outlets and the like) and more often than not doesn't really bring anything useful to the table.

If the signal path runs past an AC unit, a couple of microwaves and some big fluro fittings then its possibly of use but generally, swerve it, more hassle than it's worth.

Matt..

4,035 posts

220 months

Monday 10th May 2010
quotequote all
I'm looking into this at the moment as well smile

I'd like a system that can take network/phones/tv/audio and is flexible enough for me to not have to run cables specifically for each of those. Cat 5 can do all except tv can't it? Is there a cable that can be used for TV? (TV just being normal rf signal).

Plotloss

67,280 posts

301 months

Monday 10th May 2010
quotequote all
You can put practically everything down Cat5e.

From infrared to 1080p video & HD sound.

Remarkable wire.