Building Regs - Window Bars in Flat, Separating Ceiling
Author
Discussion

skwdenyer

Original Poster:

18,707 posts

271 months

Sunday 20th November 2011
quotequote all
I wonder if anyone can help with a couple of issues?

I'm renovating a shop + flat above at the moment. There's no material change of use (flat above was a flat, shop was a shop). On a first 'once over' the BCO has come up with the following which are in addition to the new works being done (new kitchen, new bathroom, rewiring, etc. in the flat):

Windows - Protection from Falling

I've replaced the sash windows at the front of the flat with new sash windows. The openings, etc. are as original. The BCO has asked for bars to be installed to prevent falling. Is he entitled to do this?

Separating Ceiling

The old shop ceiling was simply lath + plaster over the floor joists of the flat above. That's been removed - it was in bad way. I was proposing to renew it with soundblock + fireline to a suitable spec, etc. The BCO is asking for it to be specced as per a new conversion, i.e. the 'full works' including a sound test.

Again, there's no material change of use, and this is just a straight refurbishment. Is this a reasonable requirement? I'm on a rather tight fit-out / build schedule, and am keen not to get too derailed. Also (given it is a 150 year old building) I'm a bit concerned that other parts of the structure may negate whatever I do at ceiling level and result in a 'fail' on the sound tests.

Sam_68

9,939 posts

276 months

Sunday 20th November 2011
quotequote all
Refer him to Regulation 3 of the Building Regulations.

Bottom line as I understand it: Approved Document K (protection from falling) and Approved Document E (resistance to passage of sound) are not 'relevant requirements' for the purposes of 'material alterations', so if you're merely replacing existing (as opposed to creating new work), there is no obligation to meet current standards.

With respect to the window guardings, however, you may wish to consider your liability and obligations under H&S legislation in your role as the 'designer' to undertake a Designer's Risk Assessment for the proposed work, particularly now that the BCO has drawn your attention to the hazard.

Steffan

10,362 posts

259 months

Sunday 20th November 2011
quotequote all
Sam_68 said:
Refer him to Regulation 3 of the Building Regulations.

Bottom line as I understand it: Approved Document K (protection from falling) and Approved Document E (resistance to passage of sound) are not 'relevant requirements' for the purposes of 'material alterations', so if you're merely replacing existing (as opposed to creating new work), there is no obligation to meet current standards.

With respect to the window guardings, however, you may wish to consider your liability and obligations under H&S legislation in your role as the 'designer' to undertake a Designer's Risk Assessment for the proposed work, particularly now that the BCO has drawn your attention to the hazard.
Sam is spot on.

I would definitely fit guards because this could very easily save a life.

Why would you not fit them.

Are you fitting smoker detectors? Just think about it.

torqueofthedevil

2,088 posts

208 months

Sunday 20th November 2011
quotequote all
Why would he need to fit Bars? Do u have bars on your windows?!?!?

Steffan

10,362 posts

259 months

Sunday 20th November 2011
quotequote all
torqueofthedevil said:
Why would he need to fit Bars? Do u have bars on your windows?!?!?
Ground floor property.

In the flats I rent out I always fit bars on upper floor flats.

Up to you. I would fit them

torqueofthedevil

2,088 posts

208 months

Sunday 20th November 2011
quotequote all
That seems bizarre. Never seen it. Would never do it. Wouldn't rent a house with bars on the windows.

chris1roll

2,069 posts

275 months

Sunday 20th November 2011
quotequote all
torqueofthedevil said:
That seems bizarre. Never seen it. Would never do it. Wouldn't rent a house with bars on the windows.
Agreed. IMHO its more likely to cost a life.
In my 30 years I have managed to never fall out of a window. I have, however been woken at 2am with the smoke alarm going mental and chaos ensuing.
Doors are only ever on the thumb latch, and there are no locks on the windows, let alone bars!
The house we're tenants in now, had blocks screwed into the sashes to stop them being opened more than about 2 inches. they came out the second day we were there.

mk1fan

10,919 posts

256 months

Sunday 20th November 2011
quotequote all
They maybe applying the same requirement to comply with current thermal & ventilation standards that they apply when replacing ceilings below roofs. It is a recent change to their 'powers'.

I assume that the window sills are low. If they are the the replacement windows should have had safety glass and have strengthening in the frame - assuming you have used uPVC.

