Is my Boiler on the way out?!?
Is my Boiler on the way out?!?
Author
Discussion

Gazzas86

Original Poster:

1,804 posts

202 months

Wednesday 23rd November 2011
quotequote all
Evening Folks,

Have only been in the new pad for 3 weeks, and so far I’ve had to re-light the boiler 3 times,

It's a Worcester-Bosch 240, Hot water on Demand type, I've googled it, and I believe it was discontinued a few years back,

Its only happened when in the shower, Shower on, water goes hot as you would expect, then after approx 5 mins of being in the shower, it suddenly goes cold, Go to the airing cupboard, check to see for a flame, and its out. Takes about 10 ignites to get the flame back, and all hunky dory again, This is my first house, so I’m not really clued with boilers,

Anyone got any advice??

Cheers

Gaz

jimbo65

752 posts

229 months

Wednesday 23rd November 2011
quotequote all
Yes,it is same happened with my bosch, started with the swith over valve from heating to
hot water,had that repaired, then happened again and again, then it was limescale, that was not
covered on the insurance, then replacement boiler.

£2760 later perfect.

Big_Dog

997 posts

216 months

Wednesday 23rd November 2011
quotequote all
Give Worcester a call in the morning. I found them really helpful with mine, they get pretty busy after about 9:30 when the engineers start calling in.

craigjm

21,787 posts

231 months

Wednesday 23rd November 2011
quotequote all
When was it last serviced? Sounds to me like it might need a flush especially if you are in a hard water area. What you are describing usually happens when the boiler overheats and the safety cutoff kicks in. I had it happen a few years ago on a Valliant. Flushed it and it was fine

Gazzas86

Original Poster:

1,804 posts

202 months

Wednesday 23rd November 2011
quotequote all
Ouch!!,

I know my enery supplier do boiler cover for a couple of quid a month, is it worth signing up for it now incase the inevitable happens and i need a new boiler frown, not what i really need, since i've got to kit the place out with furnature..appliances etc

Gazzas86

Original Poster:

1,804 posts

202 months

Wednesday 23rd November 2011
quotequote all
craigjm said:
When was it last serviced? Sounds to me like it might need a flush especially if you are in a hard water area. What you are describing usually happens when the boiler overheats and the safety cutoff kicks in. I had it happen a few years ago on a Valliant. Flushed it and it was fine
The previous occupants said it was serviced in 2007, how often do they need servicing??

BIGMIKE1

339 posts

259 months

Wednesday 23rd November 2011
quotequote all
Should be serviced every year, but a service wont help it. Sounds like its overheating and tripping pilot light. Could be not modulating gas pressure and staying on high. Possible faulty HW thermistor, faulty gas valve, blocked calorifier, blocked diverter, the pipe between the pump and diverter also gets partially blocked on 240s causing overheats. Worcester probably wont be much use as manufacturers don't generally get involved in old boilers. All be careful signing up for a contract with your energy supplier,etc as most dont cover blockages, which it quite possibly is.
It will be fixable and could be very simple if just HW thermistor for instance but could also get expensive, not new boiler cost though unless your thinking of upgrading anyway.

Gazzas86

Original Poster:

1,804 posts

202 months

Wednesday 23rd November 2011
quotequote all
BIGMIKE1 said:
Should be serviced every year, but a service wont help it. Sounds like its overheating and tripping pilot light. Could be not modulating gas pressure and staying on high. Possible faulty HW thermistor, faulty gas valve, blocked calorifier, blocked diverter, the pipe between the pump and diverter also gets partially blocked on 240s causing overheats. Worcester probably wont be much use as manufacturers don't generally get involved in old boilers. All be careful signing up for a contract with your energy supplier,etc as most dont cover blockages, which it quite possibly is.
It will be fixable and could be very simple if just HW thermistor for instance but could also get expensive, not new boiler cost though unless your thinking of upgrading anyway.
Cheers Mike, so basically it could be anything hehe, On the boiler itself, theres a sticker which is a local buisness, i may try giving them a ring, i assume their the ones who carried out the service, i also assume you're very 'switched on' in this field on what you're telling me, Appologies for being Nieve however is this a job for any boiler engineer??, or is it a specialist thing???, i don't want some guy coming out telling me its this, then this, then this, Then taking my pants down and shafting me for a new boiler

Thanks

Gazzas86

Original Poster:

1,804 posts

202 months

Wednesday 23rd November 2011
quotequote all
After your post mike, i popped upstairs to have a look at the boiler, i took a photo so you can see it's fairly old, You mentioned it was probably overheating and tripping etc, would this be caused by the rotary temp switch on the boiler being set too high???? see below,


It's been set fully Clock-Wise since we've moved in, just out of curiosity i've turned it down no. 4/5 and will see if it makes a difference.
In you're opinion do you think it will?

Regards

Gaz

BIGMIKE1

339 posts

259 months

Wednesday 23rd November 2011
quotequote all
On your picture Gaz the pressure gauge is on zero, this wont be helping with overheating, under the boiler there should be a flexible braided pipe with either one or two valves on it. Turn the boiler off and open the taps until the needle reaches 1bar on the gauge, might be worth checking there's no air in your upstairs radiators after you get it to 1bar. if you get any air out re-check and top up the pressure again. Next thing run the heating for a few minutes then re-try your water. If your getting gurggling and wooshing noises its still got air in(240 can be a pain to clear) keep turning heating/hw on and off till it quitens down and see how you get on.
The thermostat on the front is just your heating for the rads, HW is controlled on the 240's by the HW thermistor.

