Distributor swap - dunno where I went wrong!
Discussion
Hello all, was a lovely day today so thought I'd whip out the dizzy and put a brand spanking new one from R.P.I in.
Paid attention to position of the rotor arm relative to the dizzy cap and was an easy out and in with the new.
It wouldn't start initially though. Tried small turns of the dizzy housing to adjust advance but still nothing. Was sure I'd got the rotor pointing at the right cylinder at the right time. 10 attempts at starting and I was getting worried!
It eventually spluttered to life and ran for about 5 seconds and then died. I tried again and managed to catch it with some throttle in the engine bay. Would run fine at 2000 plus but every time it was left to idle it would die!
Tried re-adjusting housing position but no good. Got worried and put the old one back in - started and ran fine FIRST TIME!
The new one obviously works just not at idle!!
Wondered if it could be ECU - does it need resetting after a dizzy change?
Not sure where I went wrong - any advice gratefully received!
Personnaly Id get onto RPI first off, they should know all the problems with there distributors--Definately not the ECU, and it does not need a reset for this. Otherwise rotate the engine to TDC and see if the rotor arm points at plug lead one. It should be there or 180' out depending on what part of the cycle it is. Also does the trigger rotor lobe line up with its pickup when number one should be firing at about 8 degrees BTDC. You could try to get a strobe on the engine and see where its firing in relation to tdc and if you can get the strobe to work on the starter it should show up as the static timing setting.
I remember Steve Heath mentioned a dizzy he had where the base plate was so far out of sync with the cap that it was cross-firing between adjacent pins. It ran OK but gave a very variable spark (and resulting top end misfires, fouled plugs etc).
If you new RPI dizzy was set up right this shouldn't be possible, but shows that even with quite serious faults in the dizzy setup the engine can still keep going. It could be in your case that the engine had far too much advance and needed some revs to cope with that, or it could be that the base plate is in the wrong place wrt the dizzy cap and needed some mech advance to bring the contacts into range of the arm.
In that situation I'd start by checking that the new dizzy had been assembled correctly (mech advance mechanism moves freely against the spring, vac advance capsule securely mounted and attached to the base plate) then spin the engine over and see whether it actually produced a spark at the coil (shows the pickup and amp working OK). Then look for a string spark at one of the plug leads and check the timing against the crank pulley. Then see where the rotor arm points when the crank is in that position - does it actually line up with one of the HT leads?
ETA Also check the exact position of the rotor arm relative to the cap - maybe the RPI dizzy requires a different rotor arm / cap combination if the heights are different. A fault here would show up as a strong spark at the king lead but not at the plugs.
If you new RPI dizzy was set up right this shouldn't be possible, but shows that even with quite serious faults in the dizzy setup the engine can still keep going. It could be in your case that the engine had far too much advance and needed some revs to cope with that, or it could be that the base plate is in the wrong place wrt the dizzy cap and needed some mech advance to bring the contacts into range of the arm.
In that situation I'd start by checking that the new dizzy had been assembled correctly (mech advance mechanism moves freely against the spring, vac advance capsule securely mounted and attached to the base plate) then spin the engine over and see whether it actually produced a spark at the coil (shows the pickup and amp working OK). Then look for a string spark at one of the plug leads and check the timing against the crank pulley. Then see where the rotor arm points when the crank is in that position - does it actually line up with one of the HT leads?
ETA Also check the exact position of the rotor arm relative to the cap - maybe the RPI dizzy requires a different rotor arm / cap combination if the heights are different. A fault here would show up as a strong spark at the king lead but not at the plugs.
Edited by GreenV8S on Monday 13th April 23:35
Quinny said:
Leave the old one in and get your money back
Seriously though. Were you changing it for a reason? Or just cos you fancied a new one.
After a motorway run I get a lump at around 2000 that feels like a stuck mechanical advance weight. Was swapping over to see if new dizzy cured it.
Seriously though. Were you changing it for a reason? Or just cos you fancied a new one.
Did lube up and clean the old one before it went back in so I'll see what it's like after another hoon up the M5!
Edited by debaron on Tuesday 14th April 11:08
Edited by debaron on Tuesday 14th April 11:10
Gassing Station | Chimaera | Top of Page | What's New | My Stuff