Underfloor Heating: problem?
Discussion
I have just had electric underfloor heating fitted in one of our bathrooms.
I turned it on for the first time today, set the temperature to 22C and left it for an hour or so.
When I returned, the thermostat indicated that the room was now heated to the required temperature.
When I entered the room, the temperature was clearly not 22C. However, the larger problem is that there are as many cold spots underfoot as there are warm ones.
Bearing in mind my ignorance of these systems, am I expecting too much or is there a problem with the installation?
Cheers
I turned it on for the first time today, set the temperature to 22C and left it for an hour or so.
When I returned, the thermostat indicated that the room was now heated to the required temperature.
When I entered the room, the temperature was clearly not 22C. However, the larger problem is that there are as many cold spots underfoot as there are warm ones.
Bearing in mind my ignorance of these systems, am I expecting too much or is there a problem with the installation?
Cheers
Depending on the thickness and what lies between the heating and the surface of the floor, it may take much longer to reach an even temperature. If you have stone or thick tile floors it can take half a day. So give it time.
Steven Quas
Hamburg
Steven Quas
Hamburg
Edited by Steven Quas on Saturday 16th March 14:53
Even with normal ceramic tiles, I would expect it to take much longer than an hour to warm the room and heat the floor evenly. Have you now had the system on for 24hrs or was it switched off after your initial test? Some of our underfloor heating takes around 12-18 hours to reach a stable temperature but the stone is around 2cm thick. Underfloor generally isn't suited to providing quick changes of temperature. I'll be interested to hear what your fitter suggests.
Steven Quas
Hamburg
Steven Quas
Hamburg
Edited by Steven Quas on Saturday 17th December 11:03
On all the heat mats I've installed, the temperature reading on the thermostat is actually the floor temperature. The room will be a fair bit cooler.
There shouldn't be any hot/cool spots as the element runs are only a few cm's apart if fitted correctly.
There shouldn't be any hot/cool spots as the element runs are only a few cm's apart if fitted correctly.
Edited by steviejasp on Saturday 17th December 19:34
steviejasp said:
On all the heat mats I've installed, the temperature reading on the thermostat is actually the floor temperature. The room will be a fair bit cooler.
There shouldn't be any hot/cool spots as the element runs are only a few cm's apart if fitted correctly.
The fitter came back yesterday and agreed that it was not functioning correctly. He could not understand why there were cold spots and confirmed that he had tested the whole thing for continuity three times prior to laying the tiles.There shouldn't be any hot/cool spots as the element runs are only a few cm's apart if fitted correctly.
Edited by steviejasp on Saturday 17th December 19:34
Also, I've noticed that despite setting the temperature on the thermostat to, say, 25C, it will never reach any higher than 21.6C.
He's coming back tomorrow after calling the supplier's tech support department.
I have electric UFH in my extension. The system has floor and ambient sensors (and I have a thermometer in the room). Couple of things I've noticed and need to plan around:
- it's definitely slower to heat up the room's air than conventional radiators
- I had those interlocking rubbery tiles on the concrete floor as a temporary measure (it's a workroom) and they were such good insulators that I had to take them up. Otherwise they just allowd the floor to get hotter without allowing the air in the room to heat up. I presume that other daft flooring/installation choices would hamper efficient UFH?
- I currently programme it via the floor temp, but may switch to programming via the air temp as I'm quite often fiddling to compensate for sunny days (e.g. quite a bit of passive solar gain through the windows)
i don't think electric u/floor heating systems are really a good substitute for rads. Hot water systems yes...but not electric.
in my opinion they are to warm the tiles underfoot and no more....and they do an excellent job of that.
people often install them to be rid of "unsightly" radiators, or to gain wall space.....nothing works as well as radiators, and also underfloor systems wreak havoc on furniture (wood) joints.
Just warm kitchen/bathroom floor tiles with it, as to heat a room would cost a bomb to run !!
in my opinion they are to warm the tiles underfoot and no more....and they do an excellent job of that.
people often install them to be rid of "unsightly" radiators, or to gain wall space.....nothing works as well as radiators, and also underfloor systems wreak havoc on furniture (wood) joints.
Just warm kitchen/bathroom floor tiles with it, as to heat a room would cost a bomb to run !!
Gassing Station | Homes, Gardens and DIY | Top of Page | What's New | My Stuff