Gas Central Heating - Is yours on all the time?
Gas Central Heating - Is yours on all the time?
Author
Discussion

anniesdad

Original Poster:

14,589 posts

269 months

Wednesday 15th March 2006
quotequote all
At this time of the year, our heating is on permanently but set at around 17-18 degrees with the thermostatic rad valves set at between 2 & 3 notches. If it's really cold, we crank acouple of rads up to between 4 & Max until we either leave the house or go to bed. I've been advised by a couple of people that this is better to do, as the boiler is working less to maintain the heat rather than having your heating going on and off and the burners are having to work extra hard to get the house upto the temperature demanded.

I wondered, in light of the recent rises in gas prices what other PHers are doing about their heating? I must confess that I'd rather pay British Gas less money and lump the savings into the mortgage or treat the Wife/Kids to something.

regards

Steve

speedychrissie

2,994 posts

270 months

Wednesday 15th March 2006
quotequote all
at this time of year the combi is always set to medium warm for the radiators. in about a couple of months the radiators will be switched off though and it will just do taps.

i could put the combi on a timer, but it generally works fine being on all the time.

Parrot of Doom

23,075 posts

265 months

Wednesday 15th March 2006
quotequote all
I have a timer/thermostat that measures ambient air temperature, rather than water temperature. This exact model:



I can set 6 time intervals per day. In each time interval I can set the temperature I want to achieve. It never lets the boiler get to freezing point. I can also programme the weekends to a different schedule.

Costs about £25, and it will save that much money in a few short months.

All the radiators are left full on.

>> Edited by Parrot of Doom on Wednesday 15th March 17:20

>> Edited by Parrot of Doom on Wednesday 15th March 17:21

dvs_dave

9,040 posts

256 months

Wednesday 15th March 2006
quotequote all
Parrot of Doom said:
I have a timer/thermostat that measures ambient air temperature, rather than water temperature. This exact model:



I can set 6 time intervals per day. In each time interval I can set the temperature I want to achieve. It never lets the boiler get to freezing point. I can also programme the weekends to a different schedule.

Costs about £25, and it will save that much money in a few short months.

All the radiators are left full on.

>> Edited by Parrot of Doom on Wednesday 15th March 17:20

>> Edited by Parrot of Doom on Wednesday 15th March 17:21

Seconded....I don't know why all central heating systems don't already come with one of these? They're so cheap, simple and effective it's a no brainer.


>> Edited by dvs_dave on Wednesday 15th March 17:31

anniesdad

Original Poster:

14,589 posts

269 months

Wednesday 15th March 2006
quotequote all
P.O.D.

Slightly confused, with your gizmo is the boiler on permanently? You seem to suggest it is as the boiler does not reach zero ie. the ambient temperature is maintained. However you also suggest that you can have 6 settings? Might these settings be eg. 10 degrees whilst at work and then set to auto. increase at home time?

Edited: I'm an idiot, I've just re-read your post. Where do I get one and I presume it's a heating engineer required to fit it?



>> Edited by anniesdad on Wednesday 15th March 17:30

dvs_dave

9,040 posts

256 months

Wednesday 15th March 2006
quotequote all
anniesdad said:
P.O.D.

Slightly confused, with your gizmo is the boiler on permanently? You seem to suggest it is as the boiler does not reach zero ie. the ambient temperature is maintained. However you also suggest that you can have 6 settings? Might these settings be eg. 10 degrees whilst at work and then set to auto. increase at home time?

Edited: I'm an idiot, I've just re-read your post. Where do I get one and I presume it's a heating engineer required to fit it?



>> Edited by anniesdad on Wednesday 15th March 17:30


B&Q have them (there's a selection of makes/models all doing the same job). They just go in place of your current room thermostat and it's a simple DIY 2 or 3 wire job. I seem to remember the instructions being reasonably clear.

anniesdad

Original Poster:

14,589 posts

269 months

Wednesday 15th March 2006
quotequote all
dvs_dave said:
anniesdad said:
P.O.D.

Slightly confused, with your gizmo is the boiler on permanently? You seem to suggest it is as the boiler does not reach zero ie. the ambient temperature is maintained. However you also suggest that you can have 6 settings? Might these settings be eg. 10 degrees whilst at work and then set to auto. increase at home time?

Edited: I'm an idiot, I've just re-read your post. Where do I get one and I presume it's a heating engineer required to fit it?



>> Edited by anniesdad on Wednesday 15th March 17:30


B&Q have them (there's a selection of makes/models all doing the same job). They just go in place of your current room thermostat and it's a simple DIY 2 or 3 wire job. I seem to remember the instructions being reasonably clear.


The problem I might have is that my thermostat is part of the Worcester boiler itself. I don't have a seperate room thermostat.

dvs_dave

9,040 posts

256 months

Wednesday 15th March 2006
quotequote all
Hmmmm......then this isn't for you, unless you get a boiler man (no they aren't engineers ) to bang in external room thermostat wiring for you.

timmy30

9,325 posts

258 months

Wednesday 15th March 2006
quotequote all
Burning more wood. Where's me axe.......

pdV6

16,442 posts

292 months

Wednesday 15th March 2006
quotequote all
Mine's like yours AD. Much more efficient to keep the house "ticking over" rather than let it cool and then have to work hard to get back up to temp.

