Cat5 v Cat6 Cabling
Author
Discussion

ramblo93

Original Poster:

184 posts

127 months

Thursday 18th October 2018
quotequote all
The sparky is coming on Monday to start the first fix and he's asked if i want Cat5 or Cat6 cabling going from our hub to data points around the house.

I've told him Cat6 as from a quick google it seems to be for higher bandwidth (though i doubt our broadband will get fast enough to ever test this...we currently get 35mb download and hope to get upgraded to 70mb in a few months!).

Is there any reason i should be considering Cat5 instead?

thebraketester

15,850 posts

169 months

Thursday 18th October 2018
quotequote all
Whats the difference in cost between the two?

RizzoTheRat

29,164 posts

223 months

Thursday 18th October 2018
quotequote all
Might not be getting higher speeds in the next year or two, but how long do you plan to live there? 10 years ago you were probably getting less than 0.5MB, who knows what will be normal in another 10 years?

randlemarcus

13,646 posts

262 months

Thursday 18th October 2018
quotequote all
As above, ask about the price difference between the two smile Personally, would go for two Cat5 over a single Cat6, but thats just me.

xeny

5,540 posts

109 months

Thursday 18th October 2018
quotequote all
Either supports 1gbit ethernet. From wikipedia:

"10GBASE-T, or IEEE 802.3an-2006, is a standard released in 2006 to provide 10 Gbit/s connections over unshielded or shielded twisted pair cables, over distances up to 100 metres (330 ft).[43] Category 6a is required to reach the full distance of 100 metres (330 ft) and category 6 may reach a distance of 55 metres (180 ft) depending on the quality of installation, determined only after re-testing to 500 MHz."

Note that cabling to a spec that will officially support 10gig requires more care than the average person will achieve (bend radius, pinch points etc) but in reality I've got 10gig to run over poorly laid cables more often than not.

Agree with the sentiment I'd rather have 2 * cat 5 than 1 *cat 6 in most places.

Note also that 2.5g and 5g will run over cable that is to poor to work with 10g and look as if they'll be substantially cheaper to deploy at least for the next few years.

AMST09

570 posts

211 months

Thursday 18th October 2018
quotequote all
Cat 7a 👍

Durzel

13,029 posts

199 months

Thursday 18th October 2018
quotequote all
If the choice is between 2 x Cat5e and 1 x Cat6, then 2 x Cat5e.

There shouldn't be a big difference in price though really, and to be honest you should always run lots of cables even if you don't terminate them straight away. You can add more equipment at any time, but you can't replaster etc the walls easily once you've got stuff in.

Dromedary66

1,924 posts

169 months

Thursday 18th October 2018
quotequote all
Realistically 5e would suit all your listed needs.

However if I was doing this I would install shielded Cat6. Perhaps many years down the line you will want to be sending 2160p or higher HDMI signals over that cabling and 5e may not cut it for that.

Mr Pointy

13,444 posts

190 months

Thursday 18th October 2018
quotequote all
Cat6 is harder to run & install properly than Cat5e. It's thicker & stiffer & needs to be made off carefully if it's to show the benfits. All the ancilliary hardware (modular jacks, patch panels, patch cables etc) also need to be Cat6 & the parts should be compatible with each other.

Cat5e is good enough unless you plan to use the cabling to transmit HDMI video - then the additional bandwidth is useful. For network/IP traffic Cat5e is more than adequate.

Did he mean Cat6 or Cat6a? Is he using sheilded or unsheilded cable?

Mojooo

13,291 posts

211 months

Thursday 18th October 2018
quotequote all
A couple of wires aint gonna cost much difference - it might do though if its hundreds of metres.

AMST09

570 posts

211 months

Thursday 18th October 2018
quotequote all
Just chuck in cat 6 think it’s an extra £15 +VAT for 300metres
If it’s just thrown in it won’t show you any benefit, tbh I doubt you will get anywhere near it’s limitations
You can put HD down a cat5e but may be limited in 10yeas time when TVs are running 16k or something ridiculous
If the cabling is there you can use it for what you want, I have no plans to put a hdmi matrix in, but I cabled it just incase


AMST09

570 posts

211 months

Thursday 18th October 2018
quotequote all
Out of interest how much do they want to install each point? If you don’t mind me asking

ramblo93

Original Poster:

184 posts

127 months

Friday 19th October 2018
quotequote all
AMST09 said:
Out of interest how much do they want to install each point? If you don’t mind me asking
Not sure re costs per point - it was specified in the tender doc we went out to builders with (i.e. install 10 data points and cable back to central hub under the stairs).

The sparky asked me if I wanted cat5 or cat6 so the builder will picking up the tab.

Cat 6 it is then!

Thanks all

anonymous-user

85 months

Friday 19th October 2018
quotequote all
Just out of interest, why 2 x Cat 5 or 1 x Cat 6?

Is this so you can split HD video as it’s bandwidth increases?

randlemarcus

13,646 posts

262 months

Friday 19th October 2018
quotequote all
garyhun said:
Just out of interest, why 2 x Cat 5 or 1 x Cat 6?

Is this so you can split HD video as it’s bandwidth increases?
Personally, I would like two cables so I dont have to rip out the conduit when a cable goes bad smile

thebraketester

15,850 posts

169 months

Friday 19th October 2018
quotequote all
Redundancy

anonymous-user

85 months

Friday 19th October 2018
quotequote all
Ah that makes sense, thanks!

I lost one Cat 5 in my house due to either a manufacturing fault or a hungry mouse. Luckily there was a second so I should have known.