10 month old Greenstar boiler no hot water
10 month old Greenstar boiler no hot water
Author
Discussion

CopperBolt

Original Poster:

969 posts

98 months

Sunday 23rd March 2025
quotequote all
As of today my boiler won’t fire to heat water. Heating works fine.
Checked the pressure gauge thing, it’s in the green ok.
Tried reset. Nothing. Powered off and on. Nothing.
No error codes displayed.

Even when heating on and boiler firing, no hot water.

Anyone any ideas?

Hoping it can be fixed under warranty pretty quickly if I can figure out who to ring.

Thanks.

miniman

30,237 posts

293 months

Sunday 23rd March 2025
quotequote all
HW zone valve.

sherman

15,345 posts

246 months

Sunday 23rd March 2025
quotequote all
Divertor valve is knackered.
Dig out your paperwork. See who you bought it from. They may sort the warranty if they are still in business or phone Greenstar in the morning.

CopperBolt

Original Poster:

969 posts

98 months

Sunday 23rd March 2025
quotequote all
Thanks. Bought via BOXT.

Will try and find a phone no in the morning.

miniman

30,237 posts

293 months

Sunday 23rd March 2025
quotequote all
Is it a complete new install, or just a new boiler?

TT86

285 posts

54 months

Sunday 23rd March 2025
quotequote all
I had similar with my Worcester green star. Had the engineer out and it actually the upstairs mixer shower valve had developed a fault and was sending cold water straight back into the system. Boiler was fine. Swapped the shower valve and was sorted.

May be worth considering.

Gren

2,030 posts

283 months

Monday 24th March 2025
quotequote all
miniman said:
HW zone valve.
That would be my guess. Takes seconds to check. A white plastic box on top of your pipework (mine is next to the HW tank). There's often a manual switch on the side that you can move by hand.

Usually 3 positions HW/CH/Both - sometimes its the motor is bust, sometimes its the valve in the pipework that's stuck. If its the former then depending on the model it can be a 15 minute DIY fix


megaphone

11,723 posts

282 months

Monday 24th March 2025
quotequote all
OP is it a Combi boiler? Or a system boiler (do you have a HW tank)?

CopperBolt

Original Poster:

969 posts

98 months

Monday 24th March 2025
quotequote all
Thanks. Bought via BOXT.

Will try and find a phone no in the morning.

CopperBolt

Original Poster:

969 posts

98 months

Monday 24th March 2025
quotequote all
megaphone said:
OP is it a Combi boiler? Or a system boiler (do you have a HW tank)?
New combi. No tanks anymore.

GasEngineer

2,335 posts

93 months

Monday 24th March 2025
quotequote all
With the heating off and the boiler not running, what happens at the boiler when you open a hot tap.

Can you hear it making any noise as if it is trying to fire? Or just the sound of water flowing through it?

OutInTheShed

14,965 posts

57 months

Monday 24th March 2025
quotequote all
To be clear, when you open a hot tap, water runs. But cold?

If so, then either the HW function of the boiler is switched off, or set to a silly low temperature, or it's broken.
It's under warranty, so don't open the box and fiddle with it.

RTFM of course!
Try turning the mains off and back on.


If no water flows from any hot taps, then the supply to the boiler is turned off, the filter is blocked, the pressure regulator valve may be duff etc.