Upmarket Laptop with Serial and parallel port
Upmarket Laptop with Serial and parallel port
Author
Discussion

julian64

Original Poster:

14,325 posts

285 months

Friday 21st September 2007
quotequote all
Says it all really. Fed up of trying PMCIA, USB non compatible, non memory mapped serial ports.

Finding it almost impossible to find a decent laptop that'll run XP or vista, and has a conventional serial port for my work.

sadako

7,080 posts

269 months

Friday 21st September 2007
quotequote all
I don't know if this helps much but the docking stations or media slices often have the ports on them rather than the laptop. Be warned that some docks may not have them memory mapped but many are.

julian64

Original Poster:

14,325 posts

285 months

Friday 21st September 2007
quotequote all
sadako said:
I don't know if this helps much but the docking stations or media slices often have the ports on them rather than the laptop. Be warned that some docks may not have them memory mapped but many are.
Fraid that the docking stations are usually glorified USB or PMCIA ports rather than 0X3f8 type things. I would be very interested if you know of one that actually shares the bus memory with the docking station.

plasticpig

12,932 posts

256 months

Friday 21st September 2007
quotequote all
The only one I know of is the the Panasonic Toughbook CF-30. They are about £3K though IIRC.

julian64

Original Poster:

14,325 posts

285 months

Friday 21st September 2007
quotequote all
£3K eek. Can we call that plan B

bobthemonkey

4,217 posts

247 months

Friday 21st September 2007
quotequote all
julian64 said:
sadako said:
I don't know if this helps much but the docking stations or media slices often have the ports on them rather than the laptop. Be warned that some docks may not have them memory mapped but many are.
Fraid that the docking stations are usually glorified USB or PMCIA ports rather than 0X3f8 type things. I would be very interested if you know of one that actually shares the bus memory with the docking station.
The Dell business range may be suitable I think. The port connector uses some large propretiry connector, and offers serial and parallet rather than just being a glorified serial to usb converter.

dilbert

7,741 posts

262 months

Friday 21st September 2007
quotequote all
I accept that you're having compatibility problems with "USB~RS232", but in practice this shouldn't happen. Do you have any details about the software/hardware involved, because that might make it possible to solve the problem with USB~RS232 without having to find a modern laptop with legacy hardware support.

julian64

Original Poster:

14,325 posts

285 months

Friday 21st September 2007
quotequote all
Most of my projects use the 0x3f8 etc. This includes CNC machine tool stuff. An eprom blower and some BMW car diagnostic stuff that doesn't seem to work on my current laptop on various usb to RS232 adapters FDTI etc, and doesn't seem to work on a single cardbus RS232 I tried.

While your right to say it shouldn't matter if the program uses the windows API to talk to the serial port, unfortunately the serial port if often not used through the API when programs that want full control of the API are used.

dilbert

7,741 posts

262 months

Friday 21st September 2007
quotequote all
julian64 said:
Most of my projects use the 0x3f8 etc. This includes CNC machine tool stuff. An eprom blower and some BMW car diagnostic stuff that doesn't seem to work on my current laptop on various usb to RS232 adapters FDTI etc, and doesn't seem to work on a single cardbus RS232 I tried.

While your right to say it shouldn't matter if the program uses the windows API to talk to the serial port, unfortunately the serial port if often not used through the API when programs that want full control of the API are used.
As far as I am aware, if the software does not use the Win32 API, then the serial port will not work with an OS greater than Win9x, irrespective of what hardware you have. That is to say, using greater than Win9x, ie NT4, Win2K, WinXP and Vista would all prevent use of the serial port in this way. That legacy stuff used to just bash data out to the IO map, without asking first. What perhaps you may not realise is that the protection model changed all those years ago, and now when those serial port instructions execute, you just generate an exception fault. That's true for anything including and after NT4, and there is nothing that you an do about it. All the prvileges in the world won't fix that!

I suppose it's doubly frustrating, because unless you have the source code you can't point the application at a formal windows driver either. frown

I had assumed that you'd had these application/hardware combinations working on NT4 or greater, and that it was the way in which the serial port was being used, rather than the way in which the software communicates with the system, that is causing your problem.

I'd imagined that maybe the actual RS232 data channel was not being used, and that a scheme involving data being transferred over RTS/CTS, which I have seen reasonably often, was causing a problem with timings when using a USB to RS232 adapter. This problem there are solutons for.

