I'm assuming the fuse has a 100A continous current rating, rather than it melting at 100A, and then melting at 200A. Does anyone know if that's correct?

pupp

12,995 posts

302 months

Friday 9th March 2007
quotequote all
It has 100A stamped on it... no idea what that actually signifies but I assume all such fuses will be rated according to a consistent system and you will be replacing like-for-like by fitting a replacement of the same marked value.

I asked the same Q a little while ago and don't think it got a definitive response.

grumbledoak

32,571 posts

263 months

Friday 9th March 2007
quotequote all
In all other areas of electrics a fuse rating is the current at which it will fail, give or take a few percent 'tolerance'. I cannot imagine the TVR 100A fuse is any different.

Paulathome

686 posts

248 months

Friday 9th March 2007
quotequote all
Andy,
A 100 amp fuse is designed to take 100 amps continuous.
However if you look more deeply into the technical side of fuses, say a mains fuse for instance they will also have a time related measurement.
ie a mains fuse rated at 13 amps may take 30 amps for 2 seconds or 50 amps for one second before it blows. It would also take maybe 100 amps for several milliseconds before failure.
Based on this information I would imagine that our 100 amp fuse would probably pass 200 or maybe three hundred amps for a couple of seconds.eek
Just my tuppence.
Cheers
Paul

puffsorted2

2,442 posts

255 months

Friday 9th March 2007
quotequote all
Dunno but if you connect jump start leads up the wrong way round like I did last week (doh!!) it melts pretty quickly hehe

Cider Andy

Original Poster:

1,889 posts

255 months

Saturday 10th March 2007
quotequote all
Thanks guys.

spend

12,581 posts

281 months

Saturday 10th March 2007
quotequote all
Try a search for something like 'UL 275' there are standards bodies that define these things if you really want a definitive answer. There are other standards, but the principles are the same.

Cider Andy

Original Poster:

1,889 posts

255 months

Saturday 10th March 2007
quotequote all
Thanks Dave.

Pasco

6,652 posts

258 months

Saturday 10th March 2007
quotequote all
Paulathome said:
Andy,
A 100 amp fuse is designed to take 100 amps continuous.
However if you look more deeply into the technical side of fuses, say a mains fuse for instance they will also have a time related measurement.
ie a mains fuse rated at 13 amps may take 30 amps for 2 seconds or 50 amps for one second before it blows. It would also take maybe 100 amps for several milliseconds before failure.
Based on this information I would imagine that our 100 amp fuse would probably pass 200 or maybe three hundred amps for a couple of seconds.eek
Just my tuppence.