Upstairs lighting circuit - troubleshooting

Upstairs lighting circuit - troubleshooting

Author
Discussion

omniflow

Original Poster:

3,130 posts

165 months

Our upstairs lighting circuit has tripped the circuit breaker. We've just got back from 2 weeks away, so weren't here when it happened and I have no idea what might have caused it. It's mostly standard switches, bulb holders and bulbs. There are a few 50W halogens with transformers and a couple of bathroom mirrors with inbuilt lighting.

I have tried to reset the circuit breaker, but it immediately trips again.

I don't really know where to start looking or how best to troubleshoot. Do I remove light bulbs, or would it be best to start with anything that's not a lightbulb?

Mr Pointy

12,470 posts

173 months

Is it tripping the 6amp overcurrent circut breaker or some protective device like an RCD/ELCB or RCBO? If it's the circuit breaker & it won't stay in then it's a hard short & should be easier to find. Start by removing all of the bulbs, then get at the halogen transformers & bathroom mirrors. If it's not these then it's possible a wiring issue (mice?) & you can split the loop-in/loop out of each ceiling connector to break the chain & see if the fault goes, in which case the issue is downstream from the break (lighting circuits are commonly radials not rings). If fact you could start out doing this rather than chase transformers & mirror connections.

Of course the MCB could be faulty as well but you'd have to mess about in the CU to test that.

megaphone

11,203 posts

265 months

Any outside lighting running of the circuit?

OutInTheShed

11,150 posts

40 months

Start by inspecting the loft for 'visitors'.
Tree rats chewing cables?