That said a sound test for what is essentially a repair replacement is a touch overkill. A touch of common sense would suggest that what you propose is a vast improvement. Given the construction (you mention lath & plaster) you may find the remaining structure is transmitting enough sound for it to fail.

Slagathore

6,225 posts

223 months

Sunday 20th November 2011
quotequote all
I thought the regs for new windows were that they had to open a certain amount to allow you to escape in the event of a fire.

Surely, fitting bars would prevent that?

jules_s

5,302 posts

264 months

Sunday 20th November 2011
quotequote all
Slagathore said:
I thought the regs for new windows were that they had to open a certain amount to allow you to escape in the event of a fire.

Surely, fitting bars would prevent that?
It's all about restraints at certain heights. I've argued in the past (successfully) that glazing transoms can provide the protection needed.

I seem to recall acoustic enhancement between floors on refurbishments has been mandatory for a while now?

dudleybloke

20,553 posts

217 months

Sunday 20th November 2011
quotequote all
iv got them on my windows.

its a single 50mm o/d bar running horizontaly across the window approx 1meter above the floor height.


(yes i know i need to clean the glass!)

as far as im aware they are a legal requirement.

having lived with them for a few years they are a good idea and you soon get used to them.

skwdenyer

Original Poster:

18,707 posts

271 months

Sunday 20th November 2011
quotequote all
Steffan said:
Sam_68 said:
Refer him to Regulation 3 of the Building Regulations.

Bottom line as I understand it: Approved Document K (protection from falling) and Approved Document E (resistance to passage of sound) are not 'relevant requirements' for the purposes of 'material alterations', so if you're merely replacing existing (as opposed to creating new work), there is no obligation to meet current standards.

With respect to the window guardings, however, you may wish to consider your liability and obligations under H&S legislation in your role as the 'designer' to undertake a Designer's Risk Assessment for the proposed work, particularly now that the BCO has drawn your attention to the hazard.
Sam is spot on.

I would definitely fit guards because this could very easily save a life.

Why would you not fit them.

Are you fitting smoker detectors? Just think about it.
Thank you. Yes, I'm fitting smoke detectors (well, have fitted them). The problem with bars is that (a) they may expose a world of pain in the fittings (poor quality brick, plastic windows so no firm fixings into the frame, and so on) which, amongst other things, could open up different avenues of liability. But more importantly, I don't think it is terribly good to allow a BCO (or anbybody else in authority) to present something as 'mandatory' when in fact it is not. I'm absolutely open to a suggestion of window bars (or something else), but if I can't rely upon the BCO's word as to the law on this point then what else do I have to worry about being overriden when I've designed it to be thoroughly compliant.

Re the the ceiling, the issue of 'materiality' seems to have been the question, and thanks for pointing-out such an (apparently) unambiguous source to back up the suggestion. I've read and re-read Part E, which continually talks about works which I'm not doing, but I'd missed the blindingly obvious higher-level policy.

Now to ask the BCO gently if he's sure I'm withing Part E on account of Regulation 3... smile

skwdenyer

Original Poster:

18,707 posts

271 months

Monday 21st November 2011
quotequote all
jules_s said:
It's all about restraints at certain heights. I've argued in the past (successfully) that glazing transoms can provide the protection needed.
In this case, the windows are sashes. The cills are at around 700mm above FFL. The usual reg is a minimum of 800mm above FFL. No transom bars here. The BCO was concerned about the situation with the window open, not with it closed.

jules_s said:
I seem to recall acoustic enhancement between floors on refurbishments has been mandatory for a while now?
I can't find reference to that anywhere, but would be grateful for guidance. There is reference to thermal performance, as in this found online:

Forest of Dean BCO said:
Q When is it necessary to make a Building Regulations application?

An owner or occupier of a building is required by law to make a Building Regulations application to carry out the following works: -

...

Work required by Regulation 4A, the renovation of a thermal element. Which is the installation of a new or replacement layer to or into a surface of a building element, such as re-rendering or plastering an outside wall or re roofing and introducing say roof felt to a tiled roof that was previously unfelted. The regulations require that where it is technically and economically feasible that insulation be introduced into such works.

Work required by Regulations 4B, where there is a change to the buildings energy status. Such as the installation of a radiator or heating appliance in an unheated room such as an unheated flat lobby/hallway or integral/attached domestic garage.
In my case, I was proposing to dramatically upgrade the thermal (and fire) performance of the ceiling, and to implement something pretty effective from a sound PoV, but not wanting the time, cost, or risk of a test.

