Anybody know anything about the marking system for glass?

I have 3 large (6 feet x 6 feet) floor level windows on my new house, each divided into quite large panels (most approx 4 feet x 2 feet) but only some paines are kitemarked.

I would have though they should all be marked?

J114rvy

181 posts

182 months

Tuesday 22nd November 2011
quotequote all
Could be behind the gasket or beading

Z4monster

1,442 posts

291 months

Tuesday 22nd November 2011
quotequote all
They can be edge marked and not visible when fitted - Daft idea to me, I'd want to be able to check it.

Are the marked ones all the same? I could be that there was one damaged and replaced and the marking system is different on that one. If it's UPVC then it's probably hidden behind the beading but that can be a dickens of a thing to get off/on again without marking it (unless you're practiced at it.)

Also any below 800mm from floor level must be kire marked as they should be toughened or laminated glass. Those above that level do not neccesarily need to be done so might not be safety glass


Edited by Z4monster on Tuesday 22 November 21:27

Cogcog

Original Poster:

11,838 posts

266 months

Wednesday 23rd November 2011
quotequote all
they are wood and the beading isn't big enoughh to hide it. i wonder if they just do one paine per window?

Skyedriver

23,769 posts

313 months

Wednesday 23rd November 2011
quotequote all
I was told that whilst toughened glass is kitemarked laminated isn't so if the glazier has used laminated in areas such as the doors and below 800mm (check the regs) then that could be the reason.
Awaiting being told that what I was told was rubbish........

V8 Animal

6,015 posts

241 months

Wednesday 23rd November 2011
quotequote all
Skyedriver said:
I was told that whilst toughened glass is kitemarked laminated isn't so if the glazier has used laminated in areas such as the doors and below 800mm (check the regs) then that could be the reason.
Awaiting being told that what I was told was rubbish........
Incorrect Partialy

Toughened and Laminated are both safety glass and should be marked T or L with a EN number

Fitting of safety glass in low level glazing is mandatory since 1982 however marking of it wasn't.

If you knock on the glass you will get a deeper noise if laminated is fitted.

HTH

Cogcog

Original Poster:

11,838 posts

266 months

Thursday 24th November 2011
quotequote all
V8 Animal said:
Incorrect Partialy

Toughened and Laminated are both safety glass and should be marked T or L with a EN number

Fitting of safety glass in low level glazing is mandatory since 1982 however marking of it wasn't.

If you knock on the glass you will get a deeper noise if laminated is fitted.

HTH
so all paines below 800mm should have the kite mark?


dickymint

29,266 posts

289 months

Thursday 24th November 2011
quotequote all
Cogcog said:
V8 Animal said:
Incorrect Partialy

Toughened and Laminated are both safety glass and should be marked T or L with a EN number

Fitting of safety glass in low level glazing is mandatory since 1982 however marking of it wasn't.

If you knock on the glass you will get a deeper noise if laminated is fitted.

HTH
so all paines below 800mm should have the kite mark?
Should conform to BS6206 and be marked with the letters L (laminated) or T (toughened) along with the manufacturers registration number. Not necessarily a Kite Mark.


Cogcog

Original Poster:

11,838 posts

266 months

Thursday 24th November 2011
quotequote all
dickymint said:
Should conform to BS6206 and be marked with the letters L (laminated) or T (toughened) along with the manufacturers registration number. Not necessarily a Kite Mark.
i will look