Help with ceiling light wiring
Help with ceiling light wiring
Author
Discussion

youngsyr

Original Poster:

14,742 posts

223 months

Sunday 27th November 2011
quotequote all
Hi, I've bought a new ceiling light to go on the upstairs landing of a 1930s semi, but upon taking the old light off, I'm a bit perplexed at the wiring.

The new light has two chocolate blocks attached to the wiring, one that is 3 blocks wide and has blue, brown and green/yellow wires on one side coming from the light and one single block that has no wires.

However, the existing ceiling rose (it's a "plug in" type) has 3 main cables going to it, two with red, black and green/yellow wires within them and one which seems to only have two wires, red and black, as below:



It doesn't show up that well, but the case has lettering on it showing "L" for the lefthand side set of wires and "N" for righthand side set.
So, how do I wire up the new light? confused

Z4monster

1,442 posts

291 months

Sunday 27th November 2011
quotequote all
I am NOT an Electrician but if I was replacing that rose then I would do as follows:

3 red wires blocked together not connected to anything.
Single black wire as LIVE
Two black wires as NEUTRAL
Earth to Earth (Ashes to Ashes, etc)

That's how it looks to me but I may be wrong. I'm sure someone with better knowledge than me will be along any second.

youngsyr

Original Poster:

14,742 posts

223 months

Sunday 27th November 2011
quotequote all
Z4monster said:
I am NOT an Electrician but if I was replacing that rose then I would do as follows:

3 red wires blocked together not connected to anything.
Single black wire as LIVE
Two black wires as NEUTRAL
Earth to Earth (Ashes to Ashes, etc)

That's how it looks to me but I may be wrong. I'm sure someone with better knowledge than me will be along any second.
Thanks, I've marked up the wires so will give that a shot.

If I don't report back, you know I got it wrong!

(Joke, I've turned the power off!)

youngsyr

Original Poster:

14,742 posts

223 months

Sunday 27th November 2011
quotequote all
Looks like you were right, after removing the wires, the case has writing on it for each section.

Under the 3 red wires is "LOOP", under the single black is "LINE", under the two blacks are "NEUTRAL" and the two empty ones at the end are "EARTH".

netherfield

3,226 posts

215 months

Sunday 27th November 2011
quotequote all
Now put a red sleeve or red tape on the single black wire and the job's a good one.

Brite spark

2,108 posts

232 months

Sunday 27th November 2011
quotequote all
Looks like there are 3 t+e cables there ( 3 red and 3 black singles are visible ) but there are only 2 earths visible,
You need to find the third and make sure it is connected. (really wants to be in a block rather than twisted together).

The earthing of the circuit needs to be checked, especially so if you have metal switches or light fittings.

youngsyr

Original Poster:

14,742 posts

223 months

Sunday 27th November 2011
quotequote all
Thanks all. I've now installed the light and everything is working fine.

I've used the provided chocolate blocks for the new lamp and the earth wires are connected together inside that, rather than just twisted as per the original fitting. smile


cpas

1,661 posts

271 months

Sunday 27th November 2011
quotequote all
Just a question. What have you done with the other wires? Have you connected them using a seperate junction box? What you actuall have is 2 sets of live/earth/neutral which are the loop (ie 'ring' of cables which run around the house and ate 'tapped' at each light. The cable without the earth will be a feed to the switch from live with a switched live (black) coming back to the ceiling rose. This goes into the connector next to the 'L' in the centre which is what the light fitting goes into. The 3 red wires are parmanently live so need to be safely connected and insulated.

Brite spark

2,108 posts

232 months

Monday 28th November 2011
quotequote all
cpas said:
The cable without the earth will be a feed to the switch from live with a switched live (black) coming back to the ceiling rose. The 3 red wires are parmanently live so need to be safely connected and insulated.
Its all very well the cables being properly insulated, connected and even identified as others have pointed out to the op, but the lack of the third cable not having an earth is at the moment the biggest problem here.

Op, has the earth been cut off in the cable and is there enough length on it to strip back some of the outer sheath to get the earth back and connectable if that is the case? Or have you already done this? Is the earth present at the switch?

youngsyr

Original Poster:

14,742 posts

223 months

Monday 28th November 2011
quotequote all
The 3 red wires have been connected together in one chocolate block type connection.

The two earth wires have also been connected to an Earth on the light in a chocolate block.