Note that your walls and furniture act as a heat soak, so maintaining a reasonable temperature needn't consume vast quantities of fuel.

Directly analagous to stop/start driving as opposed to cruising - you can travel the same distance in the same time but one method will use more fuel.

anniesdad

Original Poster:

14,589 posts

269 months

Wednesday 15th March 2006
quotequote all
dvs_dave said:
Hmmmm......then this isn't for you, unless you get a boiler man (no they aren't engineers ) to bang in external room thermostat wiring for you.


Thought so.

That reminds me, when I ask my Wife what she's been doing all day, she reminds me of her occupation of "Domestic Engineer". Should I suggest to her that she's not actually an engineer? Do you have a spare room that I can sleep in? LOL!

Parrot of Doom

23,075 posts

265 months

Wednesday 15th March 2006
quotequote all
anniesdad said:
P.O.D.

Slightly confused, with your gizmo is the boiler on permanently? You seem to suggest it is as the boiler does not reach zero ie. the ambient temperature is maintained. However you also suggest that you can have 6 settings? Might these settings be eg. 10 degrees whilst at work and then set to auto. increase at home time?

Edited: I'm an idiot, I've just re-read your post. Where do I get one and I presume it's a heating engineer required to fit it?



>> Edited by anniesdad on Wednesday 15th March 17:30


There is always power to the boiler - turning a boiler completely off can be catastrophic in the winter.

What happens is that the thermostat I showed you measures the air temperature in my downstairs hallway. If the air temperature passes say 23', the boiler is shut off. Now 23' might be the setting from 6pm to 12am - thats one of the time zones. The time zone from 12am to 730am might be 18' - so it is unlikely to be on during that time. From 730am - 930am, it might be 21' - then from 930 - 6pm it might be back to 19'.

The effect is that the boiler only ever comes on when the air temperature drops below a specified level. Without this type of thermostat, the boiler will only ever come on when the water temperature drops below a specific level - which can have little or no bearing on the actual room temperature.

It works out much cheaper in the end, as you're not having to faff around setting the temperature all the time - it does it for you.

Parrot of Doom

23,075 posts

265 months

Wednesday 15th March 2006
quotequote all
anniesdad said:
Where do I get one and I presume it's a heating engineer required to fit it?



>> Edited by anniesdad on Wednesday 15th March 17:30


I got mine online, but you can get them from most plumbing shops.

Installation is dead easy, just about all boiler thermostats have 2 or 3 wire switches. All this unit does is turn the boiler on and off - thats it. Mine operates using 30A twin and earth mains cable.

You can't really get the wiring wrong, if you do all that will happen is that it will turn off instead of on

anniesdad

Original Poster:

14,589 posts

269 months

Wednesday 15th March 2006
quotequote all
Why I've not got one of these fitted is beyond me! I'll be at B&Q tonight, if anybody wants me!

Parrot of Doom

23,075 posts

265 months

Wednesday 15th March 2006
quotequote all
anniesdad said:
The problem I might have is that my thermostat is part of the Worcester boiler itself. I don't have a seperate room thermostat.


Chances are if you check your boiler, there will be provision for a room thermostat - on my boiler its a big obvious block of connections, with a wiring diagram above.

As I said just now, they're very easy to set up

anniesdad

Original Poster:

14,589 posts

269 months

Wednesday 15th March 2006
quotequote all
Parrot of Doom said:


You can't really get the wiring wrong


Yes........I could.

anniesdad

Original Poster:

14,589 posts

269 months

Wednesday 15th March 2006
quotequote all
Parrot of Doom said:
anniesdad said:
The problem I might have is that my thermostat is part of the Worcester boiler itself. I don't have a seperate room thermostat.


Chances are if you check your boiler, there will be provision for a room thermostat - on my boiler its a big obvious block of connections, with a wiring diagram above.

As I said just now, they're very easy to set up


Thanks..I'm onto this.

leftie

11,838 posts

266 months

Wednesday 15th March 2006
quotequote all
dvs_dave said:
Parrot of Doom said:
I have a timer/thermostat that measures ambient air temperature, rather than water temperature. This exact model:



I can set 6 time intervals per day. In each time interval I can set the temperature I want to achieve. It never lets the boiler get to freezing point. I can also programme the weekends to a different schedule.

Costs about £25, and it will save that much money in a few short months.

All the radiators are left full on.

>> Edited by Parrot of Doom on Wednesday 15th March 17:20

>> Edited by Parrot of Doom on Wednesday 15th March 17:21

Seconded....I don't know why all central heating systems don't already come with one of these? They're so cheap, simple and effective it's a no brainer.


>> Edited by dvs_dave on Wednesday 15th March 17:31


I think it is a wiring issue. I am told that some of the more complex clocks require an extra wire to the boiler which most standard wirings don't have and siting of the thermostat is critical so you can't just stick it in a convenient spot.

paulie-mafia

3,321 posts

254 months

Wednesday 15th March 2006
quotequote all
Mine's only ever on when we're in, but The Craig (lodger), likes it quite warm so the thermostat is usually set to tropical!

Parrot of Doom

23,075 posts

265 months

Wednesday 15th March 2006
quotequote all
Leftie, the device I showed is simply a switch - it only requires 2 wires IIRC. On and off I suspect that other more complex devices can also control other aspects, such as tap water temperature etc, and require more wires