Heat source pump
Author
Discussion

crankedup

Original Poster:

25,764 posts

274 months

Saturday 24th December 2011
quotequote all
Our Son has said that its not worth spending out for a new oil storage tank,(see earlier thread). So I am investigating the new heat source pump system. Anyone in here use this system? Tips and advise sought. Thanks.

JM

3,170 posts

237 months

Saturday 24th December 2011
quotequote all
Presuming you mean a heat pump, either an air or ground source one.

Ground Source Heat Pumps are more expensive to install and require either a large garden/field or a bore hole.
Air Source Heat Pumps are cheaper to install but are slightly less efficient, especially in colder temperatures.

Both types typically deliver cooler water temperatures for heating compared to conventional boilers, so other parts of the heating system may need changing too, such as radiators or under-floor circuits. You would also probably need a new hot water cylinder.

The above is in reference to a 'wet' heating system.

The other option is an Air to Air Heat Pump, which is an air conditioning system working in reverse, but wouldn't do any hot water heating.


caziques

2,849 posts

199 months

Saturday 24th December 2011
quotequote all

More details required to give advice, but I would say you are on the right track.

It will be much easier and cheaper to go air source for a conventional radiator system - although there will be limitations - and chances are it will be cheaper to run.

The largest single phase units are 14kW output, (with say 2.5kW input), but the output figures are much reduced when it's cold outside.

One way round that is to have two outdoor units but that's getting a bit ahead.

So, location, present set up and budget constraints - I used to live in Coventry and now supply and fit all sorts of heat pumps in earthquake prone Christchurch, New Zealand.

Christmas Day, 21 degrees, warm and sunny - nearly time for a dip in the pool.

Sam_68

9,939 posts

276 months

Saturday 24th December 2011
quotequote all
JM said:
Both types typically deliver cooler water temperatures for heating compared to conventional boilers, so other parts of the heating system may need changing too, such as radiators or under-floor circuits.
^^^^ I would stress this bit, and I would suggest that it goes a lot further than 'may' need changing.

The water temperature, hence the surface temperature of the rads is much lower than is available with a conventional heating system, therefore you will need to 'oversize' the radiators to compensate.

The other aspect linked to this is that the responsiveness of a cenreal heating system that relies upon a heat pump is much worse than that of a conventionally fired C/H system. They are therefore better suited to running 24/7 in a building with a high thermal mass than intermittent running/low thermal mass.



Simpo Two

93,188 posts

296 months

Saturday 24th December 2011
quotequote all
caziques said:
Christmas Day, 21 degrees, warm and sunny - nearly time for a dip in the pool.
Git. (I was there a few years ago; a warm sunny Christmas Day didn't seem odd at all)

But remind me to laugh at you in July smile

caziques

2,849 posts

199 months

Sunday 25th December 2011
quotequote all
Great day for a swim.......

You don't have to change radiators, here's how it works.

The heat pump raises the water temperature by let's say 10 degrees. This must be the temperature drop through the radiators - if the heat pump is producing 10kW - 10kW will go into the house. As the house temp goes up, it loses more heat - until everything is in balance. It doesn't matter what temp the rads are at, they will still transfer energy. Bigger rads are more efficient as the balance temp will be lower meaning greater heat pump efficiency.

The risk is this balance will be at too low a temp to be acceptable - and it is impossible to have quick response times.

So it all depends, in a big draughty house it won't be much good. With underfloor much better.

Sam_68

9,939 posts

276 months

Sunday 25th December 2011
quotequote all
caziques said:
It doesn't matter what temp the rads are at, they will still transfer energy.
But the rate at which rads transfer energy is dependent on the difference between their surface temperature and the ambient air temperature, multiplied by their surface area.

So even in a well insulated and draugh-sealed house, you will have a very sluggish response (actually, you'll have that no matter how big your rads are, with a heat pump) and as caziques went on to say:

caziques said:
The risk is this balance will be at too low a temp to be acceptable - and it is impossible to have quick response times.

So it all depends, in a big draughty house it won't be much good. With underfloor much better.
Underfloor heating works well, of course, precisely because it does have such a large surface area to transfer the hear through.

crankedup

Original Poster:

25,764 posts

274 months

Sunday 25th December 2011
quotequote all
Some great advise, thanks guys.
Our home is a small detached 17th century timber framed cottage. Wattle and daub walls, although the gable walls are now single skin brick. Character windows (timber single glaze and drafts)Thatched roof.
So thermal insulation is zero unfortunately.
Our cottage is in Suffolk and east/west aspect.

Kudos

2,674 posts

205 months

Sunday 25th December 2011
quotequote all
How much for a new oil tank?
How much for a heat pump?

I'd estimate heat pump is more expensive by a factor of 20, not to mention increased electric bills

cuneus

5,963 posts

273 months

Sunday 25th December 2011
quotequote all
Kudos said:
How much for a new oil tank?
How much for a heat pump?

