Discussion
Thermostat is a right bugger to get at... it's tucked away under the inlet manifold (assuming it's a K-series Elise we're talking about?).
Unlikely to be the cause of the fan failing to come on, though, unless your car is running consistently flat cold. Even with no thermostat in place, the temperature of an Elise would eventually climb to the point where the fan should switch on, if you leave it idling long enough. What temperature range is your instrument panel typically reading when you are driving the car?
The fans on S1 Elises are prone to seizing, since they are mounted horizontally underneath the radiator where rainwater can run down onto them. First thing I would check, therefore, is that the fan is actually working - remove the relay (your owner's handbook tells you where to find the relay block and which one controls the fan) then bridge the two 'high current' terminals in the socket with a bit of wire (a bent paperclip will work fine). The fan should come on instantly and spin up rapidly. When you remove the current, it should spin down smoothly and slowly. If it doesn't come on, or it doesn't spin up and down smoothly, it's seized or partially seized. Clam-off job to replace, unfortunately.
Unlikely to be the cause of the fan failing to come on, though, unless your car is running consistently flat cold. Even with no thermostat in place, the temperature of an Elise would eventually climb to the point where the fan should switch on, if you leave it idling long enough. What temperature range is your instrument panel typically reading when you are driving the car?
The fans on S1 Elises are prone to seizing, since they are mounted horizontally underneath the radiator where rainwater can run down onto them. First thing I would check, therefore, is that the fan is actually working - remove the relay (your owner's handbook tells you where to find the relay block and which one controls the fan) then bridge the two 'high current' terminals in the socket with a bit of wire (a bent paperclip will work fine). The fan should come on instantly and spin up rapidly. When you remove the current, it should spin down smoothly and slowly. If it doesn't come on, or it doesn't spin up and down smoothly, it's seized or partially seized. Clam-off job to replace, unfortunately.

It's definitely not the themostat, then! If the thermostat had failed open (unusual - they usually fail closed) then it would run much cooler and if you did leave it idling long enough for the temperature to climb, there's no reason the fan shouldn't kick in as normal - the fan functions completely independently of the thermostat. If the thermostat had failed closed, the temperature would rise very rapidly under normal driving and the engine would boil.
84 degrees running temperature and a gradual climb in traffic indicates that your thermostat is working just fine, though... what should happen is that the temperature would gradually climb to about 103-105 degrees in traffic, then the fan would cut in and pull it back down to about 92-93 degrees before cutting out again. Obviously, your fan isn't switching on when it should...
If the fan functions fine when you short across the relay as previously described, then it's either the fan sender, the relay or the wiring that's at fault. Whatever... it will take a decent auto electrician about 10 minutes to diagnose it correctly.
Whatever you do, don't continue driving it if the temperature climbs above 105 degrees in traffic. Switch the engine OFF and allow it to cool down... you're asking for a blown head gasket allowing those sort of temperatures on a K-series!
My money would still be on it being a siezed fan, though - it's a well known and common problem on S1's.
84 degrees running temperature and a gradual climb in traffic indicates that your thermostat is working just fine, though... what should happen is that the temperature would gradually climb to about 103-105 degrees in traffic, then the fan would cut in and pull it back down to about 92-93 degrees before cutting out again. Obviously, your fan isn't switching on when it should...
If the fan functions fine when you short across the relay as previously described, then it's either the fan sender, the relay or the wiring that's at fault. Whatever... it will take a decent auto electrician about 10 minutes to diagnose it correctly.
Whatever you do, don't continue driving it if the temperature climbs above 105 degrees in traffic. Switch the engine OFF and allow it to cool down... you're asking for a blown head gasket allowing those sort of temperatures on a K-series!
My money would still be on it being a siezed fan, though - it's a well known and common problem on S1's.
Edited by Sam_68 on Thursday 26th July 00:02
Gassing Station | Elise/Exige/Europa/340R | Top of Page | What's New | My Stuff


