Expansion tank
Discussion
I have noticed since owning my 4 litre chimaera for the last year that the water in the expansion tank is always at the bottom,you can fill it up and the next time you come to the car and check the water its at the bottom again.I recently fitted a new ali rad and act hoses,and it still does it.I have had a pressure test done and it holds perfect pressure.Wheres the water going,the car runs well and doesnt over heat whatsoever.
It may come out of the cap but as the heat in the engine bay is so great it may well evaporate all signs.
I used to top mine up about half way, now I peer in and as long as the water level (when cold) is just above the pipe at the bottom I leave it, it'll only expand in to the space from there.
I used to top mine up about half way, now I peer in and as long as the water level (when cold) is just above the pipe at the bottom I leave it, it'll only expand in to the space from there.
wongthecorrupter said:
scotty_d said:
I would still keep a close eye on it till your happy its just they way your is and no l
eaking issues and worth nipping up all the new silicon hoses they do settle in a bit.
Will do cheerseaking issues and worth nipping up all the new silicon hoses they do settle in a bit.
I've had a couple of posts on this in the past as it worried me too... and have since discovered something else on the subject!
I've had the car since 2008 when it would run and hold about 1/2 way up the tank. Over winter I changed the rad and replaced it with a 3 core unit so more fluid... it then went down to 33mm using a 1.3 bar cap... I assumed more water, more expansion.
This winter I've had a new cam fitted and found on its return that it was running on the bottom of the tank. So having gone around all the clips and found 1 loose and one very loose, I tightened them up. I filled the bottle to 60mm to compensate for any air still to come out expecting next time I checked that it would be sat at 33mm... wrong.. It’s still at 60mm after 250 miles or so and nothing like the pressure it was last year.
Conclusion.
1 The level is indicative of the weakest joint then cap pressure... so if your pipes release pressure (but not ness leak all the time).. it will find its level relative to this... it may equate to say 1/2 bar.. but will then sit there and work quite happily.
2 Even though I filled the system a few times last year ( the rad came out more than once!!) and bleed the thing, I'd obviously still got an air trap... I think it was in the heater matrix, but this must have been presurising the system and causing fluid to blow out... very accurate as it always sat at 33mm... since getting this bubble out the system pressure is less, the heater is warmer (FFS!) and I'm sure if I filled it up now, it would settle back to its 1/2 tank mark or even higher.
So if your running on the bottom of the tank and you system is sound... it's either a joint acting like the cap and releasing fluid / pressure to what ever it seals at... or you have trapped air.
try take the heater hoses off and fill that first.. although I did this last year and obviously still didn't shift it... you can take them off in the footwell.
.. may be worth a try!!.. good luck!


I've had the car since 2008 when it would run and hold about 1/2 way up the tank. Over winter I changed the rad and replaced it with a 3 core unit so more fluid... it then went down to 33mm using a 1.3 bar cap... I assumed more water, more expansion.
This winter I've had a new cam fitted and found on its return that it was running on the bottom of the tank. So having gone around all the clips and found 1 loose and one very loose, I tightened them up. I filled the bottle to 60mm to compensate for any air still to come out expecting next time I checked that it would be sat at 33mm... wrong.. It’s still at 60mm after 250 miles or so and nothing like the pressure it was last year.

Conclusion.
1 The level is indicative of the weakest joint then cap pressure... so if your pipes release pressure (but not ness leak all the time).. it will find its level relative to this... it may equate to say 1/2 bar.. but will then sit there and work quite happily.
2 Even though I filled the system a few times last year ( the rad came out more than once!!) and bleed the thing, I'd obviously still got an air trap... I think it was in the heater matrix, but this must have been presurising the system and causing fluid to blow out... very accurate as it always sat at 33mm... since getting this bubble out the system pressure is less, the heater is warmer (FFS!) and I'm sure if I filled it up now, it would settle back to its 1/2 tank mark or even higher.
So if your running on the bottom of the tank and you system is sound... it's either a joint acting like the cap and releasing fluid / pressure to what ever it seals at... or you have trapped air.

try take the heater hoses off and fill that first.. although I did this last year and obviously still didn't shift it... you can take them off in the footwell.
.. may be worth a try!!.. good luck!
My normal level is only about 2" above the bottom of the expansion tank.
If you think its going out of the pressure cap just wrap some cloth/tissue around the expansion tank and use the car for a few days . The rag/ tissue will show signs of coolant. It you are still bothred you could always change the rad cap for a new one. if it is always the same level then I wouldnt worry.
If you had a leak then the coolant loss would be continuous
If you think its going out of the pressure cap just wrap some cloth/tissue around the expansion tank and use the car for a few days . The rag/ tissue will show signs of coolant. It you are still bothred you could always change the rad cap for a new one. if it is always the same level then I wouldnt worry.
If you had a leak then the coolant loss would be continuous
.Mark said:
It may come out of the cap but as the heat in the engine bay is so great it may well evaporate all signs.
I used to top mine up about half way, now I peer in and as long as the water level (when cold) is just above the pipe at the bottom I leave it, it'll only expand in to the space from there.
What about fixing some cloth over the cap and then going for a run. It water is coming out through the cap I would expect the clothI used to top mine up about half way, now I peer in and as long as the water level (when cold) is just above the pipe at the bottom I leave it, it'll only expand in to the space from there.
to be at least damp.
OTOH, I could be talking out my XRSX!
The clue is in the name 'Expansion tank'. Where is it going to expand to if the tank is full! The PH collective have always said that filling it 50% may be too much. I run mine at 1/3 when cold. Trial and error got me to that setting. At 50% cold level I was still pushing small quantities out in extreme circumstances, queuing traffic on a hot, that sort of thing. Water increases in volume as it gets hotter. The increased volume needs to go somewhere. If you over fill the expansion tank then it will hydraulically lift the pressure cap and drain to the floor. Once it has done that the next time you check the cold level it will be low. That's what it's supposed to do.
bsdnazz said:
.Mark said:
It may come out of the cap but as the heat in the engine bay is so great it may well evaporate all signs.
I used to top mine up about half way, now I peer in and as long as the water level (when cold) is just above the pipe at the bottom I leave it, it'll only expand in to the space from there.
What about fixing some cloth over the cap and then going for a run. It water is coming out through the cap I would expect the clothI used to top mine up about half way, now I peer in and as long as the water level (when cold) is just above the pipe at the bottom I leave it, it'll only expand in to the space from there.
to be at least damp.
OTOH, I could be talking out my XRSX!

.Mark said:
It may come out of the cap but as the heat in the engine bay is so great it may well evaporate all signs.
I used to top mine up about half way, now I peer in and as long as the water level (when cold) is just above the pipe at the bottom I leave it, it'll only expand in to the space from there.
+1 - I have a recored rad and all new silicon pipes and s/s swan next. Level was about 1cm above bottom before... and its the same now.I used to top mine up about half way, now I peer in and as long as the water level (when cold) is just above the pipe at the bottom I leave it, it'll only expand in to the space from there.
After the new rad wss fitted I had small amounts f air finding their way out for a while. I was checking the swirl pot for a few days every morning when cold and adding a cm or two of fluid each time. Must have all come out as I've checked the swirl pot since and its been brim full every time.
I tried a new blue cap (a genuine one not ebay special) and it didnt seem to fit properly compared to the old one and wasnt holding the pressure properly so I changed it back.
Gassing Station | Chimaera | Top of Page | What's New | My Stuff