The cable without an Earth in the ceiling rose appears not to have one in the cable at all, I took a brief look at the cable and couldn't see one in it at all. Looking at diagrams on the net, this doesn't seem to be unusual for a switched live?

cpas

1,661 posts

271 months

Monday 28th November 2011
quotequote all
Brite spark said:
cpas said:
The cable without the earth will be a feed to the switch from live with a switched live (black) coming back to the ceiling rose. The 3 red wires are parmanently live so need to be safely connected and insulated.
Its all very well the cables being properly insulated, connected and even identified as others have pointed out to the op, but the lack of the third cable not having an earth is at the moment the biggest problem here.

Op, has the earth been cut off in the cable and is there enough length on it to strip back some of the outer sheath to get the earth back and connectable if that is the case? Or have you already done this? Is the earth present at the switch?
If the switch at the other end has a plastic face plate and plastic rear box, then there would be nowhere to connect the earth to and no need for an earth surely?

youngsyr

Original Poster:

14,742 posts

223 months

Monday 28th November 2011
quotequote all
cpas said:
Brite spark said:
cpas said:
The cable without the earth will be a feed to the switch from live with a switched live (black) coming back to the ceiling rose. The 3 red wires are parmanently live so need to be safely connected and insulated.
Its all very well the cables being properly insulated, connected and even identified as others have pointed out to the op, but the lack of the third cable not having an earth is at the moment the biggest problem here.

Op, has the earth been cut off in the cable and is there enough length on it to strip back some of the outer sheath to get the earth back and connectable if that is the case? Or have you already done this? Is the earth present at the switch?
If the switch at the other end has a plastic face plate and plastic rear box, then there would be nowhere to connect the earth to and no need for an earth surely?
All of the switches in the house have plastic face plates and from memory the one or two rear boxes I've seen are plastic too.

cpas

1,661 posts

271 months

Monday 28th November 2011
quotequote all
I will probably be wrong here, but I cannot there see why you would need an earth in this cable.

vdp1

517 posts

202 months

Saturday 3rd December 2011
quotequote all
Why assume its the switch wire without the earth, to me it has an earth looking at the photo. Its one of the loop in/out cables that is missing an earth and this should be looked further into, who knows what else is on that circuit.

Only just spotted this thread btw.

Edit to add, also looks like the dreadded white B&Q cable in there.

cpas

1,661 posts

271 months

Saturday 3rd December 2011
quotequote all
youngsyr said:
The cable without an Earth in the ceiling rose appears not to have one in the cable at all, I took a brief look at the cable and couldn't see one in it at all. Looking at diagrams on the net, this doesn't seem to be unusual for a switched live?
I wasn't assuming - I was just reading what the OP has put smile

Brite spark

2,108 posts

232 months

Saturday 3rd December 2011
quotequote all
cpas said:
I will probably be wrong here, but I cannot there see why you would need an earth in this cable.
It really is an issue in terms of the installation not complying with regulations and being potentially unsafe.

let's say the op puts in a fancy metal light fitting,
turns power off,
Removes old light,
Installs new light- all connected, including earths.
Turns power back on, breaker didn't trip so all is well...

Light comes on when the switch is switch is used, but it's a shiny fitting and has a few marks that need cleaning off...

Climbs his steps to look at the light and give it a gentle clean, at which point he receives an electric shock when he touches it.

In putting the new light up a longer screw that was used to fix the light into position has gone through the cable, as the circuit had lost it's earth at a previous point on the circuit the metal light is not earthed, screw means that the light works but the metal is also live.




vdp1 said:
Why assume its the switch wire without the earth, to me it has an earth looking at the photo. Its one of the loop in/out cables that is missing an earth and this should be looked further into, who knows what else is on that circuit.
Looks like it is one of the loop feeds missing the earth, the cable with the red/ black from the switch has an earth

vdp1

517 posts

202 months

Saturday 3rd December 2011
quotequote all



vdp1

517 posts

202 months

Saturday 3rd December 2011
quotequote all
Brite spark said:
Looks like it is one of the loop feeds missing the earth, the cable with the red/ black from the switch has an earth
Maybe you should have mentioned that on the 28th November then, instead of asking if the earth was present at the switch end.

jason s4

16,810 posts

201 months

Sunday 4th December 2011
quotequote all
In previous incarnations of house wiring, the switch drop cable never normally had a cpc.

however, current regs specify that all cables must have an earth, even if feeding something that does not require it.

As for the "white B&Q" cable.

WTF???confused

Brite spark

2,108 posts

232 months

Sunday 4th December 2011
quotequote all
vdp1 said:
Maybe you should have mentioned that on the 28th November then, instead of asking if the earth was present at the switch end.


Didn't really look to closely at the picture then, too small a screen on the phone, but asking about switches and backboxes was more of a general question than anything else. Quoted your reply as I had misread it as a could be this, rather than it is this.