Central heating problem - airlock?
Central heating problem - airlock?
Author
Discussion

maxrider

Original Poster:

2,481 posts

265 months

Thursday 27th November 2008
quotequote all
Had my central heating flushed last week, was ok for a few days but now the upstairs radiators are hot, all downstairs ones cold, I think it might be an airlock but there's so much conflicting advice on google I'm totally confused as to how to clear it.
Have bled all the radiators but no improvement, any (useful) advice welcomed.

tbloke99

236 posts

290 months

Thursday 27th November 2008
quotequote all
How many circ pumps do you have? Is it a duel zone system with upstairs and downstairs thermostats. My downstairs system had zone valves and one had become stuck. See if you can hear the valves opening.
HTH

FWDRacer

3,565 posts

253 months

Thursday 27th November 2008
quotequote all
A few more details of your sytem would help...

maxrider

Original Poster:

2,481 posts

265 months

Thursday 27th November 2008
quotequote all
One pump, one thermostat in hallway.
Sodding plumber is ignoring my messages, at this rate it's going to be a chilly weekend irked

What extra details are needed? I'm a bit of a numpty with plumbing paperbag

Edited by maxrider on Thursday 27th November 11:52

69 coupe

2,459 posts

240 months

Thursday 27th November 2008
quotequote all
Try balancing the rads, they may have been unbalanced when flushing.
http://www.diydata.com/projects/centralheating/bal...

cjs

11,664 posts

280 months

Thursday 27th November 2008
quotequote all
I'm assuming you have a hot water tank? It is not a Combi boiler? Are you getting Hot water?

Try turning off the upstairs rads and see if the downstairs rads get hot?

Is the pump spinning? Maybe it is F88Ked and the hot water is just rising to the upstairs?

If the pump has a dial turn it up full usually 1,2,3.

cjs

11,664 posts

280 months

Thursday 27th November 2008
quotequote all
Why was it flushed? Did you have a problem before?

ln1234

848 posts

227 months

Thursday 27th November 2008
quotequote all
69 coupe said:
Try balancing the rads, they may have been unbalanced when flushing.
http://www.diydata.com/projects/centralheating/bal...
Easy thing to try is to turn off the rads that are working, and see if the other ones get hot. If they do, then they need to be balanced.

Ferg

15,242 posts

286 months

Thursday 27th November 2008
quotequote all
Sounds very like an airlock.
Turn off all rads except one that isn't working.
Make sure pump is on maximum setting.
Select 'Heating' only on the programmer.
Close any bypass valves in the system (if the above doesn't shift it).
Once the rad gets hot, close it and open another non-working one.

King Herald

23,501 posts

245 months

Thursday 27th November 2008
quotequote all
maxrider said:
One pump, one thermostat in hallway.
Sodding plumber is ignoring my messages, at this rate it's going to be a chilly weekend irked

What extra details are needed? I'm a bit of a numpty with plumbing paperbag
This is where I feel far better for paying Homecare insurance...... wink