Gazzas86

Original Poster:

1,804 posts

202 months

Wednesday 23rd November 2011
quotequote all
Cheers Mike, i'll have a look now, try and get another pic, the right way up this time smile

Gazzas86

Original Poster:

1,804 posts

202 months

Wednesday 23rd November 2011
quotequote all


The two white pipes going off are the ones for the underfloor heating in the bathroom i take it you mean the metal flexi pipe is the one i need??

Gazzas86

Original Poster:

1,804 posts

202 months

Wednesday 23rd November 2011
quotequote all
From Left to right on the pipes, it says Central Heating Flow / Central Heating Return / Mains Cold Water In / Domestic Hot water out / Pressure Relief Discarge / Gas Service Cock,

So am i right in saying the metal braided pipe that connects from Mains Cold Water in - Central heating return, i need to open the valve on the metal braided pipe, wait for the pressure to rise, then shut it off again??

Cheers

Gaz

BIGMIKE1

339 posts

259 months

Wednesday 23rd November 2011
quotequote all
Thats the one, fills your boiler from the cold mains. Looks like the valves you have probably just has one with a screw driver slot that you turn 90degrees to fill but hard to tell without seeing the valves. You'll hear the water filling and the gauge rising as soon as you turn it. You could also do with checking none of your rads are leaking once you have the pressure up.
The 2 pipes going off to the right aren't for under floor heating, there hot and cold water.

zaphod42

60,116 posts

186 months

Wednesday 23rd November 2011
quotequote all
BIGMIKE1 said:
You could also do with checking none of your rads are leaking once you have the pressure up.
My take would be... don't do it at 11:30 at night in case something goes wrong - wait for the morning when plumbers are at least awake...

Torquey

1,961 posts

259 months

Wednesday 23rd November 2011
quotequote all
I'm surprised the boiler is running at all with the pressure that low. Mine stops working altogether when it gets below 0.5 bar.

May I suggest, once you increase the pressure keep a small eye around the radiator connections for any leaks and also on the gauge to see if drops again.

Make sure you know where the main stop cock is so you can turn everything off if it does go t1ts up tonight.

Gazzas86

Original Poster:

1,804 posts

202 months

Thursday 24th November 2011
quotequote all
Cheers for the replys guys, i'll give it a go later on when i finish work at 4pm,

Regards

Gaz

vescaegg

30,757 posts

198 months

Thursday 24th November 2011
quotequote all
Blimey OP, your situation is almost a carbon copy of the situation I was in until last week! (Bought my place in June)

Try this;

Turn the hot water temperature down on the boiler to say 1/3 of the dial. You wont notice the difference in temperature on the taps but it fixed mine which was also cutting out.

The temperature dial does not actually change the temperature of the water but regulates the flow rate. If the temp is set to max (as mine was) the flow slows down and mine kept thinking it was insufficient to keep lit. The flame went out and then re-started again (although first time unlike yours).

I turned mine down to 1/3 and problem solved - no more ball shrinkage whilst in the shower!

However, ultimately the issue isnt just this, it should stay lit even on max temperature setting. Ive investigated and think its the heat exchanger. Its a pricey bit of kit though and my bodge has worked so im leaving it be for now.

Good luck. Hope it works for you too.

By the way mine is a worcester 24cdi which is also discontinued.


P.S If you do have a leak, use this:

http://www.screwfix.com/p/fernox-superconcentrate-...


Its squeezed straight into a radiator and plugs any small holes. Worked a treat for mine which evidently has a leak somewhere I cant see!

Edited by vescaegg on Thursday 24th November 14:30

Gazzas86

Original Poster:

1,804 posts

202 months

Thursday 24th November 2011
quotequote all
vescaegg said:
Blimey OP, your situation is almost a carbon copy of the situation I was in until last week! (Bought my place in June)

Try this;

Turn the hot water temperature down on the boiler to say 1/3 of the dial. You wont notice the difference in temperature on the taps but it fixed mine which was also cutting out.

The temperature dial does not actually change the temperature of the water but regulates the flow rate. If the temp is set to max (as mine was) the flow slows down and mine kept thinking it was insufficient to keep lit. The flame went out and then re-started again (although first time unlike yours).

I turned mine down to 1/3 and problem solved - no more ball shrinkage whilst in the shower!

However, ultimately the issue isnt just this, it should stay lit even on max temperature setting. Ive investigated and think its the heat exchanger. Its a pricey bit of kit though and my bodge has worked so im leaving it be for now.

Good luck. Hope it works for you too.

By the way mine is a worcester 24cdi which is also discontinued.


P.S If you do have a leak, use this:

http://www.screwfix.com/p/fernox-superconcentrate-...


Its squeezed straight into a radiator and plugs any small holes. Worked a treat for mine which evidently has a leak somewhere I cant see!

Edited by vescaegg on Thursday 24th November 14:30
Wow, thanks for the info, I turned it down last night, I'm trying to get in touch with a local guy who my boss used to service his boiler, I'm at the very least going to get it serviced as its been 4 years since the last one, so things are probably starting to get blocked etc. I believe the service costs, (so i'm told) £50 ish. worth while i think.

cjs

11,729 posts

282 months

Thursday 24th November 2011
quotequote all
A service won't unblock any pipes, all they do is clean out the burners of any soot or deposited and check the gas for leaks.

Have you put the pressure up to 1 bar yet?