can anyone tell me what this is?
can anyone tell me what this is?
Author
Discussion

rufusgti

Original Poster:

2,573 posts

223 months

Tuesday 6th December 2011
quotequote all
Booked a viewing on a property i've spotted. Just checking out the surroundings. Its the one with the large garage that backs onto some kind of compound. Does anyone recognise this, wondering if it's an electricity junction or something. Seems in an odd place?
http://maps.google.co.uk/maps?q=violet+place+cardi...

Simpo Two

93,160 posts

296 months

Tuesday 6th December 2011
quotequote all
Damn, no Street View.

Might be a subsation but whatever it is, it impedes access to the garage and that alone would make me pass.

Steffan

10,362 posts

259 months

Tuesday 6th December 2011
quotequote all
Very probably a sub station.

I would avoid the property. Substations are bad news healthwise.

rufusgti

Original Poster:

2,573 posts

223 months

Tuesday 6th December 2011
quotequote all
really? is that in the same way pylons are bad for you, depression and the like?

Thanks. I'll deffo check it out.

Steffan

10,362 posts

259 months

Tuesday 6th December 2011
quotequote all
rufusgti said:
really? is that in the same way pylons are bad for you, depression and the like?

Thanks. I'll deffo check it out.
Yes. There is believed to be very high gauss around sub stations.

As in Pylons.

I would avoid, these are definitely bad signs in this property market

rufusgti

Original Poster:

2,573 posts

223 months

Tuesday 6th December 2011
quotequote all
Steffan said:
rufusgti said:
really? is that in the same way pylons are bad for you, depression and the like?

Thanks. I'll deffo check it out.
Yes. There is believed to be very high gauss around sub stations.

As in Pylons.

I would avoid, these are definitely bad signs in this property market
Also just checked zoopla. somebody paid 146k in march for this property, looks like they've sanded the floors, fit a howdens kitchen and stuck it back on the market for 180k. Thats a little bit cheeky. Still, cant blame him for trying.

MatthewW

8 posts

211 months

Tuesday 6th December 2011
quotequote all
If you look on the council online mapping site it show it as a gas governor, they convert the high pressure mains to low pressure for domestic use - same as an electricity sub station but for gas.

normalbloke

9,018 posts

250 months

Tuesday 6th December 2011
quotequote all
It looks like the southern half is a governor, hence the vents. However the northern part of the site looks like an 11kv to 415v substation. The light coloured strip on the right side is a bank of 3 or more hv switches, and the grey box on the left is a combined transformer and LV pillar.
With regards to not buying the house because of it, ignore the horsesh@t comments, it isn't even close! Also, about one in 3 streets has one!

Sam_68

9,939 posts

276 months

Tuesday 6th December 2011
quotequote all
I'm with Normalbloke - I wouldn't be the slightest bit concerned about health risk from an electricty substation that size. Noise, maybe, if you're really sensitive to such things and it's in a very quiet location (which hardly seems to be the case in this instance?).

There's at least one on pretty much every new housing development; you can't take an electricity supply for housing more than a couple of hundred metres without one. Electricity companies prefer (it's not mandatory) to situate them at least 5 metres from a habitable room, but that's because of noise nuisance (they buzz a bit, which some people find irritating in the middle of the night if they've got windows open in summer).

I've got one major site we're about to start on with the biggest fk-off substation you've seen in your entire life on one boundary. We did a noise survey, which showed that we needed a stand-off of 30 metres to habitable rooms and acoustic vents in addition to the (standard) double glazing to reduce noise nuisance to acceptable levels, and an electromagentic field survey (which we didn't submit to Planning - it was merely held in reserve in case this sort of concern was raised as a planning objection), which showed that the field strength at the same distance was so far below the recommended limit for continuous exposure that you'd need to use scientific notation to express it as a percentage.

smile

Mr GrimNasty

8,172 posts

201 months

Tuesday 6th December 2011
quotequote all
Don't forget to check for any hum, if you are unfortunate enough to have hearing sensitive at the right frequency, they can drive you insane on a quiet night.