Coil pack location
Discussion
Where have you guys fitted yours?
Does anyone know where i can get one of these http://thumbsnap.com/ZKQbiIEp (borrowed from another thread)
Does anyone know where i can get one of these http://thumbsnap.com/ZKQbiIEp (borrowed from another thread)
Ask Fordy if he'll do you a bracket - they just mount across the front of the plenum which seems to create a good angle for leads and easy to cross banks etc.
That's a cut down dizzy, explained the process somewhere on here in the last few months (maybe engines / mods). Just finished with a screw on ally cap IIRC.
That's a cut down dizzy, explained the process somewhere on here in the last few months (maybe engines / mods). Just finished with a screw on ally cap IIRC.
spend said:
Ask Fordy if he'll do you a bracket - they just mount across the front of the plenum which seems to create a good angle for leads and easy to cross banks etc..
I was thinking the same but mounted on one of these http://trigger-wheels.com/store/contents/en-uk/d11... ive seen a few positioned above the drivers side rocker cover but that means moving the power steering pot

spend said:
That's a cut down dizzy, explained the process somewhere on here in the last few months (maybe engines / mods). Just finished with a screw on ally cap IIRC.
So what are the options other than chopping the dizzy?
SILICONE KID said:
I fitted one each side then removed the dizzy and relocated the power steering tank .Made a simple bracket for the power steering tank out of one of these..simple but works
The second photo shows the coil pack just above the manifold - its going to get pretty hot thereDid V8D put the packs there or yourself?
Meatball said:
So what are the options other than chopping the dizzy?
Many just pull the dizzy & bung the hole.. Unfortunately not all the serps have cam retainers so effectively you have very little holding the cam in only really the chain. If you have a pre-serp you won't have an oil pump anymore 
Unless you are sure the cam is retained I'd always cut the dizzy down personally.
spend said:
Meatball said:
So what are the options other than chopping the dizzy?
Many just pull the dizzy & bung the hole.. Unfortunately not all the serps have cam retainers so effectively you have very little holding the cam in only really the chain. If you have a pre-serp you won't have an oil pump anymore 
Unless you are sure the cam is retained I'd always cut the dizzy down personally.

SILICONE KID said:
No V8d did not do the install.The coil pack seems pritty cool ,had a good feel around and no problems up to yet ..
It wasent a dig, just a question, because your packs are either side of the alternator are your ht leads crossing over each other?Yes crossing over, The leads seem to be very long .I have just made a better heat shield just as a precaution. The other side is mounted above a Steve Heath heat shield .Think mine is a one off as i have two wide band lalmbda sensors , One for each bank .
Ant. You may have problems in the future .Its going to be a bit of a job to get to them and water from your screen will be pouring all over your coil packs .


Ant. You may have problems in the future .Its going to be a bit of a job to get to them and water from your screen will be pouring all over your coil packs .


Edited by SILICONE KID on Sunday 15th August 00:17
Edited by SILICONE KID on Sunday 15th August 00:28
SK, there's no issues with water running over the coil packs in Ant's location.
I've been running P38 coil pack fitted in same location as Ant's (supplied on bracket that fits onto inlet manifold) for 20k miles and no issues.
Easy to get too when I need too and the neatest solution IMO.
Still not sure why anyone would want to go for anything else, lot's of good work locating other coil packs etc, but what's the advantages of running Ford items or anything else for that matter over a P38 packs ? Is it just cost ? Mine was second hand and no issues so far . . .
I've been running P38 coil pack fitted in same location as Ant's (supplied on bracket that fits onto inlet manifold) for 20k miles and no issues.
Easy to get too when I need too and the neatest solution IMO.
Still not sure why anyone would want to go for anything else, lot's of good work locating other coil packs etc, but what's the advantages of running Ford items or anything else for that matter over a P38 packs ? Is it just cost ? Mine was second hand and no issues so far . . .
Johno said:
SK, there's no issues with water running over the coil packs in Ant's location.
I've been running P38 coil pack fitted in same location as Ant's (supplied on bracket that fits onto inlet manifold) for 20k miles and no issues.
Easy to get too when I need too and the neatest solution IMO.
I have a set of P38 to fit next year when I intend fitting megasquirt, but did have concerns that water on the coil packs might be a problem, but good to hear that others have not had a problem.I've been running P38 coil pack fitted in same location as Ant's (supplied on bracket that fits onto inlet manifold) for 20k miles and no issues.
Easy to get too when I need too and the neatest solution IMO.
Did wonder about making a shield so that they wouldn't get wet, do you think that there is any point.?
Lot's did, lots didn't...
How accurate the external balancing is anyway is the million dollar question
If any parts have been swapped or the like it may not even still be at the factory tolerances???
I'm pretty sure you can't see the cam retainer through the dizzy hole - its nestled behind the cam gear..
How accurate the external balancing is anyway is the million dollar question
If any parts have been swapped or the like it may not even still be at the factory tolerances??? I'm pretty sure you can't see the cam retainer through the dizzy hole - its nestled behind the cam gear..
Gassing Station | Chimaera | Top of Page | What's New | My Stuff













