2 post car lift installation issue
2 post car lift installation issue
Author
Discussion

Woody3

Original Poster:

748 posts

234 months

Tuesday 2nd August 2022
quotequote all
Just installed a used 3 phase 2 post car lift, but we are having an issue with setting up the 'tension wire".

We are without a set of instructions or any idea of the make/model of the lift, which is far from ideal.

We have an upper and lower limit Pizzato switch on post 1.

We also have, what I'm calling a thin tension wire, that is on a separate Pizzato pulley switch. The wire is connected somewhere at the bottom of post 1, runs up to the top of the post, through the pulley switch, runs back down the post and then over to post 2 at ground level. The wire then runs up to the leg of post 2 and this is where you can set the tension.

Photos:





Here you can see the wire at ground level running parallel to the chain and then coiled up next to the leg:



Can anyone advise how to set the tension wire up correctly?

We have had the motor running intermediately, by pulling on the tension wire, but now we can't get it running at all, no matter how much will tighten or loosen the tension wire.

A link to a set of instructions of a similar design would be brilliant...

Thanks!

eltax91

10,765 posts

236 months

Tuesday 2nd August 2022
quotequote all
My lift is from Twin Busch. I'm pretty sure they are all very similar in operation. Anyway, they host all their manuals online, free to access, might be worth a look?

https://twinbusch.co.uk/shop_content.php?coID=201


ETA: It's in German, but you can see on page 17 a few pcitures on how to set tension correctly:

https://www.twinbusch.de/twimg/de/content/download...

Edited by eltax91 on Tuesday 2nd August 15:48

Woody3

Original Poster:

748 posts

234 months

Wednesday 3rd August 2022
quotequote all
Thank you - looks just what I'm after.

Will report back with how we get on.

Thanks again smile

Woody3

Original Poster:

748 posts

234 months

Friday 5th August 2022
quotequote all
All sorted.

It was just a case of setting up the tension switch properly, using a multimeter and replacing a 1 amp fuse on the PCB.

Again, thank you for your help!