Earth connection
Author
Discussion

vixen

Original Poster:

332 posts

307 months

Sunday 18th November 2007
quotequote all
I have my chassis sandblasted and powdercoated.
If I want to make earth connections to the chassis for electric cables must I then remove the powder coating to bare metal? If I am right the powder coating is some kind of "plastic".

Sam_68

9,939 posts

269 months

Sunday 18th November 2007
quotequote all
Yes, you need metal-to-metal contact for the earth.

tribbles

4,144 posts

246 months

Sunday 18th November 2007
quotequote all
What you can do is weld some bolts to the chassis. Before going to powder coating, cover them with masking tape, so when you get it back, you remove the tape to leave your bolt exposed.

On mine, because the chassis came powder coated, I had to grind it away, weld the bolt on, and then paint over the welds.

grahambell

2,720 posts

299 months

Monday 19th November 2007
quotequote all
If the chassis is thick enough (3mm) you might get away with drilling and tapping it either M6 or 1/4" UNF and bolting your earth connection to that.