quotequote all
Morning all

As some will know I have had previous problems with my Oil fired combi boiler.

Had it serviced a month ago - having sold we are moving out in 4 weeks so got it serviced and filled Oil tank up for new owners. The last three nights we have woken up the following morning to the burner lockout light on. Once pressed the boiler is fine all day/evening - at some point during the night this burner lockout come on and boiler shuts down. My wife heard it conk out at around 1am this morning. The heating was turned off last night to check if it still done it when the heating timer was switched off - it did still do it.

We thought it may be something as simple as a dirty photocell - but why would it cause the burner lockout to come on at roughly same time every night? we thought if it was a dirty photocell it would shut down far more often throughout the day?? Could it something electrical perhaps?

We have a guy coming round in a couple of hours - not an oil heating engineer - the guy whose firm serviced the thing - their oil guy has left, so this guy is just coming round to have a look.

Anyone have any ideas ? My wife will be home and will be checking if there are any responses. Thanks in advance for any help.


PoshTwit

1,218 posts

184 months

Monday 21st November 2011
quotequote all
We had problems with our external Worcester Heatslave all through the really cold snap early in the year (with an 18-month old - not fun!).

Company that serviced it came out 3-times to no avail and could not make it fault whilst they were there.

One of my guys (I run a Commercial HVAC Maintenance Co.) came out and recommended we change the service parts (Nozzle, electrodes, etc) again to be safe but also could not get it to fault.

In the end, I stripped the burner down and proved I had spark, etc at ignition but no fuel... Had fuel before pump... Turns-out internal gauze filter in the pump had got blocked with some crud which was dislodged once it was running freely, but on start-up (usually 0530 each morning) would block the route and starve fuel causing the bruner to lock out.

Thinking that this was an obvious thing which had been missed I called and spoke to the company that did the service (who never charged me co-incidentally - bless them)to be told "We wouldn't have looked at that anyway"

Might be worth a try as your symptoms appear similar to mine!

HTH

Craphouserat

Original Poster:

1,542 posts

232 months

Monday 21st November 2011
quotequote all
PoshTwit said:
We had problems with our external Worcester Heatslave all through the really cold snap early in the year (with an 18-month old - not fun!).

Company that serviced it came out 3-times to no avail and could not make it fault whilst they were there.

One of my guys (I run a Commercial HVAC Maintenance Co.) came out and recommended we change the service parts (Nozzle, electrodes, etc) again to be safe but also could not get it to fault.

In the end, I stripped the burner down and proved I had spark, etc at ignition but no fuel... Had fuel before pump... Turns-out internal gauze filter in the pump had got blocked with some crud which was dislodged once it was running freely, but on start-up (usually 0530 each morning) would block the route and starve fuel causing the bruner to lock out.

Thinking that this was an obvious thing which had been missed I called and spoke to the company that did the service (who never charged me co-incidentally - bless them)to be told "We wouldn't have looked at that anyway"

Might be worth a try as your symptoms appear similar to mine!

HTH
Thanks for the reply - guy came out and cleaned photocell - I wasn't home o/h dealt with him. His oil guy has left so he's not 100% with oil boilers - we will know tomorrow morning if what he has done has worked - if not he'll be back out. I will keep this reply in mind if he comes back out. I'm sick of this boiler and pretty sick of oil boilers....moving out to a new place with gas.....god bless gas !

Thanks again !

Henry-F

4,791 posts

276 months

Tuesday 22nd November 2011
quotequote all
You need to make sure any pre-filters between the tank and boiler are clear as well. There will usually be one by the isolator valve on your oil tank and possibly one in line on the oil line it's self.

It could be that the oil gets a bit thicker at night as temperatures drop.

The filter within the oil tank valve usually gets ignored an can totally block with all the crud from the tank.

Henry smile

eddie1980

419 posts

219 months

Tuesday 22nd November 2011
quotequote all
The filter on my oil tank isolator was not changed for 2 years due to the valve ceasing. I have fitted a new one recently in prep for winter along with a new filter. On striping the old one to inspect the filter was heavly coated and I would think looking at it would not have made it though this winter. Thats on a 10 year old plastic tank and about 3000L of oil drawn though the filter.