It seems from what you're saying that it's the software and hardware thats legacy, but that the software is causing the greater problem. Maybe you should save yourself a pound or two and see if you can borrow a full on PC with serial and parallel ports that's running NT4 or later. At least it's relatively easy to find one of those. That way you can try compatibility with the operating system before forking out on a difficult to find laptop. If you go that route you can find out if it's possible that it would work, before spending the dosh.

Edited by dilbert on Friday 21st September 19:52

atom111

1,039 posts

256 months

Friday 21st September 2007
quotequote all
I have a New Toshiba Tectra A9 with built in serial put no parallel

plasticpig

12,932 posts

256 months

Friday 21st September 2007
quotequote all
julian64 said:
£3K eek. Can we call that plan B
To be fair its the only laptop I have seen that survived being dropped down a flight of stairs and you dont need to worry about spilling coffe on the keyboard. And you did ask for upmarket.


julian64

Original Poster:

14,325 posts

285 months

Saturday 22nd September 2007
quotequote all
dilbert said:
julian64 said:
Most of my projects use the 0x3f8 etc. This includes CNC machine tool stuff. An eprom blower and some BMW car diagnostic stuff that doesn't seem to work on my current laptop on various usb to RS232 adapters FDTI etc, and doesn't seem to work on a single cardbus RS232 I tried.

While your right to say it shouldn't matter if the program uses the windows API to talk to the serial port, unfortunately the serial port if often not used through the API when programs that want full control of the API are used.
As far as I am aware, if the software does not use the Win32 API, then the serial port will not work with an OS greater than Win9x, irrespective of what hardware you have. That is to say, using greater than Win9x, ie NT4, Win2K, WinXP and Vista would all prevent use of the serial port in this way. That legacy stuff used to just bash data out to the IO map, without asking first. What perhaps you may not realise is that the protection model changed all those years ago, and now when those serial port instructions execute, you just generate an exception fault. That's true for anything including and after NT4, and there is nothing that you an do about it. All the prvileges in the world won't fix that!

I suppose it's doubly frustrating, because unless you have the source code you can't point the application at a formal windows driver either. frown

I had assumed that you'd had these application/hardware combinations working on NT4 or greater, and that it was the way in which the serial port was being used, rather than the way in which the software communicates with the system, that is causing your problem.

I'd imagined that maybe the actual RS232 data channel was not being used, and that a scheme involving data being transferred over RTS/CTS, which I have seen reasonably often, was causing a problem with timings when using a USB to RS232 adapter. This problem there are solutons for.

It seems from what you're saying that it's the software and hardware thats legacy, but that the software is causing the greater problem. Maybe you should save yourself a pound or two and see if you can borrow a full on PC with serial and parallel ports that's running NT4 or later. At least it's relatively easy to find one of those. That way you can try compatibility with the operating system before forking out on a difficult to find laptop. If you go that route you can find out if it's possible that it would work, before spending the dosh.

Edited by dilbert on Friday 21st September 19:52
I take your points valid one and all, but when looking a bit into the problem most software I'm having a problem seems to try and get round the limitations of the later API operating systems by loading kernal mode / ring 0 drivers. By their very nature they ignore the API for a direct attempt at the superIO chip map locations.

In a later desperate attempt, and despite the obvious evidence, to get round my problem I loaded win95 onto my laptop. But apart from a nice trip down memory lane it did little good. frown

As my laptop has a modem built in, and remembering the architecture of older PC's I investigated the possibility of intercepting the com to modem wires, and bringing them out to the outside world via a buffer and a DB9 connector. However time has marched on, and the superio chip once identified only has the modem wirse comming out with no intermediary chip to wire onto.

dilbert

7,741 posts

262 months

Saturday 22nd September 2007
quotequote all
julian64 said:
dilbert said:
julian64 said:
Most of my projects use the 0x3f8 etc. This includes CNC machine tool stuff. An eprom blower and some BMW car diagnostic stuff that doesn't seem to work on my current laptop on various usb to RS232 adapters FDTI etc, and doesn't seem to work on a single cardbus RS232 I tried.

While your right to say it shouldn't matter if the program uses the windows API to talk to the serial port, unfortunately the serial port if often not used through the API when programs that want full control of the API are used.
As far as I am aware, if the software does not use the Win32 API, then the serial port will not work with an OS greater than Win9x, irrespective of what hardware you have. That is to say, using greater than Win9x, ie NT4, Win2K, WinXP and Vista would all prevent use of the serial port in this way. That legacy stuff used to just bash data out to the IO map, without asking first. What perhaps you may not realise is that the protection model changed all those years ago, and now when those serial port instructions execute, you just generate an exception fault. That's true for anything including and after NT4, and there is nothing that you an do about it. All the prvileges in the world won't fix that!

