Showerheads - Washing Matters
Discussion
To the PH Plumbers.
The house has a fixed showerhead shower. (e.g. not on a hose)
The head a bit rubbish no limescale has got into the wrong places and pushed bits apart.
So down to Focus (I say to focus I mean Homebase(none) to Wicks(none)), we go and buy a new head....
"standard 1/2inch" fitting it says. Excellent thinks I. Only one option must all be the same.
No. The original is smaller (I'm assuming metric?).
Any Idea what size the original is? It's the head on a Hydramax HM.BIR.01LPT. But usefully the "spares list" on their site doesn't exist despite the link.
http://hydramax.co.uk/
I'd order one off screwfix but it doesn't give connection sizes online.....bloody useful that is.
The house has a fixed showerhead shower. (e.g. not on a hose)
The head a bit rubbish no limescale has got into the wrong places and pushed bits apart.
So down to Focus (I say to focus I mean Homebase(none) to Wicks(none)), we go and buy a new head....
"standard 1/2inch" fitting it says. Excellent thinks I. Only one option must all be the same.
No. The original is smaller (I'm assuming metric?).
Any Idea what size the original is? It's the head on a Hydramax HM.BIR.01LPT. But usefully the "spares list" on their site doesn't exist despite the link.
http://hydramax.co.uk/
I'd order one off screwfix but it doesn't give connection sizes online.....bloody useful that is.
Ferg said:
It's unlikely to be metric, plumbing threads are virtually ALL BSP.
Next size down, 3/8" BSP.
That seems very small, I don't recall one that small. Can you take me a picture??
No picture as I've put it back together and had a hard time getting it to seal. PTFE is my new friend.Next size down, 3/8" BSP.
That seems very small, I don't recall one that small. Can you take me a picture??
But the 1/2" fitting on the "new" head slipped over the thread of the "spout" with just a little space.
I figure I'll just have to phone Hydramax spares line tomorrow and get them to tell me. Might even have to buy one from them as finding one the right fitting could be tricky!
235047 is your part. The link on their site was dodgy.
http://hydramax.co.uk/downloads/HM_BIR.pdf
http://hydramax.co.uk/downloads/HM_BIR.pdf
Edited by Sgt Bilko on Sunday 20th July 12:54
Sgt Bilko said:
235047 is your part. The link on their site was dodgy.
http://hydramax.co.uk/downloads/HM_BIR.pdf
http://hydramax.co.uk/downloads/HM_BIR.pdf
Edited by Sgt Bilko on Sunday 20th July 12:54
Ummm I wonder if they redesigned it because the one I have is s
t?The whole concept of design of these heads is that you are supposed to be able to clean the limescale off them by massaging the smalls nipples
as they are made of latex.
I would recommend ditching both your fixed head nozzle and the fixed stand that holds it to the wall and replace both as a pair. The bit that fixes to the wall is only clamped up with a 15mm olive. Providing your pump can deliver the goods, there are plenty of amazing shower heads out there. I accidentally over-specced our pump to a 4.5 BAR one and the effect when turning it on for the first time can only be described as 'devastating'
To help make this not so violent I went for a Megahead
If you have rotten nipples you are not going to get a good result through that head
as they are made of latex. I would recommend ditching both your fixed head nozzle and the fixed stand that holds it to the wall and replace both as a pair. The bit that fixes to the wall is only clamped up with a 15mm olive. Providing your pump can deliver the goods, there are plenty of amazing shower heads out there. I accidentally over-specced our pump to a 4.5 BAR one and the effect when turning it on for the first time can only be described as 'devastating'
To help make this not so violent I went for a MegaheadIf you have rotten nipples you are not going to get a good result through that head

SS HSV said:
The whole concept of design of these heads is that you are supposed to be able to clean the limescale off them by massaging the smalls nipples
as they are made of latex.
The problem with the head appears to be that limescale has been growing under the latex sheet with nipples. Which means the nipples have retreated into the head, and water is coming arouns the sheet and out the holes in the plastic rather than through the nipples.
as they are made of latex. Basically it's a s