Hopefully, the plasterer is coming around on Tuesday next week to skim over Artex in our Bathroom and Kitchen, We've only been in the house for 3 weeks now and feel it looks dated, and old. We also want to change the downlighters currently installed in the kitchen/bathroom. I've put a pic below of the 'current' downlights that are fitted.
The reason for this is i believe the current ones fitted are the wrong kind when it comes to zones etc,
This is a pic of the ones fitted in the kitchen,

And this a pic of the ones fitted in the bathroom,

Can someone please clarify whether i should have the more sealed surrounds??, The pic taken from the bathroom, i have 2 lights directly above the shower and sink.
Secondly, i've been looking around, and it seems the newer models are different sizes, i.e. i'm going to have to cut a bigger hole, I've measured 62mm hole diameter for the ones in the bathroom, and 67mm in the kitchen, Is it worth cutting the holes bigger ready for the replacements before the plasterer arrives and does his handywork??
Appologies for the long post.
Regards
Gaz
Hopefully, the plasterer is coming around on Tuesday next week to skim over Artex in our Bathroom and Kitchen, We've only been in the house for 3 weeks now and feel it looks dated, and old. We also want to change the downlighters currently installed in the kitchen/bathroom. I've put a pic below of the 'current' downlights that are fitted.
The reason for this is i believe the current ones fitted are the wrong kind when it comes to zones etc,
This is a pic of the ones fitted in the kitchen,
And this a pic of the ones fitted in the bathroom,
Can someone please clarify whether i should have the more sealed surrounds??, The pic taken from the bathroom, i have 2 lights directly above the shower and sink.
Secondly, i've been looking around, and it seems the newer models are different sizes, i.e. i'm going to have to cut a bigger hole, I've measured 62mm hole diameter for the ones in the bathroom, and 67mm in the kitchen, Is it worth cutting the holes bigger ready for the replacements before the plasterer arrives and does his handywork??
Appologies for the long post.
Regards
Gaz
Cut the holes out after he has plastered, unless you know the exact Dia of the new fittings, making holes bigger is a PITA so make sure you get a good pad saw.
Fire rated fittings? As said above, I would also use them if you're installing into a loft, so that the lamps are not exposed to insulation etc. Make sure you use lamps with glass covers.
Maybe look at LEDs ??
Fire rated fittings? As said above, I would also use them if you're installing into a loft, so that the lamps are not exposed to insulation etc. Make sure you use lamps with glass covers.
Maybe look at LEDs ??
Simpo Two said:
So the ceiling isn't a zone?
Changed image as 1st one was crap. The ceiling is zoned if within the boundaries for the bath/ shower/ basin etc.. Outside of zone 2, zone 3 is a funny area. Most bathroom rated lights are zones for 1 or 2. Many lights will say 'not suitable for bathrooms'. You also can't put socket or anything like that in zone 3, but as long as it's not subject to water jets or similar, it's basicly unzoned.
I'm sure a spark will clear up Zone 3 for me.
I fitted zone one ip 65 low voltage down lighters above the shower and in the rest of the bathroom , get a trade pack from wikes or similar then you have no worries. Don't fit any sockets or light switches in the bathroom. And any thing electrical should be protected by an RCD. But as they say of on doubt get a sparky to check it. Water and electricity don't mix.
MatrixXXx said:
And any thing electrical should be protected by an RCD. But as they say of on doubt get a sparky to check it. Water and electricity don't mix.
ALL circuits in a special location now needs RCD protection, however, if the light fittings are just being replaced, there is no need.To 17th edition regs there is no longer a zone 3. It is 0,1 and 2.
Also if ceiling height is more than 2.25m above finished floor level this is classed as no zone.
I have just done my bathroom lights, IP66 lights fitted, though in my opinion IP44 would have been sufficient as my ceiling height is 2.5M.
Also if ceiling height is more than 2.25m above finished floor level this is classed as no zone.
I have just done my bathroom lights, IP66 lights fitted, though in my opinion IP44 would have been sufficient as my ceiling height is 2.5M.