Downlighter Zones advice (with pics)
Downlighter Zones advice (with pics)
Author
Discussion

Gazzas86

Original Poster:

1,804 posts

202 months

Friday 25th November 2011
quotequote all
Evening Folks,

Hopefully, the plasterer is coming around on Tuesday next week to skim over Artex in our Bathroom and Kitchen, We've only been in the house for 3 weeks now and feel it looks dated, and old. We also want to change the downlighters currently installed in the kitchen/bathroom. I've put a pic below of the 'current' downlights that are fitted.
The reason for this is i believe the current ones fitted are the wrong kind when it comes to zones etc,

This is a pic of the ones fitted in the kitchen,



And this a pic of the ones fitted in the bathroom,



Can someone please clarify whether i should have the more sealed surrounds??, The pic taken from the bathroom, i have 2 lights directly above the shower and sink.

Secondly, i've been looking around, and it seems the newer models are different sizes, i.e. i'm going to have to cut a bigger hole, I've measured 62mm hole diameter for the ones in the bathroom, and 67mm in the kitchen, Is it worth cutting the holes bigger ready for the replacements before the plasterer arrives and does his handywork??

Appologies for the long post.

Regards

Gaz

worsy

6,632 posts

206 months

Friday 25th November 2011
quotequote all
I'm no expert but the Kitchen one should be fine, the bathroom one definitely not if over the shower!

Simpo Two

93,147 posts

296 months

Friday 25th November 2011
quotequote all
Would fire-rated low voltage ones be any good?

http://www.toolstation.com/shop/Lighting/Low+Volta...

jason s4

16,810 posts

201 months

Friday 25th November 2011
quotequote all
There is no requirement to fire fire rated downlights in any room in a house, unless you are installing them in a fire barrier, eg integrated garage with room above, or flats with flats above.

The bathroom lights in your pic should be changed for suitably rated IP fittings.

cjs

11,729 posts

282 months

Saturday 26th November 2011
quotequote all
Cut the holes out after he has plastered, unless you know the exact Dia of the new fittings, making holes bigger is a PITA so make sure you get a good pad saw.

Fire rated fittings? As said above, I would also use them if you're installing into a loft, so that the lamps are not exposed to insulation etc. Make sure you use lamps with glass covers.

Maybe look at LEDs ??

Gingerbread Man

9,173 posts

244 months

Saturday 26th November 2011
quotequote all


Edited by Gingerbread Man on Saturday 26th November 18:46

Simpo Two

93,147 posts

296 months

Saturday 26th November 2011
quotequote all
So the ceiling isn't a zone?

Gingerbread Man

9,173 posts

244 months

Saturday 26th November 2011
quotequote all
Simpo Two said:
So the ceiling isn't a zone?
Changed image as 1st one was crap.

The ceiling is zoned if within the boundaries for the bath/ shower/ basin etc.. Outside of zone 2, zone 3 is a funny area. Most bathroom rated lights are zones for 1 or 2. Many lights will say 'not suitable for bathrooms'. You also can't put socket or anything like that in zone 3, but as long as it's not subject to water jets or similar, it's basicly unzoned.

I'm sure a spark will clear up Zone 3 for me.

MatrixXXx

653 posts

183 months

Sunday 27th November 2011
quotequote all
I fitted zone one ip 65 low voltage down lighters above the shower and in the rest of the bathroom , get a trade pack from wikes or similar then you have no worries. Don't fit any sockets or light switches in the bathroom. And any thing electrical should be protected by an RCD. But as they say of on doubt get a sparky to check it. Water and electricity don't mix.

jason s4

16,810 posts

201 months

Sunday 27th November 2011
quotequote all
MatrixXXx said:
And any thing electrical should be protected by an RCD. But as they say of on doubt get a sparky to check it. Water and electricity don't mix.
ALL circuits in a special location now needs RCD protection, however, if the light fittings are just being replaced, there is no need.

MatrixXXx

653 posts

183 months

Tuesday 29th November 2011
quotequote all
Sorry i meant anything you plug in ie mirrors underfloor heating etc.

Aydogflipper

436 posts

197 months

Tuesday 29th November 2011
quotequote all
To 17th edition regs there is no longer a zone 3. It is 0,1 and 2.

Also if ceiling height is more than 2.25m above finished floor level this is classed as no zone.

I have just done my bathroom lights, IP66 lights fitted, though in my opinion IP44 would have been sufficient as my ceiling height is 2.5M.