I have a ceiling light, like the one below, in the kitchen. Mine has normal R50 40watt spotlight bulbs though - 4 of them - not halogens like in the pic. But the mounting etc is the same style.



My problem is that 2 of the 4 bulbs keep blowing after only a couple of uses - the same bulbs each time. Whereas the other 2 plough on as normal.

Does anyone know a reason why this would keep happening?

Thanks

philthy

4,697 posts

253 months

Thursday 12th November 2009
quotequote all
We had some similar fittings in the shop I used to have. They would pop regularly, and all we could put it down to, was vibration from people running about on the floor above the fitting?

phil1979

Original Poster:

3,620 posts

228 months

Thursday 12th November 2009
quotequote all
philthy said:
We had some similar fittings in the shop I used to have. They would pop regularly, and all we could put it down to, was vibration from people running about on the floor above the fitting?
Nice idea, but the room above is vacant, so it wouldn't be that.

speedyman

1,588 posts

247 months

Thursday 12th November 2009
quotequote all
Rubbish batch of replacement lamps, move the good lamps to the suspect fittings and see if they blow. Check connections are tight (switch power off first).

Speedyman


Fastra

4,286 posts

222 months

Thursday 12th November 2009
quotequote all
philthy said:
We had some similar fittings in the shop I used to have. They would pop regularly, and all we could put it down to, was vibration from people running about on the floor above the fitting?
biggrin

We had exactly the same thing.
Ours is in the kitchen below my daughters bedroom, so her daughter dancing about would cause the whole thing to flash on and off - I regularly have to tighten the fittings! The screw in bulbs often work themselves loose after a while too - like a bloody herd of elephants she is!!

smile

hairyben

8,516 posts

196 months

Thursday 12th November 2009
quotequote all
Probably the contacts in the lampholder aren't touching properly, there's a centre contact that may be too far back and a side contact that may be too far out. General wear and irregularities between lamps. This can normally be fixed by prising/bending them forward a few mm with a screwdriver/long nose pliers, once of course the fitting is dead and safe to work on.

eps

6,494 posts

282 months

Thursday 12th November 2009
quotequote all
The life on the bulbs used are usually quite low as well... The more expensive/low e ones are usually better rated.

We've got a similar light fitting and they go quite often, but then again they are on quite a bit. I won't be buying such