993 ac which nozzle to regas ?
993 ac which nozzle to regas ?
Author
Discussion

phib

Original Poster:

4,520 posts

289 months

Sunday 19th May 2013
quotequote all
Well I am back with my 10th 911 another 993 cab loving it !!

It had a new ac compressor in feb, but the ac is not running too cold, there are 3 valves on the ac unit and I have the gas to re gas it but which is the gas in valve ?

Thanks for help in advance

Phib

mollytherocker

14,465 posts

239 months

Sunday 19th May 2013
quotequote all
Press the left button shown below and all will be well. biggrin


phib

Original Poster:

4,520 posts

289 months

Sunday 19th May 2013
quotequote all
Very good !! That one works well on mine !!

Phib

Pope

2,653 posts

277 months

Sunday 19th May 2013
quotequote all
Doesn't sound like a standard unit; usually only have two...... High and Low pressure. Can you see any part numbers or manufacturers sticker on it?


phib

Original Poster:

4,520 posts

289 months

Sunday 19th May 2013
quotequote all
Pope said:
Doesn't sound like a standard unit; usually only have two...... High and Low pressure. Can you see any part numbers or manufacturers sticker on it?
i will have a look in the morning but it has two standard looking black caps on the valves and then another one in light grey with an L on it slightly below the other two, I had assumed one High one low and an oil drain / breather thing

Phib

phib

Original Poster:

4,520 posts

289 months

Sunday 19th May 2013
quotequote all
It looks standard ( this is not mine but its the same) tow balc ones and a grey on slightly below ( half out of shot)

Phib
[/URL]

Pickled Piper

6,452 posts

265 months

Monday 20th May 2013
quotequote all
I think the regass nozzle will only fit on one of those valves.

I could be talking total tosh, but I vaguely remember that they are different sizes.

pp

phelix

4,683 posts

279 months

Monday 20th May 2013
quotequote all
With respect - if you don't know the answer to that question you probably should not be messing around "regassing" the system.

Take the car to an AC specialist who has the right kit. Or even to kwik-fit - they hook the car up to an automated machine that extracts the gas in the system (and tells you the weight so you know how much was lost), runs a vacuum to check for leaks and then add the correct weight of gas and oil as well as a leak detecting dye. An absolute bargain at 50 quid.

phib

Original Poster:

4,520 posts

289 months

Monday 20th May 2013
quotequote all
Well that the the issue kwik fit don't know which is which either !!

Thanks

Phib

Pesty

42,655 posts

286 months

Monday 20th May 2013
quotequote all
Pickled Piper said:
I think the regass nozzle will only fit on one of those valves.

I could be talking total tosh, but I vaguely remember that they are different sizes.

pp
no you are correct. It will fit only one.

Zingari

947 posts

203 months

Monday 20th May 2013
quotequote all
A regas connects to the two 'taps' under the black covers that are uppermost in the picture - top right of the compressor. They are different sizes so you cant get it wrong. You then want 840g of R134a (likely the machine may not hold the accurate fill data)

The machine is fully automated and you must connect up both pipes from it so it can extract the gas to check the vacuum pressure for no leaks and then fill along with some green UV lube which aids to keep seals fresh and assist with identifying leaks. In the picture you can see some green stuff around the taps probably from blow back when they took the pipes off.

I know Kwik Fit fitters can come across as numb as plss stones but believe me a chimp could do it.

mollytherocker

14,465 posts

239 months

Monday 20th May 2013
quotequote all
Zingari said:
I know Kwik Fit fitters can come across as numb as plss stones but believe me a chimp could do it.
In that case, best get the manager to do it then. biggrin

fisheggs

23 posts

185 months

Wednesday 22nd May 2013
quotequote all
The R134a systems are idiot proof in terms of which connector is the low and high side. I suspect yours could be an R12 system with tyre valve type connections. In that case and in the R134a case, the fatter of the 2 pipes is the suction/low side and the thinner pipe is the discharge/high side. If filling with liquid rather than vapour, then the high side is to be used, however I would strongly advise to have system drained down first and carrying out a leak test and then a deep vacuum followed by correct oil and refrigerant. If its an R12 system then more work reqd.

SilverArrows

114 posts

161 months

Wednesday 22nd May 2013
quotequote all
You'll use the two black caps you can clearly see in the picture, ignore the grey one as you don't need to use it.
As you've had a new compressor recently but there's no/not enough gas in the system, you should have it charged with nitrogen to check for leaks. Most likely the o-ring seals on the compressor fittings have been 'pinched' when the compressor was fitted, or not replaced.
Most often when we do the A/C on old 911's we charge them up with nitrogen, run them for a few days and then check to see if the pressure has dropped because these cars often have very slow leaks.

Hope that's of some use!

phib

Original Poster:

4,520 posts

289 months

Wednesday 22nd May 2013
quotequote all
SilverArrows said:
You'll use the two black caps you can clearly see in the picture, ignore the grey one as you don't need to use it.
As you've had a new compressor recently but there's no/not enough gas in the system, you should have it charged with nitrogen to check for leaks. Most likely the o-ring seals on the compressor fittings have been 'pinched' when the compressor was fitted, or not replaced.
Most often when we do the A/C on old 911's we charge them up with nitrogen, run them for a few days and then check to see if the pressure has dropped because these cars often have very slow leaks.

Hope that's of some use!
That's brilliant and I suspect exactly the issue ( it wasn't me that changed the compressor it was the previous garage)

Many thanks

Phib