Help - how do I bleed radiators?!
Discussion
Sounds a bit odd. You might want to check that the header tank has some water in it if you have one, make sure the ballcock isn't stuck - might just be getting more air sucked in.
Other than that, bleed all the rads as you have been doing, and check if the pump has a bleed on it - ours you removed a big screw out the end of the pump. Only other thing is if the pump speed isn't right it can resonate.
>> Edited by Davi on Wednesday 22 March 20:16
Other than that, bleed all the rads as you have been doing, and check if the pump has a bleed on it - ours you removed a big screw out the end of the pump. Only other thing is if the pump speed isn't right it can resonate.
>> Edited by Davi on Wednesday 22 March 20:16
nonegreen said:
Is it a combi boiler? If so you need to top up and pressurise the system then bleed it. The noise in the pump is probably air cavitating. Technique is to pressurise, bleed then repressurise to ensure the system is full. HTH
I made this mistake at the start of the winter season.
Go top up the pressure in the water system

nonegreen said:
Is it a combi boiler? If so you need to top up and pressurise the system then bleed it. The noise in the pump is probably air cavitating. Technique is to pressurise, bleed then repressurise to ensure the system is full. HTH
Ahhhhh.... That makes sense now! Pressure needle is showing 0 bar! There are 5 identical taps underneath - time to root the manual out.
Thanks!
Beside our big boiler, there's a little expansion tank with a valve on it and a dial which is green about three-quarters of the way round, then red. Every time I bleed the radiators, I open the valve until the needle goes to the middle of the green section, then close it.
I've got no real idea what it does, but I get a great sense of DIY-satisfaction from doing it.
I've got no real idea what it does, but I get a great sense of DIY-satisfaction from doing it.

Usually there is a remmoveable pipe which fills the system from the mains water supply. I think this has to be made removable for legal reasons but often isnt disconnected. One you turn the tap, watch the needle rise and keep it within the reuired range. Don't fill it to the top of the dial as this is too much pressure when it gets hot and will blow off pressure as a safety thing.
Usually about 1.3 bar is right But see your manual. Once the pressure is back on then the hot water will work too. You may need to reset the unit by cycling the power but hopefully not.
Usually about 1.3 bar is right But see your manual. Once the pressure is back on then the hot water will work too. You may need to reset the unit by cycling the power but hopefully not.
paulie-mafia said:
Sorted - lucky find with one of the taps!
What a to-do!
Paulie - just called a mate for you but you appear to have found it anyway - he said that if the guage was at zero pressure it could also indicate a leak in the system, so to watch it carefully for a while, especially if it starts to drop again.
If your taps run hot, but your radiators dont, could be the diverter valve, they gunge up sometimes, best bet is to call a plumber..
After you have paid the hefty bill, consider coming onboard the British Gas 5 star cover, covers everything to do with your water system, even coveres replacement of leaking rads.
Well worth it.
After you have paid the hefty bill, consider coming onboard the British Gas 5 star cover, covers everything to do with your water system, even coveres replacement of leaking rads.
Well worth it.