Battery Testing Question
Author
Discussion

sparkythecat

Original Poster:

8,115 posts

286 months

Monday 19th December 2011
quotequote all
Our local village hall, which is run on a shoestring, has a Stannah Stairlift which has stopped working.It was suggested that the batteries were probably in need of replacement and so I volunteered to investigate.
The chair contains two 7.0Ah 12v sealed lead acid batteries which I've taken out to test.

They were each showing 13.2v across the terminals and so I connected one to a 12v inspection lamp. Although the wattage of the bulb isn't marked on, when connected to one of the batteries, the lamp was drawing 3.75A
After 1 hour the lamp was still brightly lit, but after 2 hours the lamp was quite dim.

If I am correct in assuming from my test that this battery is in good health, and if the result for the second battery is the same,then both the battery and the associated charging circuit must be OK and the problem with the stairlift must lie elsewhere.

Or is my battery test not conclusive?


jeff m2

2,060 posts

182 months

Monday 19th December 2011
quotequote all
Normal way to test a battery is to charge it.
Let is sit for an hour to disperse the surface chage then do a load test (to see if it holds voltage.)

I would guess if the batteries are fully charged (and they appear to be)
a)I would look at the brushes in the motor.
b)Spray commutator with electric cleaner etc.
c)Hit side of motor.
d)Tell them your great aunt has just died.

sparkythecat

Original Poster:

8,115 posts

286 months

Monday 19th December 2011
quotequote all
Thanks Jeff. I'll put them on overnight charge and test them under load tomorrow.
There are loads of things that could be causing the lift malfunction, but I need to eliminate the battery as a problem before I start looking elsewhere.

dickymint

29,278 posts

289 months

Monday 19th December 2011
quotequote all
Jump start it!





PS. I'm not joking.