A/C compressor noise.
Discussion
Just had a brand new ac compressor fitted. It is making a terrible noise when on, which dissappear when turned off! I am, of course going to be taking it back the garage, but any idea what it could be? Low refrigerant maybe? It's like a low grinding or whiring noise that gets worse the longer it is on.
TiA
TiA
Multiple possibilities I'd say.
Firstly, is the 'new' compressor an actual brand new OEM part or a refurbished part from a local motor factor.
It could a faulty 'new' compressor, maybe the bearings, more likely if a refurbished part not done right. The noise going away when turned off because the 'load' is removed from it even though the pulley will still spin.
Otherwise it could be the belt is on to tight, or one of the tensioner/idle pulley bearings has now failed since the new compressor has been fitted.
In terms of low gas, doubt it because the system wouldn't work as the low pressure cut off would kick in. Possible I suppose though.
But, all this is guess work, just take it back and think no more off it.
Firstly, is the 'new' compressor an actual brand new OEM part or a refurbished part from a local motor factor.
It could a faulty 'new' compressor, maybe the bearings, more likely if a refurbished part not done right. The noise going away when turned off because the 'load' is removed from it even though the pulley will still spin.
Otherwise it could be the belt is on to tight, or one of the tensioner/idle pulley bearings has now failed since the new compressor has been fitted.
In terms of low gas, doubt it because the system wouldn't work as the low pressure cut off would kick in. Possible I suppose though.
But, all this is guess work, just take it back and think no more off it.
Bearings could be the culprit. Possibly knackered, or could be an incorrectly tensioned belt. As already mentioned, best taking it back as there are many possibilities.
When the old compressor was removed, how much oil was in it? Was the system oil topped back up with the amount lost?
Low refrigerant will lead to poor oil recirculation, but as mentioned previously, there will be a low pressure cut off so once the system has lost any significant quantity, it just won't run. An overcharged system with too much refrigerant can cause some excess compressor noise due to high system pressures, but that's unlikely to be noticeable unless the system is under high load.
When the old compressor was removed, how much oil was in it? Was the system oil topped back up with the amount lost?
Low refrigerant will lead to poor oil recirculation, but as mentioned previously, there will be a low pressure cut off so once the system has lost any significant quantity, it just won't run. An overcharged system with too much refrigerant can cause some excess compressor noise due to high system pressures, but that's unlikely to be noticeable unless the system is under high load.
tim0409 said:
Thread resurrection .did you ever find out what was causing the noise as I have a similar issue after a replacement compressor was fitted?
Yes I did. It was too little oil put in the new compressor. The garage that fitted it didn't follow the manufacturers guide and guessed. Good luck.21TonyK said:
I m having exactly the same with a new compressor and even swapped the old one back in with same issue. Calculating the oil level seems tricky as you may have residual oil in the system.
I have one mini which is silent and another whirring and grinding.
Yours may very well be the crank pulleyI have one mini which is silent and another whirring and grinding.
stevemcs said:
21TonyK said:
I m having exactly the same with a new compressor and even swapped the old one back in with same issue. Calculating the oil level seems tricky as you may have residual oil in the system.
I have one mini which is silent and another whirring and grinding.
Yours may very well be the crank pulleyI have one mini which is silent and another whirring and grinding.
Edited by 21TonyK on Monday 31st August 19:44
21TonyK said:
Unfortunately/fortunately the one with the knackered crank pulley is not the one whirring. But it s something that it being done on the one that is anyway as the crank seal is weeping so new seal, pulley and belt. While it s being done I ll put more PAG in the compressor. How much I m yet to work out!
If you look on NRF’s website it states how muchEdited by 21TonyK on Monday 31st August 19:44
stevemcs said:
If you look on NRF s website it states how much
I used that for reference originally as the new compressor is NRF and that had some install instructions. But…. It gets a bit unclear. The NRF compressor comes with 60ml of PAG in it. Then specifies the amount at install 135 so drain that and top it up. Then for a new condenser various sources say add 30-60 ml depending what you read. Then there’s an amount for the pipe work and evaporator if you completely clean the system. I’ve replaced the compressor and condenser with a total of 125 in the compressor but nothing in the condenser. I can only really experiment now so I am planning to add another 30 to the condenser and 30 to the condenser then regards with a gas that contains oil as well. Can only hope at this stage!! If that fails then it will be case of handing it over to an aircon specialist.