1995 500 twin fans problem
1995 500 twin fans problem
Author
Discussion

Slacey

Original Poster:

1,113 posts

243 months

Sunday 14th June 2009
quotequote all
Firstly, the search is still down wink

I had a problem on Friday in that after a long journey in traffic and heat, I thought the fans didn't sound right when running. Investigation revealed that only one was working. I have had a problem with one fan not long after getting the car, but it appeared to be a loose connection in the connector one the one fan, easily sorted. Two years later it's the same one that's gone, however this time the connector looked burnt and had melted slightly. After struggling to part the halves, I plugged the non working fan into the working one's power connector and bingo, fan runs, so it isn't knackered. I got a multimeter on the other connector and nothing.
So, the question is - I am pretty sure I have only 1 40a fuse and 1 relay for both fans (as evident on my fuse board), but there are 4 wires splitting 2 connectors, one for each fan. Do both sets of wires eventually become one at the relay, or am I missing something? As a quick fix I have wired both fans to the one working connector and it seems OK, no popped fuses or welded relays. I'd rather get it back to the way it was though, thoughts?
As a last note I sprinted the car at Abingdon on the Saturday, and although I only had one fan the car ran fine, never getting anywhere near too hot - the one fan was working hard though!

Ant.

5,254 posts

310 months

Monday 15th June 2009
quotequote all
Sean, double check your fuse box, pretty sure all the twin fan cars had twin relays.

Colin RedGriff

2,541 posts

286 months

Monday 15th June 2009
quotequote all
My 1996 500 has twin relays and twin fuses (although one of them had been changed to 40a at some point. Check the earth wire for the fans as well.

Slacey

Original Poster:

1,113 posts

243 months

Monday 15th June 2009
quotequote all
OK chaps, just checked again and I'm sure there is only one fuse / relay. The layout matches the handbook, which only lists one of each too. See the pic below:



The fan relay is the yellow one top left. I have pulled each of the others to check they operate what the handbook says they do and all check out OK. The 40a fuse is the first one on the left, again the only one marked for fans.

Below is the mess hanging off the main loom - the only two relays on here are the two regular silver ones.



As for the earth, which one is it, the one by the radiator? Also, if that was dodgy would in not affect both power feeds? Thanks for the info so far smile


Colin RedGriff

2,541 posts

286 months

Monday 15th June 2009
quotequote all
Ah your fusebox is different to mine - I have another relay below the brown one.

On mine (yours may be different), each of the fans has a connector, with a live feed and earth, which are separate. Easy enough to check just make up a short lead and connect it in place of the existing earth and then earth it.

Ant.

5,254 posts

310 months

Monday 15th June 2009
quotequote all
Sean, seperate the two supplies at the fans and check for power. At least that will prove the wiring to the fans.

Slacey

Original Poster:

1,113 posts

243 months

Monday 15th June 2009
quotequote all
Do you mean take the live from the knackered one and the earth from the good one to check for power?
Both fans work when connected to the one good supply, which shows 12v on the meter, the other supply is dead.

Edited by Slacey on Monday 15th June 21:13