I suppose it's doubly frustrating, because unless you have the source code you can't point the application at a formal windows driver either. frown

I had assumed that you'd had these application/hardware combinations working on NT4 or greater, and that it was the way in which the serial port was being used, rather than the way in which the software communicates with the system, that is causing your problem.

I'd imagined that maybe the actual RS232 data channel was not being used, and that a scheme involving data being transferred over RTS/CTS, which I have seen reasonably often, was causing a problem with timings when using a USB to RS232 adapter. This problem there are solutons for.

It seems from what you're saying that it's the software and hardware thats legacy, but that the software is causing the greater problem. Maybe you should save yourself a pound or two and see if you can borrow a full on PC with serial and parallel ports that's running NT4 or later. At least it's relatively easy to find one of those. That way you can try compatibility with the operating system before forking out on a difficult to find laptop. If you go that route you can find out if it's possible that it would work, before spending the dosh.

Edited by dilbert on Friday 21st September 19:52
I take your points valid one and all, but when looking a bit into the problem most software I'm having a problem seems to try and get round the limitations of the later API operating systems by loading kernal mode / ring 0 drivers. By their very nature they ignore the API for a direct attempt at the superIO chip map locations.

In a later desperate attempt, and despite the obvious evidence, to get round my problem I loaded win95 onto my laptop. But apart from a nice trip down memory lane it did little good. frown

As my laptop has a modem built in, and remembering the architecture of older PC's I investigated the possibility of intercepting the com to modem wires, and bringing them out to the outside world via a buffer and a DB9 connector. However time has marched on, and the superio chip once identified only has the modem wirse comming out with no intermediary chip to wire onto.
Such is the beauty of VLSI.

If you have a built in modem, then you could attach it to a standalone modem, and take your RS232 on the other side of the external modem, no? Just treat it like a massive null modem!

Edited by dilbert on Saturday 22 September 15:55

julian64

Original Poster:

14,325 posts

285 months

Saturday 22nd September 2007
quotequote all
dilbert said:
julian64 said:
dilbert said:
julian64 said:
Most of my projects use the 0x3f8 etc. This includes CNC machine tool stuff. An eprom blower and some BMW car diagnostic stuff that doesn't seem to work on my current laptop on various usb to RS232 adapters FDTI etc, and doesn't seem to work on a single cardbus RS232 I tried.

While your right to say it shouldn't matter if the program uses the windows API to talk to the serial port, unfortunately the serial port if often not used through the API when programs that want full control of the API are used.
As far as I am aware, if the software does not use the Win32 API, then the serial port will not work with an OS greater than Win9x, irrespective of what hardware you have. That is to say, using greater than Win9x, ie NT4, Win2K, WinXP and Vista would all prevent use of the serial port in this way. That legacy stuff used to just bash data out to the IO map, without asking first. What perhaps you may not realise is that the protection model changed all those years ago, and now when those serial port instructions execute, you just generate an exception fault. That's true for anything including and after NT4, and there is nothing that you an do about it. All the prvileges in the world won't fix that!

I suppose it's doubly frustrating, because unless you have the source code you can't point the application at a formal windows driver either. frown

I had assumed that you'd had these application/hardware combinations working on NT4 or greater, and that it was the way in which the serial port was being used, rather than the way in which the software communicates with the system, that is causing your problem.

I'd imagined that maybe the actual RS232 data channel was not being used, and that a scheme involving data being transferred over RTS/CTS, which I have seen reasonably often, was causing a problem with timings when using a USB to RS232 adapter. This problem there are solutons for.

It seems from what you're saying that it's the software and hardware thats legacy, but that the software is causing the greater problem. Maybe you should save yourself a pound or two and see if you can borrow a full on PC with serial and parallel ports that's running NT4 or later. At least it's relatively easy to find one of those. That way you can try compatibility with the operating system before forking out on a difficult to find laptop. If you go that route you can find out if it's possible that it would work, before spending the dosh.

Edited by dilbert on Friday 21st September 19:52
I take your points valid one and all, but when looking a bit into the problem most software I'm having a problem seems to try and get round the limitations of the later API operating systems by loading kernal mode / ring 0 drivers. By their very nature they ignore the API for a direct attempt at the superIO chip map locations.

In a later desperate attempt, and despite the obvious evidence, to get round my problem I loaded win95 onto my laptop. But apart from a nice trip down memory lane it did little good. frown

As my laptop has a modem built in, and remembering the architecture of older PC's I investigated the possibility of intercepting the com to modem wires, and bringing them out to the outside world via a buffer and a DB9 connector. However time has marched on, and the superio chip once identified only has the modem wirse comming out with no intermediary chip to wire onto.
Such is the beauty of VLSI.

