Oil rig question....
Author
Discussion

Mactac

Original Poster:

645 posts

224 months

Saturday 19th April 2008
quotequote all
How are they powered ?

For some reason the image of One lit up like a Christmas tree at night has just popped into my head, I know there are rig-worker members here so...


Surely generators would be insufficent For: light/heat/drilling etc.

matchmaker

9,091 posts

231 months

Saturday 19th April 2008
quotequote all
Generators...............in the middle of the North Sea how else?

Mactac

Original Poster:

645 posts

224 months

Saturday 19th April 2008
quotequote all
Honestly no idea, but as there are pipes to collect the oil or gas going ashore, I wondered if they got 'hooked up' given the juice they must need.


Cheers anyway

B17NNS

18,506 posts

278 months

Saturday 19th April 2008
quotequote all
A typical oil production platform is self-sufficient in energy and water needs, housing electrical generation, water desalinators and all of the equipment necessary to process oil and gas such that it can be either delivered directly onshore by pipeline or to a Floating Storage Unit and/or tanker loading facility. Elements in the oil/gas production process include wellhead, production manifold, production separator, glycol process to dry gas, gas compressors, water injection pumps, oil/gas export metering and main oil line pumps. All production facilities are designed to have minimal environmental impact.

http://en.wikipedia.org/wiki/Oil_rig

Mactac

Original Poster:

645 posts

224 months

Saturday 19th April 2008
quotequote all
Obviously I'm going to ask what they are burning off
so flamboyantly like an 'olympic torch' poking ou the side, on every occasion I see them on telly..

Edited by Mactac on Saturday 19th April 20:40

Kiltie

7,505 posts

277 months

Saturday 19th April 2008
quotequote all
OK, first thing is to sort out some terminology here. The term 'rig' is often, incorrectly, used to describe any 'installation'. For me, a 'rig' is a mobile (drilling) unit (jack-up or semi-submersible).

So, rigs are powered by by diesel generators. The diesel is delivered by supply vessel and stored in bulk tanks.

Fixed installations (platforms, semi's and FPSO's)are mostly purely for production and export (but may have a permanent drilling facility incorporated in the topside. These are almost all powered by on-board generation. The difference is that in many cases, the generators burn produced gas (separated on-board in the process plant).

Some smaller installations (like not normally manned platforms) may be powered from a host facility via a power cable installed on the seabed.

In the North Sea, the only exception I can think of is the Beryl 'A' platform currently operated by Ithaca Energy (recently aquired from Talisman). The (fixed) platform is in the Moray Forth and is close enough to shore that it is powered via a cable to shore and (I think) the national grid.

Cheers,

Eric smile

halo25

2,890 posts

230 months

Saturday 19th April 2008
quotequote all
Kiltie said:
OK, first thing is to sort out some terminology here. The term 'rig' is often, incorrectly, used to describe any 'installation'. For me, a 'rig' is a mobile (drilling) unit (jack-up or semi-submersible).

So, rigs are powered by by diesel generators. The diesel is delivered by supply vessel and stored in bulk tanks.

Fixed installations (platforms, semi's and FPSO's)are mostly purely for production and export (but may have a permanent drilling facility incorporated in the topside. These are almost all powered by on-board generation. The difference is that in many cases, the generators burn produced gas (separated on-board in the process plant).

Some smaller installations (like not normally manned platforms) may be powered from a host facility via a power cable installed on the seabed.

In the North Sea, the only exception I can think of is the Beryl 'A' platform currently operated by Ithaca Energy (recently aquired from Talisman). The (fixed) platform is in the Moray Forth and is close enough to shore that it is powered via a cable to shore and (I think) the national grid.

Cheers,

Eric smile
Ahh so thats the big thing I can see from my window right now smile

Mactac

Original Poster:

645 posts

224 months

Saturday 19th April 2008
quotequote all
Cheers for that Eric.

I suppose that thread on an 'installation' being evacuated the other month on here made me think, as someone said the thing was a series of 'rigs?' Joined together in a row.


Sounded like a small town.

Kiltie

7,505 posts

277 months

Saturday 19th April 2008
quotequote all
Bugger, I said 'Beryl' - I meant 'Beatrice'.

Sorry.

Cheers,

Eric smile

Mactac

Original Poster:

645 posts

224 months

Saturday 19th April 2008
quotequote all
Halo, is it lit up, can we have a picture?

halo25

2,890 posts

230 months

Saturday 19th April 2008
quotequote all
Mactac said:
Halo, is it lit up, can we have a picture?
Few houses in the way mate, will try and get one tomorrow when I am out and about!

The amount of noise they make at night I assume the generators are running.

Kiltie

7,505 posts

277 months

Saturday 19th April 2008
quotequote all


I understand it has a few wind turbines round it nowadays.

