Tamora - intermittent internal fan
Discussion
Hi Richard.
I've noticed the same problem on mine, but as it kicks in i have'nt
given it much thought as the heating system on my Tam is not what i
would call brilliant, red dot hot on mine is about 75% of what i
would like it to be, just had a new rad fitted so i'll see if that
improves things, be interesting to hear what other Tamora owners think
if a thread gets going here, BTW how did your car limits day go.
Ken.
I've noticed the same problem on mine, but as it kicks in i have'nt
given it much thought as the heating system on my Tam is not what i
would call brilliant, red dot hot on mine is about 75% of what i
would like it to be, just had a new rad fitted so i'll see if that
improves things, be interesting to hear what other Tamora owners think
if a thread gets going here, BTW how did your car limits day go.
Ken.
Hi Ken
Thanks for your response.Went out yesterday and after nailing it through a series of short dual carriageway/roundabout sections and back the fan appeared to work.
Car limits was a fantastic day, spinning all over the place! All for £44. Great value.
Enjoy spain, see you on the trackdays.
New suspension next week!
Thanks for your response.Went out yesterday and after nailing it through a series of short dual carriageway/roundabout sections and back the fan appeared to work.
Car limits was a fantastic day, spinning all over the place! All for £44. Great value.
Enjoy spain, see you on the trackdays.
New suspension next week!
My fan is intermittent to. The regulator circuit board is situated under the parcel shelve on the passenger side. It is right at the back and hard to get to, but I sometimes manage to get a hand to it and waggle the wire around till the fan starts working again. Must be a dry joint on the circuit board somewhere
.
.icraigmy said:
The regulator circuit board is situated under the parcel shelve on the passenger side. It is right at the back and hard to get to, but I sometimes manage to get a hand to it and waggle the wire around till the fan starts working again. Must be a dry joint on the circuit board somewhere
.
.
Think its a dry joint that gives up after is being on for a while.
Un plug it for a couple of minutes to cool; careful it will be hot, then it will work again OK.

I moved mine into the cool air flow in the lower dash, and its only happened once since after 3 hours hot driving.

Hope this helps