If you have a built in modem, then you could attach it to a standalone modem, and take your RS232 on the other side of the external modem, no? Just treat it like a massive null modem!

Edited by dilbert on Saturday 22 September 15:55
Good idea with one slight flaw smile. The modems use the RTS CTS handshaking for their own benefit and thus nothing would appear to the handshaking lines after the null modem in terms of control lines.

dilbert

7,741 posts

262 months

Saturday 22nd September 2007
quotequote all
julian64 said:
dilbert said:
julian64 said:
dilbert said:
julian64 said:
Most of my projects use the 0x3f8 etc. This includes CNC machine tool stuff. An eprom blower and some BMW car diagnostic stuff that doesn't seem to work on my current laptop on various usb to RS232 adapters FDTI etc, and doesn't seem to work on a single cardbus RS232 I tried.

While your right to say it shouldn't matter if the program uses the windows API to talk to the serial port, unfortunately the serial port if often not used through the API when programs that want full control of the API are used.
As far as I am aware, if the software does not use the Win32 API, then the serial port will not work with an OS greater than Win9x, irrespective of what hardware you have. That is to say, using greater than Win9x, ie NT4, Win2K, WinXP and Vista would all prevent use of the serial port in this way. That legacy stuff used to just bash data out to the IO map, without asking first. What perhaps you may not realise is that the protection model changed all those years ago, and now when those serial port instructions execute, you just generate an exception fault. That's true for anything including and after NT4, and there is nothing that you an do about it. All the prvileges in the world won't fix that!

I suppose it's doubly frustrating, because unless you have the source code you can't point the application at a formal windows driver either. frown

I had assumed that you'd had these application/hardware combinations working on NT4 or greater, and that it was the way in which the serial port was being used, rather than the way in which the software communicates with the system, that is causing your problem.

I'd imagined that maybe the actual RS232 data channel was not being used, and that a scheme involving data being transferred over RTS/CTS, which I have seen reasonably often, was causing a problem with timings when using a USB to RS232 adapter. This problem there are solutons for.

It seems from what you're saying that it's the software and hardware thats legacy, but that the software is causing the greater problem. Maybe you should save yourself a pound or two and see if you can borrow a full on PC with serial and parallel ports that's running NT4 or later. At least it's relatively easy to find one of those. That way you can try compatibility with the operating system before forking out on a difficult to find laptop. If you go that route you can find out if it's possible that it would work, before spending the dosh.

Edited by dilbert on Friday 21st September 19:52
I take your points valid one and all, but when looking a bit into the problem most software I'm having a problem seems to try and get round the limitations of the later API operating systems by loading kernal mode / ring 0 drivers. By their very nature they ignore the API for a direct attempt at the superIO chip map locations.

In a later desperate attempt, and despite the obvious evidence, to get round my problem I loaded win95 onto my laptop. But apart from a nice trip down memory lane it did little good. frown

As my laptop has a modem built in, and remembering the architecture of older PC's I investigated the possibility of intercepting the com to modem wires, and bringing them out to the outside world via a buffer and a DB9 connector. However time has marched on, and the superio chip once identified only has the modem wirse comming out with no intermediary chip to wire onto.
Such is the beauty of VLSI.

If you have a built in modem, then you could attach it to a standalone modem, and take your RS232 on the other side of the external modem, no? Just treat it like a massive null modem!

Edited by dilbert on Saturday 22 September 15:55
Good idea with one slight flaw smile. The modems use the RTS CTS handshaking for their own benefit and thus nothing would appear to the handshaking lines after the null modem in terms of control lines.
Aha.....

But this would suggest that a custom driver could be written, because it implictily suggests that you think the modem would work if only you could "get at the pins" of the VLSI absorbed IO chip. hehe Look, you havn't even said what sort of flow control you need to operate, if any, or even if the data port is actually used.

I don't know. I can't help you. If I were you, I'd get a spanking ruggedised flaptop with a serial and printer port, and see if it works with Vista! I don't fancy your chances much though if it won't work with Win95!

Good luck, and happy hunting! (I should think that Google is your friend)
smile

Edited by dilbert on Saturday 22 September 22:31

ywouldi

765 posts

268 months

Sunday 23rd September 2007
quotequote all
dilbert said:
julian64 said:
dilbert said:
julian64 said:
dilbert said:
julian64 said:
Most of my projects use the 0x3f8 etc. This includes CNC machine tool stuff. An eprom blower and some BMW car diagnostic stuff that doesn't seem to work on my current laptop on various usb to RS232 adapters FDTI etc, and doesn't seem to work on a single cardbus RS232 I tried.

