Any boiler experts here (Glow Worm code F1)?
Any boiler experts here (Glow Worm code F1)?
Author
Discussion

paddyhasneeds

Original Poster:

63,662 posts

232 months

Saturday 13th March 2010
quotequote all
Our boiler (a Flexicom HX) has just making a bubbling/boiling sound and has the "F1" error code on the LCD, pressing the reset button has no effect.

We've turned off the heating at the timer unit and British Gas will be out tomorrow - just curious if anyone has any knowledge of these as to what it might be?

Thanks.

Ferg

15,242 posts

279 months

Saturday 13th March 2010
quotequote all
F1 is a lockout.
In my experience it's been a failure of the flame rectification circuit often dirty ignition electrodes, but it could be anything from a gas failure to a blocked condensate trap.

Edited to add, I thought you could reset that. Off and On at the wall?

Edited by Ferg on Saturday 13th March 17:09

paddyhasneeds

Original Poster:

63,662 posts

232 months

Sunday 14th March 2010
quotequote all
Ferg said:
F1 is a lockout.
In my experience it's been a failure of the flame rectification circuit often dirty ignition electrodes, but it could be anything from a gas failure to a blocked condensate trap.

Edited to add, I thought you could reset that. Off and On at the wall?

Edited by Ferg on Saturday 13th March 17:09
Blocked condensate trap as it turns out. One of those things that once you see the gas man take it apart and clean it you think "Doh!" but at the same time we pay for cover so I'm not about to start taking it to pieces.