Cheers,

Eric smile

p.s. I have to peel the potatoes now - I'll get on to flaring later.

halo25

2,890 posts

230 months

Saturday 19th April 2008
quotequote all
PS if anyone can host a couple of pics for me I have some of the rigs in the Moray Firth lit up like Xmas trees...

Mactac

Original Poster:

645 posts

224 months

Saturday 19th April 2008
quotequote all
So is noise a real problem with them?

I know even on holiday on the coast (thinking about it) you can get woken by fishing boats on their way out first thing as the sound carries across water,

never have thought about the 'rig' type stuff before now

King Herald

23,501 posts

247 months

Saturday 19th April 2008
quotequote all
Mactac said:
Cheers for that Eric.

I suppose that thread on an 'installation' being evacuated the other month on here made me think, as someone said the thing was a series of 'rigs?' Joined together in a row.


Sounded like a small town.
Maybe this one? A series of installations connected together, with several helidecks, cranes, accommodation modules etc. I took this in the North sea a couple of years ago.



It's not lit up because, er, its daylight smile

halo25

2,890 posts

230 months

Saturday 19th April 2008
quotequote all


Olf

11,978 posts

249 months

Saturday 19th April 2008
quotequote all
polus said:
Mactac said:
Obviously I'm going to ask what they are burning off
so flamboyantly like an 'olympic torch' poking ou the side, on every occasion I see them on telly..

Edited by Mactac on Saturday 19th April 20:40
I was under the impression is was excess gas that had to be released to stop pressure building up to a dangerous level, and you cant just release it, so it gets burnt.

...Waits for someone to correct mesmile
What you are talking about is flaring. Gas or product or whatever you want to call it is flared for a variety of reasons namely:

Planned flaring due to ongoing operations. All oil/gas processing has some extent of controlled flash gas loss that can't be used at the pressures they boil off and also clean gas is often used as a utility to purge systems of air or whatever. You have some choices about what you do with this, you either burn it (the flare) or you re-compress this flash gas and push it back into the processing train. The problem is that this requires extra equipment (bad offshore) and is an energy overhead.

During maintenance or shut down or star-up of a oil and gas processing train gas is always produced either too quickly, to slowly out of sync or you just have to dump an inventory already present that might be off-spec or difficult to do anything else with. Pretty mich your only choice in an isolated facility is to flare this off.

Finally in the event of an emergency a plant will shut down automatically in a pre-programmed controlled fashion (well thats the plan) when this happens emergency shut down valves will act and the facility will blow-down to the flare. Subsequently the plant should be left in a safe condition and if there is a fire the inventory should be minimised to reduce fire risk.

The extent of flaring you'll see generally depends on the field and the gas to oil ratio therein. Considering that oil is the pay dirt or gold or always has been, gas used to be a troublesome by product then if the oil came up with a load of gas you had to flare it.

In some places namely Norway, they have tried to eliminate ongoing flaring altogether, meaning they'd only flare in an emergency which is great. Until you need to light the bloody thing in an emergency!

Thats basically it in laymans terms. Someone who knows more than me will probably pick up on something I've missed.

Mactac

Original Poster:

645 posts

224 months

Saturday 19th April 2008
quotequote all
Thanks,

Knew I'd get a response this evening
PH has been a playground all afternoon,
+ you lot can't resist a technical question

(Thank god)

Olf

11,978 posts

249 months

Saturday 19th April 2008
quotequote all
halo25 said:

If I'm right the one on the right in the first photo and in the second photo is a semi submersible drilling rig and the one on the left in the first photo is jack-up drilling rig used in shallow waters.

Offshore is not my game.

Edited by Olf on Saturday 19th April 21:36

Kiltie

7,505 posts

277 months

Saturday 19th April 2008
quotequote all
Right, that's the tatties on. smile

Olf has covered everything (and sounds like a process engineer wink). The only thing I'd ad is that flaring (in the UKCS) is strictly controlled. Operator companies have to negotiate an annual flaring consent with the authorities (primarily the DTi).

Exceeding figures in the consent is a matter treated with a great deal of gravity.

Olf mentions geting the flare lit in an emergency. I think they mostly have some sort of pilot light arrangement. When this goes out however it means someone is in for a bit of fun as the conventional method for re-lighting the flare is shooting a firework into the vented gas at the flare tip.

Working on a diving or construction vessel (my roots) underneath a flare can be interesting. On some older installations with constant flaring, I remember being out on the bridge wings like being on Mediterranean beach at midday in the Summer. I remember an instance where the plant tripped and the flare went to full pelt without the platform letting the boat know. It melted the fast rescue boat (which had a full tank of fuel!) - close one. Then there's the isue of liquid carry-over if the flare train isn't working efficiently (Olf - knockout drums?) It has been known for big globs of boiling pitch to land on a vessel's deck.

Cheers,

Eric smile