Discussion
The battery cable to the starter on the TVR is actually very good spec
An additional (similar quality) Earth cable to the engine block is normally the only additional engineering modification applied to the load side of the starter. Generally achieved a few ways, making sure of good battery chassis grounding and the cable that crosses the engine mount, IIRC Mr Beer has recommended running battery earth to block in the past..
Poor earthing just makes the starter spin slower, it's not the same as the hot start problem which is caused by the solenoid not throwing and engaging those heavy duty cables
An additional (similar quality) Earth cable to the engine block is normally the only additional engineering modification applied to the load side of the starter. Generally achieved a few ways, making sure of good battery chassis grounding and the cable that crosses the engine mount, IIRC Mr Beer has recommended running battery earth to block in the past.. Poor earthing just makes the starter spin slower, it's not the same as the hot start problem which is caused by the solenoid not throwing and engaging those heavy duty cables

IIRC its rated @415A Pete, problem is its a lot of strands, extra flexible (for the tortuous route). As I understand it the 415A is a continuous rating, and the starter will not exceed much more than 600A in extreme moments. According to VWP the extra flexible is also akin to thinwall vs old style cable in terms of insulation material improvements. There may be greater capacity flexible cable, but the TVR original seems to be fit for purpose in my mind, I did originally find the mismatch of 650A CCA and 450A cable a bit disconcerting but others put my mind to rest 
The area that I found of concern was that the engine ground (across the engine mount) was of an inferior battery cable type, I simply replaced this with similar to the battery cable from VWP
whilst I was adding my extra duplex earthing in the nose & dash areas.
The concept of oversizing cables / fuses (no fuses :yikes) to compensate for bad earthing is extremely unsettling to me so I do try & consciously avoid doing it. From my own experience I am sure that with good clean connectors and grounds the TVR wiring is fine

The area that I found of concern was that the engine ground (across the engine mount) was of an inferior battery cable type, I simply replaced this with similar to the battery cable from VWP
whilst I was adding my extra duplex earthing in the nose & dash areas.The concept of oversizing cables / fuses (no fuses :yikes) to compensate for bad earthing is extremely unsettling to me so I do try & consciously avoid doing it. From my own experience I am sure that with good clean connectors and grounds the TVR wiring is fine