Oxygen sensor boss size
Discussion
It seems that the standard TVR sensor has a different size (smaller) boss than the norm. I plan to use a narrow band sensor on one side and a wide band the other for AFR metering. But would like to have the option of swapping sides. I know some of you are doing the same thing so what have you done about the boss size ? Presumably I could change the boss both sides and buy one wide band and one narrow band. I have heard of people using a wide band mounted in the small boss with some sort of adapter, that way I can leave the manifolds standard. Anybody got experience of the adaptor method?
I have a boss for a wideband sensor on both sides. I only use one side and I have a blanking plug in the other. The original narrowband bosses are still in place and have narrowband sensors fitted just to plug the holes. (I assume the sensors are U/S by now but if I had wanted to preserve them I would have put plugs in there too.)