Fuel Pressure Regulator Location
Fuel Pressure Regulator Location
Author
Discussion

cps13

Original Poster:

274 posts

212 months

Saturday 29th December 2012
quotequote all
Hi

I am going to put an FPR on my locost build. I am a bit confused about the location. I know it has to be up by the rail but from the reading I have done it seems people have put them on the output/return end of the rail. I would have thought it would go before the input end so that it regulates the flow before it gets to the rail/injectors.

Please can someone confirm?

thanks

stevieturbo

18,079 posts

277 months

Saturday 29th December 2012
quotequote all
The regulator can go anywhere after the pump, it doesnt really matter.

You can flow through the rail, into the reg and then out to the tank, or you can tee the reg off before the rail and run the fuel rail as a dead end, as many modern cars do now, although their regulator is actually inside the tank.

There are pro's and cons to each, but doesnt really make that much odds either way. The more common approach is to flow through the fuel rail and then to the reg.

PaulKemp

979 posts

175 months

Monday 31st December 2012
quotequote all
If fuel injected most rails will be controlled by the back pressure so the FPR is after the rail this maintains pressure in the rail to all injectors
If carbed then FPR can be after the pump in the boot or close to the carbs your choice

stevieturbo

18,079 posts

277 months

Monday 31st December 2012
quotequote all
PaulKemp said:
If fuel injected most rails will be controlled by the back pressure so the FPR is after the rail this maintains pressure in the rail to all injectors
If carbed then FPR can be after the pump in the boot or close to the carbs your choice
It can be anywhere after the pump. Most modern cars have dead end rails with a single line from tank to engine, and their regulator is in tank.

The most common setup is with the FPR after the rail, but it certainly doesnt have to be that way.