Is this a bodge or an 'improvement'
Is this a bodge or an 'improvement'
Author
Discussion

WokingWedger

Original Poster:

1,030 posts

236 months

Friday 20th March 2009
quotequote all
Whilst searching for my coolant temp sensor (now found) I noticed an inch and a half long cast spigot (hose connection) directly below the throttle pot on the plenum inlet. It comes from a box cast under the inlet tract.

It has nothing connected nor does it appear 'blocked off' (at least no visible cap over the end of the spigot)

I then found what I beleive to be the hose that once connected to it. It was laying under the plenum and had a bolt in the end, held in with a jubille clip.

The other (connected end) attaches to the engine near the temp sender I was looking for.

Can anyone advise what it is ?
Should I reconnect it or block up the spigot.

Also between where this pipe connects to the block and the coolant temp sender there is (what appears to be) a small sender/sensor that has no wires to it.
Again any clues any one ?

blitzracing

6,422 posts

251 months

Friday 20th March 2009
quotequote all
The pipework is the inlet manifold preheat for warming the inlet air from the water jacket. Its blocked off as its generally thought that warm air produces less power than cold (more dense so more oxygen to burn), but is needed in colder climates.

locodude

510 posts

226 months

Friday 20th March 2009
quotequote all
Not sure about the spigot and hose but I think it's redundant on the TVR. The sensor with no wire to it will be the sensor that Rover used for their instruments. The one the Chim uses is behind the distributor and is TVR's own calibrated to their dash gauges. There is a work round to use this sensor I believe, involes putting a resistor in line (not sure what value?).

Pink_Floyd

900 posts

252 months

Friday 20th March 2009
quotequote all
Nothing to worry about, thats how they all left the factory. Does look a bit of a bodge using a bolt to block off a pipe but mine is exactly the same.

WokingWedger

Original Poster:

1,030 posts

236 months

Friday 20th March 2009
quotequote all
Hahaha

good old TVR

Thanks everybody, I shall just tuck the hose back and forget about it then.

spend

12,581 posts

282 months

Friday 20th March 2009
quotequote all
I prefer to link the 2 pipes together, just use one longer piece of pipe if you have both end fittings. Theres always one coming out of the manifold, the flow and the returns vary. Serps have the other end teed off the heater to swan neck by the rocker cover IIRC. Pre-serps off the heater to water pump steel pipe that runs under the inlet manifold. They seem quite useful if you have problems bleeding air out of the coolant as they are easily the highest points when held upright wink

WokingWedger

Original Poster:

1,030 posts

236 months

Saturday 21st March 2009
quotequote all
Billiant bleeding idea (excuse language) hehe