Eliminating the cold water storage tank
Eliminating the cold water storage tank
Author
Discussion

stanwan

Original Poster:

1,995 posts

257 months

Sunday 18th December 2011
quotequote all
Hi all,

Well the homebuyer survey is back and it recommends that the boiler and cold water storage tank are replaced. Thing is, I've been used to my existing flat which has an unvented cylinder.

How feasable is it to eliminate the cold water tank altogether and replace it with an unvented hot water cylinder fed by a condenser boiler. Would solar heat pumps be a wise move? Do I need an extra cylinder/accumulator as a heat store.

Finally, any qualified phers in east Herts that want to have a go!

andy43

13,346 posts

285 months

Sunday 18th December 2011
quotequote all
Big thing - make sure your rising main can cope with whatever load you put on it - a lot of unvented cylinders or combis are thrown in without proper performance testing of the water supply.

Deva Link

26,934 posts

276 months

Sunday 18th December 2011
quotequote all
stanwan said:
Well the homebuyer survey is back and it recommends that the boiler and cold water storage tank are replaced.
Is this one of those things where whoever does the survey always says they should be replaced (like if they see a flat roof they always say it'll need replacing soon) or is there something specifically wrong with the current boiler and tank?

Anyway, getting rid of the tank and using a mains pressure hot water tank is normally easy enough, although it's ideal if the new hot water tank can go where the existing hot water cylinder is. Most people would go for a combi boiler, which doesn't have a hot tank (or cold, or course) but PH frequently rails against combi's!

Gingerbread Man

9,173 posts

244 months

Sunday 18th December 2011
quotequote all
As Deva says, I've recently read a survey for a flat my brother is about to buy, they say to replace the boiler as well. They go on age, not condition. If the cold water cistern is plastic, I bet it'll last for ages yet. It might not have a lid and be up to regs regarding the storage of potable water, but you#ll survive.

An unvented cylinder needs a good incoming main - flow rate and pressure. You might be able to start down this route and leave the boiler as is if it's still perfectly fine.

In regards to Solar/ Heat pumps. These ideally want to be used with a thermal store. You can still use a setup like this with mains hot and cold, so it could be the way to go.

Ground source heat pumps and air source heat pumps are well matched to wet underfloor heating due to the lower operating temperatures. They don't work as well with a traditional radiator central heating system.

My experience of solar hot water systems is that they're not really that great. It'll take you a long time to get your money back. If you're replacing the cylinder anyway, then this would be some of the cost, as opposed to ripping out a perfectly good cylinder.
But I don't have a great experience with them, just what manufactures have said.

Rickyy

6,618 posts

250 months

Sunday 18th December 2011
quotequote all
If it works, why replace it? The cost of installing a new system will outweigh any savings you make by installing a new boiler.

As others have said, you need a decent incoming mains with a good flow rate.

Combination boilers are ok. Plus points are mains fed hot water and instantaneous hot water.

Minus points are reliability woes compared with a conventional set up, hot water flow rate can drop dramatically if another outlet is opened if not specced correctly and they are priority hot water, so if you are a household that uses a lot of hot water in the morning, the house will not get warm!

stanwan

Original Poster:

1,995 posts

257 months

Sunday 18th December 2011
quotequote all
Rickyy said:
If it works, why replace it? The cost of installing a new system will outweigh any savings you make by installing a new boiler.

As others have said, you need a decent incoming mains with a good flow rate.

Combination boilers are ok. Plus points are mains fed hot water and instantaneous hot water.

Minus points are reliability woes compared with a conventional set up, hot water flow rate can drop dramatically if another outlet is opened if not specced correctly and they are priority hot water, so if you are a household that uses a lot of hot water in the morning, the house will not get warm!
I'm wanting instantaneous high pressure hot water from simultaneous showers/taps. I'll happily spend if it gives me what I want. Improvements t efficiency will b an added bonus.

Rickyy

6,618 posts

250 months

Sunday 18th December 2011
quotequote all
Unvented is the way to go then if you have a high demand for hot water. But make sure you get your cold main performance tested first. Unvented cylinders with low flow rate are dreadful!

Deva Link

26,934 posts

276 months

Sunday 18th December 2011
quotequote all
If the flow and pressure is iffy, and you're prepared to throw money at it, and have space, then you could use a cold water accumulator.

Rickyy

6,618 posts

250 months

Sunday 18th December 2011
quotequote all
Sorry, should add that unvented cylinders aren't instantaneous, but they retain heat well and don't take that long to heat from cold.

Gingerbread Man

9,173 posts

244 months

Sunday 18th December 2011
quotequote all
Rickyy said:
Sorry, should add that unvented cylinders aren't instantaneous, but they retain heat well and don't take that long to heat from cold.
Could setup a secondary return on the hot water circuit?

caziques

2,849 posts

199 months

Sunday 18th December 2011
quotequote all

Virtually all new houses in NZ are fitted with what is known as a mains pressure hot water cylinder - usually 300 litre. Most people heat them with electricity, in reality they can be heated with anything. The best cylinders are made of stainless steel and should last for years.

I sell solar and hot water heat pumps for these sorts of cylinders, for a new house we often fit an all in one hot water cylinder with a heat pump on top - which is then vented to outside or the roof space.

Gas heating will probably work out the easiest method in the UK, but investigate heat pumps a bit more. Air source ones are efficient these days and not hugely expensive - one I'm importing is designed for the European market and works quite happily down to -20C.

Deva Link

26,934 posts

276 months

Sunday 18th December 2011
quotequote all
caziques said:
- one I'm importing is designed for the European market and works quite happily down to -20C.
What make is that, please?

Rickyy

6,618 posts

250 months

Sunday 18th December 2011
quotequote all
Gingerbread Man said:
Could setup a secondary return on the hot water circuit?
Sorry I mean not instantaneous as in its a storage device rather than a combi boiler that heats water on demand.

Chrisgr31

14,302 posts

286 months

Sunday 18th December 2011
quotequote all
Rickyy said:
Combination boilers are ok. Plus points are mains fed hot water and instantaneous hot water.

Minus points are reliability woes compared with a conventional set up, hot water flow rate can drop dramatically if another outlet is opened if not specced correctly and they are priority hot water, so if you are a household that uses a lot of hot water in the morning, the house will not get warm!
In my experience the minus points outweigh the plus points quite considerably. Instantaneous hot water is not a great benefit as a bit of organisation ensures that you have instantaneous hot water on a tanked system. With a tamked system you have an airing cupbaord as well, can have a heated towel rail too.

sparkythecat

8,115 posts

286 months

Monday 19th December 2011
quotequote all
Chrisgr31 said:
With a tamked system you have an airing cupbaord as well, can have a heated towel rail too.
We haven't had an airing cupboard for over 20 years and I can't say I've misssed it. Given the level of insulation on modern hot water storage tanks, will it get warm in there anyway?