They do need changing.

Craphouserat

Original Poster:

1,542 posts

232 months

Tuesday 22nd November 2011
quotequote all
Thanks for the extra info - since hes been round and cleaned photocell it has not happened again - touch wood - if it does I will mention these extra pieces of info.

Cheers

Kudos

2,674 posts

205 months

Tuesday 22nd November 2011
quotequote all
Craphouserat said:
Morning all

having sold we are moving out in 4 weeks so got it serviced and filled Oil tank up for new owners.
Very generous given the price!

Milky Joe

3,851 posts

235 months

Tuesday 22nd November 2011
quotequote all
Hijacking the thread somewhat does anyone have any idea of the cost of oil heating compared with gas following the recent 20% price rises.

New house has oil central heating and trying to work out if the expense of converting to gas is worth it.

Craphouserat

Original Poster:

1,542 posts

232 months

Wednesday 23rd November 2011
quotequote all
Milky Joe said:
Hijacking the thread somewhat does anyone have any idea of the cost of oil heating compared with gas following the recent 20% price rises.

New house has oil central heating and trying to work out if the expense of converting to gas is worth it.
We pay around £100 a month to oil supply company - wife pays it - I think it just go's straight into an acccount - when we need oil we phone up and top it up. They set a minimum of 500 litres - I think. We top up twice a year and have never run out. We top up near end of autumn - so unlike some neighbours we never run out during a bad winter when delivery lorry can't make it down/up the hill. We've never needed to top up our account and I believe we also manage a yearly service out of what we pay monthly. As I said wife pays this but I'm pretty sure what I've said is accurate.

HTH

Kudos

2,674 posts

205 months

Wednesday 23rd November 2011
quotequote all
Milky Joe said:
Hijacking the thread somewhat does anyone have any idea of the cost of oil heating compared with gas following the recent 20% price rises.

New house has oil central heating and trying to work out if the expense of converting to gas is worth it.
Very similar, if not cheaper than gas

MrCheese

363 posts

214 months

Wednesday 23rd November 2011
quotequote all
Milky Joe said:
Hijacking the thread somewhat does anyone have any idea of the cost of oil heating compared with gas following the recent 20% price rises.

New house has oil central heating and trying to work out if the expense of converting to gas is worth it.
At the end of the day it isn't that much more than gas, provided the house is insulated etc.

crankedup

25,764 posts

274 months

Wednesday 23rd November 2011
quotequote all
For some years I was paying for an oil boiler service, once each year the company would arrive and set to with the job. Couple of years back I decided to see exactly what was being done for the 65 quid I paid. The answer is 'not very much', jeeeeez I now service my own boiler. Take off the front boiler case inspection hatch, remove baffle plate and give a good clean out with small brush and vacuum. Replace components. Replace jet. Total time about 40 minutes.
O.K. its not a huge amount of money saved but it feels better in my pocket than that cash leaving my pocket.

Arthur Jackson

2,111 posts

261 months

Wednesday 23rd November 2011
quotequote all
crankedup said:
For some years I was paying for an oil boiler service, once each year the company would arrive and set to with the job. Couple of years back I decided to see exactly what was being done for the 65 quid I paid. The answer is 'not very much', jeeeeez I now service my own boiler. Take off the front boiler case inspection hatch, remove baffle plate and give a good clean out with small brush and vacuum. Replace components. Replace jet. Total time about 40 minutes.
O.K. its not a huge amount of money saved but it feels better in my pocket than that cash leaving my pocket.
ALWAYS replace the nozzle (£5?) and ALWAYS set the mixture correctly. Too rich is messy, too lean WILL melt the baffles.

Milky Joe

3,851 posts

235 months

Wednesday 23rd November 2011
quotequote all
thumbup Thanks for the replies, as you were OP. smile

Milky Joe

3,851 posts

235 months

Tuesday 13th December 2011
quotequote all
Another question for you oilers, what are you paying for a boiler service & do you notice any difference?