I have been suffering from a slow loss in pressure (1/2 bar over 2weeks) and last week total loss 6 times over a 2 day period in our system. I do not think there is a leak anywhere in the system (no staining or water coming up through the tiles) so had the boiler repair man come out to have a look as its under warranty. He mentioned that the boiler is fine but the slow / sudden loss could be due to not having an expansion vessel linked up to the underfloor heating. He thought that its possible that as its getting colder the sudden change in temp is causing an increase in pressure when the water gets to the manifold causing the boiler to dump water as a safety check.

Does this sound correct ? I thought I heard water rushing through the condensing pipework to the drain the other day but may be wrong...

andy43

13,343 posts

285 months

Tuesday 8th November 2011
quotequote all
What he probably means is your system has an expansion vessel sized to cope with a certain volume of water, but the additional ufh volume means you might need a bigger vessel or a secondary one adding to stop the overpressurising when everything gets warmed up.

caziques

2,849 posts

199 months

Wednesday 9th November 2011
quotequote all
With an underfloor system there has to be some sort of mechanism for expansion, without it the pressure will drop as the water is forced out each time it gets warm.

Are you saying that your system doesn't have some sort of expansion? If not you have a problem.

I fit an 8 litre vessel to all our systems, but a 4 litre one would probably suffice.

maddernj

Original Poster:

225 posts

277 months

Wednesday 9th November 2011
quotequote all
We only have what's in the combi boiler, having looked this morning overnight we have lost about 100ml of water through the condensing pipe......I am guessing this is what's accounting for the slow leak. the area we are heating is about 18m2

Gingerbread Man

9,173 posts

244 months

Wednesday 9th November 2011
quotequote all
All this talk of the condensate pipe. The condensate pipe, normally white 22mm overflow pipe coming out of the boiler, only found on a condensing boiler is there to route the condensate formed by the boiler to an outside (or inside) gulley/ stack pipe.

Do you mean the discharge pipe? This'll be copper and directed outside which is used for over expansion.


Expansion vessels can and do fail. They have a diaphragm (separating nitrogen and central heating water) in them which takes up the expanding water, these can split and fill the expansion vessel with water which removes the room for expansion.

If you can get to the expansion vessel, they have a schrader valve on them which when pressed should release air and not water. Also if you can access it, if it weights a tonne, it's probably 100% full of water. If you can't get to it which is quite common (combi especially!) if fitted at the back of the boiler, turn on the heating and watch the pressure gauge.

The pressure will rise as the water is heated, but if it goes from 1.5bar to 3bar, this is when the pressure relief valve will kick in and discharge the water to outside for safety. Could be a buggered expansion vessel, could be an expansion vessel that is too small.

Question is, did it used to work fine?

maddernj

Original Poster:

225 posts

277 months

Thursday 10th November 2011
quotequote all
[quote=Gingerbread Man]All this talk of the condensate pipe. The condensate pipe, normally white 22mm overflow pipe coming out of the boiler, only found on a condensing boiler is there to route the condensate formed by the boiler to an outside (or inside) gulley/ stack pipe.

Do you mean the discharge pipe? This'll be copper and directed outside which is used for over expansion.quote]

The only pipe I have routed out through the wall to a drain is the condensate pipe, I have a copper pipe also with a little hat on that sticks out ?

I could stick a bucket on that and see if anything is collected in their ??

The boiler and system is all brand new so I have nothing to compare against, I know the boiler is good as the chap from Remeha came out and gave it the all clear on Tuesday.

The boiler I have is a Remeha Avanta 39c, I live in a 3 bedhouse with 9 Rads and 18m2 of ufl.....do you think an extra expansion vessel is needed ? as it certainly seems like it at the moment.

andy43

13,343 posts

285 months

Thursday 10th November 2011
quotequote all
maddernj said:
I live in a 3 bedhouse with 9 Rads and 18m2 of ufl.....do you think an extra expansion vessel is needed ?
yes

RichyBoy

3,749 posts

248 months

Thursday 10th November 2011
quotequote all
No sign of any expansion vessel with my u/floor heating system, where would it usually be?

Gingerbread Man

9,173 posts

244 months

Thursday 10th November 2011
quotequote all
RichyBoy said:
No sign of any expansion vessel with my u/floor heating system, where would it usually be?
He's a combi, it'll be in the combi, but as the system is quite large, it would appear that he needs a larger expansion vessel than the combi comes equipped with. You can tee one off any where on the heating, normally as they come out of the boiler, common practice for when the built in one fails.

You need to be on site really and see it for yourself to diagnose.

RichyBoy

3,749 posts

248 months

Thursday 10th November 2011
quotequote all
Think I may have a pressure problem too. Not sure how to explain this. If I turn all the thermostats above the room temp so they all activate when I turn the boiler on, 2 of the 4 red things that pull down take a couple of minutes longer to pull down. It's not really a problem but if it gets worse when it's colder it may be. If it's cold I only put the underfloor heating on for an hour a day and the rooms seems to stay at 23 degrees celsius plus till I go to sleep.

maddernj

Original Poster:

225 posts

277 months

Wednesday 23rd November 2011
quotequote all
12l vessel to be fitted in a couple of weeks...£160 all in

Cogcog

11,838 posts

266 months

Thursday 24th November 2011
quotequote all
bloke next dor with GShp & UFH had a manifold leak abd his expansion vessel kept collapsing