NOT fuel pump relays - pump next????
Discussion
Latest update - I have checked the fuel pump isolator switch, renewed fuel pump relays(2 no),cleaned terminals on fuel pump, disconnected and reconnected battery to reset alarm/immobiliser and....ZIPPO - still no power to pump!! dont even have any TVR expertise nearby, so getting real pissed off...

robertp said:
Latest update - I have checked the fuel pump isolator switch, renewed fuel pump relays(2 no),cleaned terminals on fuel pump, disconnected and reconnected battery to reset alarm/immobiliser and....ZIPPO - still no power to pump!! dont even have any TVR expertise nearby, so getting real pissed off...
In my very humble opinion there are two alternatives.
One, the power to the pump is still being inhibited by the alarm.
Two, you have a break in the supply - provided you did measure 12v leaving the inertia switch (did you measure, or just waggle with a finger whilst up-side-down)??
The solution, to ensure pump is OK, is to wire a separate (fused) wire from battery to the pump - If this then works, you will have to decide on further fault finding to ascertain where problem lies, but bet its either 1 or 2.
Keep smiling.
Trev McM
Gassing Station | Chimaera | Top of Page | What's New | My Stuff



I suppose I need to look at the pump next and try a direct feed, eh? So where do I find the pump and what else should i try?