While your right to say it shouldn't matter if the program uses the windows API to talk to the serial port, unfortunately the serial port if often not used through the API when programs that want full control of the API are used.
As far as I am aware, if the software does not use the Win32 API, then the serial port will not work with an OS greater than Win9x, irrespective of what hardware you have. That is to say, using greater than Win9x, ie NT4, Win2K, WinXP and Vista would all prevent use of the serial port in this way. That legacy stuff used to just bash data out to the IO map, without asking first. What perhaps you may not realise is that the protection model changed all those years ago, and now when those serial port instructions execute, you just generate an exception fault. That's true for anything including and after NT4, and there is nothing that you an do about it. All the prvileges in the world won't fix that!

I suppose it's doubly frustrating, because unless you have the source code you can't point the application at a formal windows driver either. frown

I had assumed that you'd had these application/hardware combinations working on NT4 or greater, and that it was the way in which the serial port was being used, rather than the way in which the software communicates with the system, that is causing your problem.

I'd imagined that maybe the actual RS232 data channel was not being used, and that a scheme involving data being transferred over RTS/CTS, which I have seen reasonably often, was causing a problem with timings when using a USB to RS232 adapter. This problem there are solutons for.

It seems from what you're saying that it's the software and hardware thats legacy, but that the software is causing the greater problem. Maybe you should save yourself a pound or two and see if you can borrow a full on PC with serial and parallel ports that's running NT4 or later. At least it's relatively easy to find one of those. That way you can try compatibility with the operating system before forking out on a difficult to find laptop. If you go that route you can find out if it's possible that it would work, before spending the dosh.

Edited by dilbert on Friday 21st September 19:52
I take your points valid one and all, but when looking a bit into the problem most software I'm having a problem seems to try and get round the limitations of the later API operating systems by loading kernal mode / ring 0 drivers. By their very nature they ignore the API for a direct attempt at the superIO chip map locations.

In a later desperate attempt, and despite the obvious evidence, to get round my problem I loaded win95 onto my laptop. But apart from a nice trip down memory lane it did little good. frown

As my laptop has a modem built in, and remembering the architecture of older PC's I investigated the possibility of intercepting the com to modem wires, and bringing them out to the outside world via a buffer and a DB9 connector. However time has marched on, and the superio chip once identified only has the modem wirse comming out with no intermediary chip to wire onto.
Such is the beauty of VLSI.

If you have a built in modem, then you could attach it to a standalone modem, and take your RS232 on the other side of the external modem, no? Just treat it like a massive null modem!

Edited by dilbert on Saturday 22 September 15:55
Good idea with one slight flaw smile. The modems use the RTS CTS handshaking for their own benefit and thus nothing would appear to the handshaking lines after the null modem in terms of control lines.
Aha.....

But this would suggest that a custom driver could be written, because it implictily suggests that you think the modem would work if only you could "get at the pins" of the VLSI absorbed IO chip. hehe Look, you havn't even said what sort of flow control you need to operate, if any, or even if the data port is actually used.

I don't know. I can't help you. If I were you, I'd get a spanking ruggedised flaptop with a serial and printer port, and see if it works with Vista! I don't fancy your chances much though if it won't work with Win95!

Good luck, and happy hunting! (I should think that Google is your friend)
smile

Edited by dilbert on Saturday 22 September 22:31
Have you turned it off and on again?

julian64

Original Poster:

14,325 posts

285 months

Monday 24th September 2007
quotequote all
atom111 said:
I have a New Toshiba Tectra A9 with built in serial put no parallel
Good post, nearly missed this in the other conversation. Hopefully ordering an A105 next week.

Thank you.

sadako

7,080 posts

269 months

Monday 24th September 2007
quotequote all
julian64 said:
sadako said:
I don't know if this helps much but the docking stations or media slices often have the ports on them rather than the laptop. Be warned that some docks may not have them memory mapped but many are.
Fraid that the docking stations are usually glorified USB or PMCIA ports rather than 0X3f8 type things. I would be very interested if you know of one that actually shares the bus memory with the docking station.
One of the models we are using at this site is the HP nc6400. As far as I can tell the laptop has serial and parallel in it but no physical ports, and the dock is a full port replicator. Unfortunately I've just changed to a different role so i'm not handling them as much to doublecheck. I do know that the dock for this model recently had a recall from a manufacturing fault so getting one is not easy right now.