I'd estimate heat pump is more expensive by a factor of 20, not to mention increased electric bills
Please show us your detailed cost workings

Kudos

2,674 posts

205 months

Sunday 25th December 2011
quotequote all
cuneus said:
Please show us your detailed cost workings
No

cuneus

5,963 posts

273 months

Sunday 25th December 2011
quotequote all
Kudos said:
cuneus said:
Please show us your detailed cost workings
No
New tank is c. £1000 + new base + installation so on a guestimate basis not much change from say £1500

So according to you a heat pump will cost £30k rofl

and no kidding the leccy bill will increase rolleyes

caziques

2,849 posts

199 months

Monday 26th December 2011
quotequote all
http://www.wharfplumbing.co.uk/products/air-source...

Follow the link, I have something like a hundred of these units working in New Zealand. Just make sure they will provide a replacement if the heat exchanger fails (as it is prone to). They are actually selling them too cheap as they are one of the most efficient units in the world.

They use 2-2.5kW when running.

Say you have 10 radiators, on average they will each give off 1kW of energy as the unit produces about 10kW at say 10c ambient.

The OP could work out the cost of using oil and how much energy he needs as 1 litre of oil is 10kW of energy - and then work out how much a heat pump would cost to run.

The other factor could be hot water.

If you do go heat pump route make sure you fit a much more powerful circulating pump, standard ones are 99w, I always fit a 205w model. Why? Because the heat pump will last longer and is more efficient with good water flows.

Post back here if you want more technical info.

Kudos

2,674 posts

205 months

Monday 26th December 2011
quotequote all
cuneus said:
New tank is c. £1000 + new base + installation so on a guestimate basis not much change from say £1500

So according to you a heat pump will cost £30k rofl

and no kidding the leccy bill will increase rolleyes
Enlighten us, how much is a heat pump then?

cuneus

5,963 posts

273 months

Monday 26th December 2011
quotequote all
Kudos said:
cuneus said:
New tank is c. £1000 + new base + installation so on a guestimate basis not much change from say £1500

So according to you a heat pump will cost £30k rofl

and no kidding the leccy bill will increase rolleyes
Enlighten us, how much is a heat pump then?
Why are you asking? you have already deigned to tell us that they are ~30k

caziques

2,849 posts

199 months

Monday 26th December 2011
quotequote all
Sarcastic comments don't really help, not everyone is an expert in these things.

Wharf Plumbing charge 1200 + 100 for delivery for one of the best air sourced units in the world.

Installation would probably be straight forward, ones I've done have only taken a few hours.

Note you can use plastic pipe and fittings with a heat pump as it cannot get to high temperatures. The unit itself only needs standard 2.5 wiring.

Kudos

2,674 posts

205 months

Monday 26th December 2011
quotequote all
cuneus said:
Why are you asking? you have already deigned to tell us that they are ~30k
No, I didn't, you did.

Single skin oil tank, £400. Let's say £200 installation. I looked at a ground sour e heat pump with installation and was quoted over £10k, so there's the calculations.

crankedup

Original Poster:

25,764 posts

274 months

Monday 26th December 2011
quotequote all
caziques said:
http://www.wharfplumbing.co.uk/products/air-source...

Follow the link, I have something like a hundred of these units working in New Zealand. Just make sure they will provide a replacement if the heat exchanger fails (as it is prone to). They are actually selling them too cheap as they are one of the most efficient units in the world.

They use 2-2.5kW when running.

Say you have 10 radiators, on average they will each give off 1kW of energy as the unit produces about 10kW at say 10c ambient.

The OP could work out the cost of using oil and how much energy he needs as 1 litre of oil is 10kW of energy - and then work out how much a heat pump would cost to run.

The other factor could be hot water.

If you do go heat pump route make sure you fit a much more powerful circulating pump, standard ones are 99w, I always fit a 205w model. Why? Because the heat pump will last longer and is more efficient with good water flows.

Post back here if you want more technical info.
Thank you for the excellent link, If we decide to go this route, looking likely, we are thinking to site the unit some 12m or so from our cottage adjacent to the garage. We assume the units run quietly but in the dead of night perhaps its best some little way from the cottage? The feed / returns would be set underground.
Our wet system is fairly old and I would guess twenty years, would it be a good idea to replace the radiators? not looking to waste money of course but the mention of a more powerful pump prompts the question.
Thanks also to all other posters for input, much appreciated.

cuneus

5,963 posts

273 months

Monday 26th December 2011
quotequote all
Kudos said:
cuneus said:
Why are you asking? you have already deigned to tell us that they are ~30k
No, I didn't, you did.

Single skin oil tank, £400. Let's say £200 installation. I looked at a ground sour e heat pump with installation and was quoted over £10k, so there's the calculations.
You clearly did not read the other thread you posted in because if you did you would have seen the OP saying:

crankedup said:
I have seen that the plastic bunded tanks are sold for around the 1k mark, I need a bunded tank as we have a watercourse nearby.
So by your calcs we are at £1200 which times 20 is £24K for a heat pump rolleyes




crankedup

Original Poster:

25,764 posts

274 months

Monday 26th December 2011
quotequote all
Kudos said:
No, I didn't, you did.

Single skin oil tank, £400. Let's say £200 installation. I looked at a ground sour e heat pump with installation and was quoted over £10k, so there's the calculations.
Unfortunately for us our new tank would have to be double skinned as its beside a water course (farmers drainage ditch) so the cost of the tank comes in at around 1400 pounds + fitting. I agree single skin tanks are so much less expensive to buy.