Dodgy otter switch?
Author
Discussion

voltage_maxx

Original Poster:

368 posts

239 months

Thursday 4th July 2013
quotequote all
Got home tonight and ran the engine up again biggrinbiggrinbiggrin

Engine gets up to temperature, and the fans cut in perfectly.
Engine cools and I assume all is well.

A couple of minutes later, I'm aware that the engine temperature has soared, the fans haven't cut in and there's water pouring from the header tank overflow.

Checked the fuse for the fans, and it's blown (30 Amps).

Change the fuse and the fans cut back in again, but the next 'cycle' around, they don't cut back in.

What temeprature is the standard otter switch set to come in at?
Also, where can I get a replacement? I currently have the headlight pod out, and I'm thinking it might be a good idea to change it now whilst I can.

jmorgan

36,010 posts

314 months

Thursday 4th July 2013
quotequote all
Fit an over ride switch either way. Not sure what temp the otter is, replaced mine with an aftermarket sensor in the top hose as it leaves the engine. But the over ride switch is just the two leads that go to the otter with a break/make switch to short them out.

adam quantrill

11,679 posts

272 months

Thursday 4th July 2013
quotequote all
voltage_maxx said:
there's water pouring from the header tank overflow.
It's sad when your otter dies, as it can leave a ring of bright green water on the ground....

jmorgan

36,010 posts

314 months

Thursday 4th July 2013
quotequote all
adam quantrill said:
voltage_maxx said:
there's water pouring from the header tank overflow.
It's sad when your otter dies, as it can leave a ring of bright green water on the ground....
Wonder how many get that.....

wooly350i

2,248 posts

238 months

Thursday 4th July 2013
quotequote all
I reckon I've got one spare, mail me if you want to. John.

voltage_maxx

Original Poster:

368 posts

239 months

Thursday 4th July 2013
quotequote all
wooly350i said:
I reckon I've got one spare, mail me if you want to. John.
YHM smile

Number 7

4,113 posts

292 months

Thursday 4th July 2013
quotequote all
It could be that the fan motor is starting to go, causing the fuse to blow - I had one on a 350i once that completely seized due to internal corrosion. See if it spins easily by hand (you should be able to get your fingers on it to spin it).

voltage_maxx

Original Poster:

368 posts

239 months

Thursday 4th July 2013
quotequote all
Number 7 said:
It could be that the fan motor is starting to go, causing the fuse to blow - I had one on a 350i once that completely seized due to internal corrosion. See if it spins easily by hand (you should be able to get your fingers on it to spin it).
I've just fitted these fans. They were - admittedly, off a scrap car (Audi 80 Tdi) but were in great condition, and span freely by hand and worked superbly on the bench.

I'm now thinking that they may be pulling more than 30 Amps (the rated fuse which blew) on start up.

I'll get a multimeter on it tomorrow and see how many amps they're actually pulling.
I'll probably whack a 35 or a 40 Amp fuse in there.

Wedg1e

27,038 posts

295 months

Friday 5th July 2013
quotequote all
voltage_maxx said:
I've just fitted these fans...
I'm now thinking that they may be pulling more than 30 Amps (the rated fuse which blew) on start up...
I'll get a multimeter on it tomorrow and see how many amps they're actually pulling...
That'll have to be a hell of a multimeter; most are only good for 10A...

adam quantrill

11,679 posts

272 months

Friday 5th July 2013
quotequote all
You could measure the winding resistance with the multimeter - half an ohm equates to 28A, 0.4 and it's 33A. (At such low resistances make sure you measure the multimeter leads too) When they start spinning you get back e.m.f and the current drops.

If you find it's too low how about doing a staggered startup - e.g. use 2 relays and delay one of them a few seconds (or from a second thermostat). Also 2 relays might be needed anyway depending on your relay rating. Just thought too - if you slave the second relay off the first one (so the output of the first relay drives the coil of the second) then that might give a natural delay until the first fan spins up a bit.

Edited by adam quantrill on Friday 5th July 08:18

Jack Valiant

1,894 posts

266 months

Friday 5th July 2013
quotequote all
Agree with Adam re the relay setup... this is a bit like my set up for twin fans on my 500. I have made a circuit with manual over ride with a switch as awell as an indicator LED to tell me that the fans are running in auto mode (yellow) i.e. coming on and off and manual overide (red) to remind me its on!

My fans were rated at 30A each at 100% duty cycle but they would fire th fuses from time to time. When I measured with a good quality amp meter at turn on they were drawing 32A each so up rated to 35A fuses and the jobs a good un!

Picture tells a thousand words!



Danny Hoffman

1,617 posts

292 months

Friday 5th July 2013
quotequote all
Ditto - I put twin relays on mine too, it came as standard with 2 fans so why not 2 relays?

jmorgan

36,010 posts

314 months

Friday 5th July 2013
quotequote all
Due a fan upgrade on mine, any circuit diagrams for the less lectriceried experienced that is past the standard wiring diagram?

wooly350i

2,248 posts

238 months

Friday 5th July 2013
quotequote all
If you can stretch to it the kenlowe kit is a goodun, twin fans,twin relays,twin fuses,over ride,adjustable thermostat setting ,wiring loom comes with it,doesn't use the old relays, simples as A Q would say.

jmorgan

36,010 posts

314 months

Friday 5th July 2013
quotequote all
Was going to get some spall, but just discovered me petrol tank is leaking. @rse biscuits!

wooly350i

2,248 posts

238 months

Friday 5th July 2013
quotequote all
@rse biscuits!
[/quote]
Aint heard that one before, must be uncomfortable though!

voltage_maxx

Original Poster:

368 posts

239 months

Friday 5th July 2013
quotequote all
Well, got the multimeter on the job (big old AVO meter), and sure enough there was a massive inrush current on start up which peaked at around 40Amps.
It then settled down to about 15Amps.

I've simply bunged a 40Amp fuse in to accomodate for the inrush current.
If the constant draw had been 40Amps I might have thought about putting a relay in.

I've had the fan cycling in and out mutliple times now without problem wink