Cooling system, or lack of!!!!
Cooling system, or lack of!!!!
Author
Discussion

davettf2

Original Poster:

172 posts

174 months

Thursday 7th August 2014
quotequote all
Peeps
Basically HELP. A couple weeks ago, it ran hot (120+) on the gauge within 5 miles from home, Engine hot, radiator cold. Suspected thermostat. Advice was possibly air lock. Decided that it was a good time to give the system an overhaul. Thus silicone hoses, thermostat and water pump. All the old parts looked serviceable, thus the air lock advice looked to be the culprit.
I have tried the bible way, adding the funnel to the swirl pot and jacking the front of the car up. All to no joy. It 'burps through the funnel but the engine just gets hotter and hotter and the rad stays cold. Eventually the hoses and swirl pot get hot through what I believe is convection, but the rad stays cool. It is though the water is not circulating. Also when the system is together it does not pressurise as it warms up, squeezing the top hose brings 'gurgling' noises.
I am convinced it is air in the system, but how do I get it out.

dave

PS heater is set to hot all the time and the heater seams to work!!

Trevor450

1,936 posts

177 months

Thursday 7th August 2014
quotequote all
Have you bled the radiator? If so, sounds like a blocked radiator or pipe somewhere.

caduceus

6,126 posts

295 months

Thursday 7th August 2014
quotequote all
Is there a block in the rad? Have to tried taking it out and have it pressure tested?

ianwayne

8,543 posts

297 months

Thursday 7th August 2014
quotequote all
I seem to remember a thread on here where someone found the narrow pipe from the top of their swirl pot was blocked. The hole was full of crud so the water wasn't circulating.

Adrian@

4,626 posts

311 months

Thursday 7th August 2014
quotequote all
OMG...SO funny... BUT a non contact thermometer ......

It just had to be said..as you were.
Adrian@






Chuffmeister

3,597 posts

166 months

Friday 8th August 2014
quotequote all
Have you tested the thermostat? Remove the dizzy,then the thermostat housing, take out the thermostat and place it into a cup of boiled water. If it opens, then you know it is working and you can start looking elsewhere for the problem.

It sounds as if the water isn't circulating.

Cheers
Chuffy

Colin RedGriff

2,541 posts

286 months

Friday 8th August 2014
quotequote all
Trevor450 said:
Have you bled the radiator?
This would my first thought. There should be a bleed point on the top corner of the rad. You need to loosen this off and let any air out.

davettf2

Original Poster:

172 posts

174 months

Saturday 9th August 2014
quotequote all
Peeps
Many thanks for the comments, Thermostat, hoses and water pump are all new in an attempt to solve the issue. As Chuffmeister indicates it would appear that the water is not circulating. Of concern is that all the replaced parts, thermostat and pump were serviceable. My next attempt will be to check the rad for circulation, hopefully tomorrow afternoon.
thanks again
dave

sparkythecat

8,097 posts

284 months

Saturday 9th August 2014
quotequote all
Is it possible that the old thermostat was goosed and you have put the new thermostat in upside down ?

davettf2

Original Poster:

172 posts

174 months

Sunday 10th August 2014
quotequote all
Hi Sparky
I believe the thermostat was fitted correctly, spring side into the engine block.

Hopefully if the rain stops I'll get out there this afternoon to have another play.

thanks
dave

Oldred_V8S

3,764 posts

267 months

Monday 11th August 2014
quotequote all
davettf2 said:
Many thanks for the comments, Thermostat, hoses and water pump are all new in an attempt to solve the issue. As Chuffmeister indicates it would appear that the water is not circulating.
dave
Sadly you cannot rely on a component just because it is new; there is a lot of crap out there these days. I suppose you know for sure the impeller is rotating in the new pump.

Adrian@

4,626 posts

311 months

Monday 11th August 2014
quotequote all
Serp or Pre-serp ..as the Serpentine belt can be put on the wrong way around and rotate the pump the wrong direction.
Adrian@.

Dodsy

7,175 posts

256 months

Monday 11th August 2014
quotequote all
Try running it without the thermostat to eliminate that as an issue. I had my faulty one replaced by a garage and the new one was also faulty so just because its new doesnt mean its working properly.

rigga

8,806 posts

230 months

Monday 11th August 2014
quotequote all
As Adrian says it wouldn't be the first time a serp belt had been fitted incorrectly, but the op stated it was running hot before he changed the pump and therefore removed the belt, certainly worth checking though.