Electrical wiring (strip lighting) question
Electrical wiring (strip lighting) question
Author
Discussion

NDA

Original Poster:

25,614 posts

254 months

Wednesday 17th December 2008
quotequote all

I'm putting some additional lighting in the garage and note in the instructions with the strip lights (fluorescent tubes) that it says 'this appliance must be earthed'.

In the little connection box within the tube assembly, there's a live and neutral (going to various gubbins within the tube assembly) but the earth connector is connected to nothing - there's no wire that would go from my earth to anywhere. Is this normal?

Thanks

N

sjj84

2,396 posts

248 months

Wednesday 17th December 2008
quotequote all
The earth will be connected to the metal body of the strip light.

ray_von

3,038 posts

281 months

Wednesday 17th December 2008
quotequote all
Wot he said

Ganglandboss

8,547 posts

232 months

Wednesday 17th December 2008
quotequote all
Is it a plastic enclosure or is it a metal one and you have not noticed the little metal tab going into the connector? If it is the former it will not need an earth connection to the case but it must still have somewhere to terminate your earth should you extend the circuit, install a switch wire from it or replace it with a metal bodied fitting in the future.

Dave - qualified spark.

ray_von

3,038 posts

281 months

Wednesday 17th December 2008
quotequote all
and him biggrin

Edited by ray_von on Wednesday 17th December 17:29

NDA

Original Poster:

25,614 posts

254 months

Wednesday 17th December 2008
quotequote all

Guys, you're right. There is a tiny tab - I thought that was to hold the little connector in place.

Feel a bit of twot now.

Thanks for the speedy replies. Let there be LIGHT!


smile

NDA

Original Poster:

25,614 posts

254 months

Wednesday 17th December 2008
quotequote all

PS Dave, just out of interest, if I hadn't earthed the fitting, what happens? Is there a risk of shock or fire? Just curious, I'm not going to do it of course!

Sciroccology

29,908 posts

259 months

Wednesday 17th December 2008
quotequote all
NDA said:
Just curious, I'm not going to do it of course!
Of course you're not.

But if you did, you'd die.

GKP

15,099 posts

270 months

Wednesday 17th December 2008
quotequote all
Sciroccology said:
NDA said:
Just curious, I'm not going to do it of course!
Of course you're not.

But if you did, you'd die.
I think I can safely say he's going to die no matter what he does with the light.


/morbid.

Ganglandboss

8,547 posts

232 months

Wednesday 17th December 2008
quotequote all
NDA said:
PS Dave, just out of interest, if I hadn't earthed the fitting, what happens? Is there a risk of shock or fire? Just curious, I'm not going to do it of course!
The earth (or Circuit Protective Conductor (CPC)) is there to carry fault current should the case become live. A very high current will flow as a result and the protective device (fuse or MCB) will operate and disconnect the supply. If you don't connect it, it may well operate without a problem indefinitely but it sure ain't worth chancing it!

Deva Link

26,934 posts

274 months

Wednesday 17th December 2008
quotequote all
Ganglandboss said:
Is it a plastic enclosure or is it a metal one and you have not noticed the little metal tab going into the connector?
If the little metal tab isn't there then you need to make a connection from the connector block to some metal part of the fitting.

NDA

Original Poster:

25,614 posts

254 months

Thursday 18th December 2008
quotequote all
Deva Link said:
If the little metal tab isn't there then you need to make a connection from the connector block to some metal part of the fitting.
There is a wee tab there.

Thanks for the replies, I was a bit anxious about firing up the light without checking the answer.