Can anybody shed any more light on this? Thanks!

Sam_68

9,939 posts

276 months

Tuesday 22nd November 2011
quotequote all
skwdenyer said:
Forest of Dean BCO said:
Q When is it necessary to make a Building Regulations application?

An owner or occupier of a building is required by law to make a Building Regulations application to carry out the following works: -

...

Work required by Regulation 4A, the renovation of a thermal element. Which is the installation of a new or replacement layer to or into a surface of a building element, such as re-rendering or plastering an outside wall or re roofing and introducing say roof felt to a tiled roof that was previously unfelted. The regulations require that where it is technically and economically feasible that insulation be introduced into such works.

Work required by Regulations 4B, where there is a change to the buildings energy status. Such as the installation of a radiator or heating appliance in an unheated room such as an unheated flat lobby/hallway or integral/attached domestic garage.
In my case, I was proposing to dramatically upgrade the thermal (and fire) performance of the ceiling, and to implement something pretty effective from a sound PoV, but not wanting the time, cost, or risk of a test.

Can anybody shed any more light on this? Thanks!
If you click on the link I gave above, then click the 'next provision' button it will take you to Regulation 4.

skwdenyer

Original Poster:

18,707 posts

271 months

Tuesday 22nd November 2011
quotequote all
Sam_68 said:
skwdenyer said:
Forest of Dean BCO said:
Q When is it necessary to make a Building Regulations application?

An owner or occupier of a building is required by law to make a Building Regulations application to carry out the following works: -

...

Work required by Regulation 4A, the renovation of a thermal element. Which is the installation of a new or replacement layer to or into a surface of a building element, such as re-rendering or plastering an outside wall or re roofing and introducing say roof felt to a tiled roof that was previously unfelted. The regulations require that where it is technically and economically feasible that insulation be introduced into such works.

Work required by Regulations 4B, where there is a change to the buildings energy status. Such as the installation of a radiator or heating appliance in an unheated room such as an unheated flat lobby/hallway or integral/attached domestic garage.
In my case, I was proposing to dramatically upgrade the thermal (and fire) performance of the ceiling, and to implement something pretty effective from a sound PoV, but not wanting the time, cost, or risk of a test.

Can anybody shed any more light on this? Thanks!
If you click on the link I gave above, then click the 'next provision' button it will take you to Regulation 4.
smile Sorry, I wasn't clear. I understood what Regulation 4 was about. What I meant was that I had only seen a requirement to comply with Regulation 4 when refurbishing a ceiling, etc., not an additional requirement to comply with Part E. It is this additional burden which I can't seem to find codified, but which the BCO appears to want me to comply with nonetheless.

Sam_68

9,939 posts

276 months

Tuesday 22nd November 2011
quotequote all
skwdenyer said:
...additional requirement to comply with Part E. It is this additional burden which I can't seem to find codified, but which the BCO appears to want me to comply with nonetheless.
He appears to be relying on Paragraph 2 of Section 3 which says (in plain English) that for most of the Building Regulations (ie. excluding parts A, B, M and thermal/energy use elements as subsequently defined) your only obligation is not to make the situation any worse than it was before.

In other words, you don't have to comply with current regs, but you're not allowed do work that makes a previously compliant element non-compliant, and you're not allowed to make a previously non-compliant element even worse.

The problem you have is in proving that the work you have done will not have worsened the sound transmission through the floor. If he's being an anally retentive jobsworth about it, the only way of doing this - given that, as you freely admit, there has been a change in specification from lath-and-plaster to soundblock and fireline - would be to sound test before and after. If you had sound tested the floor in its original (lath and plaster) form, your only requirement would have been that the sound resistance should not be any worse than it was, but since you don't have that test result as a reference (and again, if he's being an ahole about it), your only option will be to prove that you are compliant with the current standard.

He's being a tt, since anyone with an ounce of common sense and technical knowledge will recognise that there would have been no detriment from the change of spec., but other than appealing to his sense of reason (or failing that, his senior manager...), you may struggle to win your argument.

Perhaps try negotiating on the basis of agreeing the minimum specification that he acknowledges (on the basis of common sense and experience) would definitely exceed the performance of the previous lath-and-plaster?

Or play the silly buggers game with him and simply reinstate lath and plaster, so that you can argue that there has been no change in specification?


Edited by Sam_68 on Tuesday 22 November 21:02